Design and testing of thin-film temperature sensors integrated on harmonic reducer

  • role: First author第一作者
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

  • Email:csx2000820@163.com
  • Introduction:曹嘉鋆(2000-),女,江苏泰州人,硕士研究生,2022年于西安理工大学获得学士学位,主要从事机器人关节温度测量方面的研究。 E-mail: csx2000820@163.com
CAO Jiajun,  
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

SHEN Wenqiang,  
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

WANG Xiaodong,  
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

YANG Jinyi,  
  • role: Corresponding author通信作者
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

  • Email:louzf@dlut.edu.cn
  • Introduction:娄志峰(1978-),男,黑龙江肇东人,副教授,1999年、2008年于大连理工大学分别获得学士和博士学位,研究方向为微小组件自动装配技术、数控机床误差测量与补偿技术等。E-mail: louzf@dlut.edu.cn
LOU Zhifeng*

ملخص

جمع بيانات درجة الحرارة في وقت حقيقي أثناء عمل مخفض التروس ومراقبتها يساعد على تشخيص الأعطال بسرعة وتحسين الأداء، لذا تمت مقترحة جهاز استشعار حراري رقيق مدمج في داخل مخفض التروس. من أجل تقليل تأثير تحميل مرن العجلة على دقة جهاز استشعار الحرارة أثناء عمل مخفض التروس، تم تحليل نمط التحميل باستخدام طريقة العناصر المحدودة في حالات عمل مختلفة لمخفض التروس، وتم تصميم هيكل جهاز استشعار الحرارة الرقيقة لتقليل تأثير التحميل على قياس الحرارة. تم تحضير جهاز استشعار الحرارة الرقيقة باستخدام تقنية MEMS، وتم تعويض تأثير التحميل على الحرارة، وتم اختبار أداء قياس الحرارة للجهاز الاستشعار. أظهرت نتائج الاختبار أن دقة قياس الحرارة الثابتة لجهاز استشعار الحرارة الرقيقة هي ± 0.30٪، والدقة الديناميكية لقياس الحرارة هي ± 0.52٪. تم إعادة اختبار أداء قياس حرارة جهاز الاستشعار الحراري المحلي، وفي درجة حرارة تتراوح بين 20 و 120 درجة مئوية، كانت الانحراف المعياري مقارنة بجهاز الاستشعار الحراري القياسي هو 0.072-0.296 درجة مئوية، مما أدى إلى جمع إشارة درجة حرارة العمل في مخفض تروس في الوقت الحقيقي.

مفهوم

temperature sensor;harmonic reducer;finite element analysis;integrated sensor

References

  1. 1.
    ZHANG Q, NIU L ZH, FAN Y N, et al. Design of robot joint torque measurement sensor[J]. Chinese Journal of Sensors and Actuators, 2020, 33(4): 506-510. (in Chinese). doi:
  2. 2.
    PERRONE M, MELL S P, MARTIN J, et al. Machine learning-based prediction of hip joint moment in healthy subjects, patients and post-operative subjects[J]. Computer Methods in Biomechanics and Biomedical Engineering, 2025, 28(7): 1093-1097. doi:
  3. 3.
    LI X H, LIU J K, WANG SH. Transmission performance test of harmonic gear lubricated with 601EF grease under vacuum thermal cycling environment[J]. Spacecraft Environment Engineering, 2011, 28(5): 450-453. (in Chinese)
  4. 4.
    WANG Y H, LIU J H, GUAN E G, et al. Analysis of fatigue failure characteristics of harmonic reducer[J]. Machine Tool & Hydraulics, 2021, 49(23): 159-164. (in Chinese)
  5. 5.
    QU B, LI ZH, GUO X, et al. Accuracy of the strain gauge torque sensor influenced by temperature and the measured value correction[J]. Electrical Machinery Technology, 2020(5): 59-61. (in Chinese)
  6. 6.
    ZHAO Y Y, LI P X, DING H L, et al. Harmonic reducer performance prediction algorithm based on multivariate state estimation and LargeVis dimensionality reduction[J]. IEEE Access, 2023, 11: 126762-126774. doi:
  7. 7.
    PEREZ-DIAZ J, DIEZ-JIMENEZ E, VALIENTE-BLANCO I, et al. Performance of magnetic-superconductor non-contact harmonic drive for cryogenic space applications[J]. Machines, 2015, 3(3): 138-156. doi:
  8. 8.
    VASSILEVA D, KIYOSAWA Y, SUZUKI M. Sensorless torque control for a robot with harmonic drive reducers[J]. Mechanics Based Design of Structures and Machines, 2011, 39(2): 253-267. doi:
  9. 9.
    SHI Y, YIN H CH, LI J Y, et al. Modeling and parameter identification of friction characteristics of harmonic reducer[J]. Journal of Northeastern University (Natural Science), 2022, 43(1): 89-96, 110. (in Chinese)
  10. 10.
    XU D, ZHANG L,LUO ZH L. A device for temperature detection of flexible gears in harmonic reducers: CN112432710A [P]. 2021-03-02. (in Chinese).
  11. 11.
    DOLBIER W R, BEACH W F. Parylene-AF4: a polymer with exceptional dielectric and thermal properties[J]. Journal of Fluorine Chemistry, 2003, 122(1): 97-104. doi:
  12. 12.
    YAN W P, LI H N, LIU J S, et al. EPMA and XRD study on nickel metal thin film for temperature sensor[J]. Sensors and Actuators A: Physical, 2007, 136(1): 212-215. doi:
  13. 13.
    XU J, SHAO T M, JIN G. Effect of processing conditions on microstructure and electrical characteristics of Ni thin films[J]. Vacuum, 2009, 84(4): 478-482. doi:
  14. 14.
    MA B H, REN J Z, DENG J J, et al. Flexible thermal sensor array on PI film substrate for underwater applications[C]. 2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS). January 24-28, 2010. Wanchai, Hong Kong, China. IEEE, 2010: 679-682.
  15. 15.
    PHATTHANAKUN R, DEEKLA P, PUMMARA W, et al. Design and fabrication of thin-film aluminum microheater and nickel temperature sensor[C]. 2012 7th IEEE International Conference on Nano/Micro Engineered and Molecular Systems (NEMS). March 5-8, 2012. Kyoto, Japan. IEEE, 2012: 112-115.
  16. 16.
    TURKANI V S, NARAKATHU B B, MADDIPATLA D, et al. Nickel based printed resistance temperature detector on flexible polyimide substrate[C]. 2018 IEEE SENSORS. October 28-31, 2018. New Delhi. IEEE, 2018: 1-4. doi:
  17. 17.
    CUI J T, LIU H, LI X L, et al. Fabrication and characterization of nickel thin film as resistance temperature detector[J]. Vacuum, 2020, 176: 109288. doi:
  18. 18.
    RODGER D C, LI W, AMERI H, et al. Flexible parylene-based microelectrode technology for intraocular retinal prostheses[C]. 2006 1st IEEE International Conference on Nano/Micro Engineered and Molecular Systems. January 18-21, 2006. Zhuhai, China. IEEE, 2006: 743-746.
  19. 19.
    WANG X D, DU ZH J, SHEN W Q, et al. Design and testing of harmonic reducer integrated with torque sensor[J]. Optics and Precision Engineering, 2024, 32(19): 2899-2910. (in Chinese). doi:
  20. 20.
    GAO H L, SHEN W Q, DU ZH J, et al. Development of integrated torque sensor for harmonic reducer and Error Compensation[J]. Opt. Precision Eng., 2024, 32(12): 1857-1867. (in Chinese). doi: