تحقيق المعايرة المطلقة لتداخل معدل الضوء المكاني بالبلورات السائلة باستخدام شبكة مزدوجة

  • role: First author第一作者
  • Affiliation:

    College of Electromechanical Engineering and Automation, Shanghai University, Shanghai 200444, China

  • Email:guofengzhang@shu.edu.cn
  • Introduction:张国峰(1999-),男,河北石家庄人,博士研究生,2022年于河南科技大学获得学士学位,主要从事光学成像与融合传感等方面的研究。E-mail: guofengzhang@shu.edu.cn
ZHANG Guofeng1,  
  • Affiliation:

    National Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China

ZHANG Junyong2,  
  • role: Corresponding author通信作者
  • Affiliation:

    College of Electromechanical Engineering and Automation, Shanghai University, Shanghai 200444, China

  • Email:wangchi@shu.edu.cn
  • Introduction:王 驰(1982-),男,河南太康人,博士,教授,2009年于天津大学获得博士学位,主要从事应用光学与融合传感测试技术等方面的研究。E-mail:wangchi@shu.edu.cn
WANG Chi1*

ملخص

يتمتع معدل الضوء المكاني بالبلورات السائلة (معدلات الضوء المكاني بالبلورات السائلة، LC-SLM) بإمكانات كبيرة للتطوير في مجالات مثل التحكم بمجال الضوء، لكن خرج الطور غير المعاير لجهاز SLM يكون غير منتظم ويتأثر بشروط التجربة والعوامل البيئية، مما يصعب التحكم بدقة تعديل الطور. لذلك، قمنا في هذا البحث بإجراء اختبار معاير دقيق لهذا المعدل لضمان تطبيق ثابت ودقيق في المجالات ذات الصلة. بناءً على مبدأ فيرما ومبدأ هوينجز-فريلان، تم دمج الشبكة والشبكة الحاملة للحزوز البصرية لتشكيل عنصر بصري حيودي (DOE). باستخدام زوج من الشبكات لإنتاج ثلاث نقاط بؤرية، يتداخل النقطة البؤرية الوسطى لتكوين خطوط تداخل، بينما تبني الحزم الأخرى نظام إحداثي مطلق لتحديد نقطة مرجعية لحركة الخطوط. استخدمنا شبكة عصبية U-Net لمعالجة صور خطوط التداخل مسبقًا، واستخرجنا مراكز الكتلة الرئيسية عبر الكشف عن المحيط وخوارزمية مركز الكتلة، وتم تحديد تأخير الطور من حساب إزاحة الخطوط ودورتها. أخيرًا، قمنا ببناء نظام معايرة الطور الذي يشمل مصدر ضوء عالي التماسيم، مقسم شعاع، LC-SLM، شبكة مقسم شعاع وكاميرا CCD لإجراء التجارب. أظهرت النتائج التجريبية أن خطوط التداخل تحركت بشكل ملحوظ مع تغير قيمة الرمادي أثناء تحميل تسلسل تعديل الرمادي المختلفة، وتم الحصول بنجاح على منحنى استجابة الطور-الرمادي. كانت نتائج التوفيق متوافقة مع النظرية بشكل أساسي، حيث وصل معامل التحديد R² إلى 0.9851، وخطأ الجذر التربيعي المتوسط (RMSE) إلى 0.2411 راديان، ولا يزال النظام يحافظ على R²>0.95 تحت اضطراب المروحة مع زيادة RMSE فقط قدرها 0.14 راديان، مما يثبت متانة الطريقة وقدرتها على مقاومة التداخل. توفر طريقة المعايرة الدقيقة للطور لجهاز LC-SLM المبنية على مزدوج الشبكة لإنشاء نظام إحداثي مكاني مطلق حلاً موثوقًا يعالج متطلبات الاستقرار العالية وأساليب المعايرة التقليدية التي تعاني من التأثر بالتداخل وضعف الدقة.

مفهوم

معدل الضوء المكاني بالبلورات السائلة;المعايرة المطلقة للتداخل;تشتت الشبكة;مقاومة الاهتزاز;شبكة عصبية U-Net

References

  1. 1.
    LI C, XIA M L, MU Q Q, et al. High-precision open-loop adaptive optics system based on LC-SLM[J]. Optics Express, 2009, 17(13): 10774-10781. doi:
  2. 2.
    CHEN B, LI X Y, YANG X. Phase grating wavefront curvature sensor based on liquid crystal spatial light modulator[C]. 2015 International Conference on Optical Instruments and Technology: Optical Sensors and Applications. Beijing, China. SPIE, 2015: 962015. doi:
  3. 3.
    ZHOU Y, LI R Z, YU X H, et al. Progress in study and application of optical field modulation technology based on liquid crystal spatial light modulators (invited)[J]. Acta Photonica Sinica, 2021, 50(11): 9-40. (in Chinese)
  4. 4.
    YANG Q H, LI P, YANG H, et al. Generation of high-order and fractional vortex beams using gratings simulated by spatial light modulators[J]. Optics and Precision Engineering, 2023, 31(19): 2809-2817. (in Chinese). doi:
  5. 5.
    LI ZH, MU Y, LIANG J Y, et al. Application of LC-SLM in adaptive optics[J]. Study on Optical Communications, 2024(2): 80-91. (in Chinese)
  6. 6.
    SHEN X L, KAHN J M, HOROWITZ M A. Compensation for multimode fiber dispersion by adaptive optics[J]. Optics Letters, 2005, 30(22): 2985. doi:
  7. 7.
    WEI Y, YU Y H, HEI X B, et al. Application of vortex beam and photon counting in underwater optical communication[J]. Laser & Optoelectronics Progress, 2022, 59(13): 95-100. (in Chinese). doi:
  8. 8.
    XU ZH B, WANG SH Y, LIU W CH, et al. Multifocal Fresnel lens based on liquid crystal spatial light modulator[J]. Optics and Precision Engineering, 2016, 24(10s): 156-161.(in Chinese)
  9. 9.
    TANG M Y, WU M T, ZANG R H, et al. Fresnel incoherent digital holography with large field-of-view[J]. Acta Physica Sinica, 2019, 68(10): 99-104. (in Chinese). doi:
  10. 10.
    TIWARI V, GAUTAM S K, NAIK D N, et al. Characterization of a spatial light modulator using polarization-sensitive digital holography[J]. Applied Optics, 2020, 59(7): 2024. doi:
  11. 11.
    REMULLA K I T, HERMOSA N. Spatial light modulator phase calibration based on spatial mode projection[J]. Applied Optics, 2019, 58(21): 5624-5630. doi:
  12. 12.
    REICHELT S. Spatially resolved phase-response calibration of liquid-crystal-based spatial light modulators[J]. Applied Optics, 2013, 52(12): 2610-2618. doi:
  13. 13.
    ZHANG H X, ZHANG J, WU L Y. Evaluation of phase-only liquid crystal spatial light modulator for phase modulation performance using a Twyman-Green interferometer[J]. Measurement Science and Technology, 2007, 18(6): 1724. doi:
  14. 14.
    ZHENG M J, DU Y L, HUANG S T, et al. Incoherent self-interference digital holographic imaging under structured light illumination[J]. Opto-Electronic Engineering, 2022, 49(7): 74-82. (in Chinese)
  15. 15.
    MAHMUD M S, NAYDENOVA I, TOAL V. Implementation of phase-only modulation utilizing a twisted nematic liquid crystal spatial[J]. Journal of Optics A: Pure and Applied Optics, 2008, 10(8): 085007. doi:
  16. 16.
    WANG C, SHAN J, ZHANG J Y. Absolutely interferometric calibration of phase liquid crystal spatial light modulators using honeycomb gratings composited with Billet-split Fresnel zone plates[J]. Applied Optics, 2024, 63(4): 1105. doi:
  17. 17.
    RONNEBERGER O, FISCHER P, BROX T. U-Net: convolutional networks for biomedical image segmentation[C]. Medical Image Computing and Computer-Assisted Intervention-MICCAI 2015. Cham: Springer, 2015: 234-241. doi:
  18. 18.
    WANG F M, ZHANG Y H, HUANG W, et al. Calibration of LC-SLM with strip grating phase image[J]. Infrared and Laser Engineering, 2019, 48(7): 97-104. (in Chinese). doi:
  19. 19.
    ZHU X B, CHEN J, DENG SH X, et al. Aberrations in complex spectral instruments[J]. Acta Optica Sinica, 2006, 26(1): 116-120. (in Chinese)
  20. 20.
    TAN Y. The simulation study of Fraunhofer diffraction pattern by twin rectangle aperture[J]. Metrology & Measurement Technique, 2018, 45(7): 10-12. (in Chinese)
  21. 21.
    NGUYEN N H. U-Net based skeletonization and bag of tricks[C]. 2021 IEEE/CVF International Conference on Computer Vision Workshops (ICCVW).11-17,2021, Montreal, BC, Canada. IEEE, 2021: 2105-2109. doi:

قراءة النص الكامل

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website