CO2-Hohlraumspektrometer mit Nachweisempfindlichkeit im ppb-Bereich

  • role: First author第一作者
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    University of Science and Technology of China, Hefei 230026, China

  • Email:yliu@aiofm.ac.cn
  • Introduction:刘 英(1998-),女,四川宜宾人,博士研究生,2018年于安徽大学获得学士学位,主要从事激光吸收光谱方面的研究。E-mail: yliu@aiofm.ac.cn
LIU Ying12,  
  • Affiliation:

    Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong 999077, China

HU Mai3,  
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

WANG Xingping1,  
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

XU Zhenyu1,  
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

HE Yabai1,  
  • role: Corresponding author通信作者
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

  • Email:kanruifeng@aiofm.ac.cn
  • Introduction:阚瑞峰(1977-),男,辽宁锦州人,博士,研究员,2000年于长春理工大学获得学士学位;2003年、2006年于中国科学院安徽光机所分别获得硕士与博士学位,主要从事光学与光谱学方面的研究。E-mail:kanruifeng@aiofm.ac.cn
KAN Ruifeng1*

Resümee

Kohlenstoffdioxid (Carbon dioxide, CO2) ist das wichtigste Treibhausgas in der Atmosphäre und zeichnet sich durch eine hohe atmosphärische Grundkonzentration und eine geringe jährliche Schwankung aus. Daher ist die hochpräzise Überwachung seiner Konzentration ein wichtiger Schritt zur Erreichung des "Kohlenstoffdoppelziels". Dieser Artikel basiert auf der Technologie der kontinuierlichen Wellen-Hohlraumspektroskopie und hat eine CO2-Gassensorvorrichtung mit einer Empfindlichkeit im ppb-Bereich aufgebaut. Im System wurde die Absorptionslinie des CO2 mit einer zentralen Wellenzahl von 6251,760 cm-1 ausgewählt, ein Quarzglas-Fabry-Pérot-Resonator mit ultrahoher Feinheit (>300.000) entworfen sowie ein hochleistungsfähiges Temperatur- und Druckregelungsmodul eingesetzt. Die Änderungen der Temperatur und des Drucks des Gases im Resonator lagen innerhalb von 24 Stunden unter 0,07 ℃ bzw. 15 Pa. Die Allan-Varianz-Ergebnisse zeigen, dass das System bei einer optimalen Integrationszeit von 303 s eine Nachweisgrenze von 0,7×10-12 cm-1 erreicht, was einer minimal detektierbaren CO2-Konzentration von 1,6 ppb entspricht. Im größeren CO2-Konzentrationsbereich beträgt der lineare Korrelationskoeffizient der Systemantwort 0,99994. Schließlich führte das System mit einer Ansprechzeit von 10 s über 2 Tage eine kontinuierliche Beobachtung der CO2-Konzentration in der Atmosphäre durch; die Ergebnisse stimmten hochgradig mit den Überwachungsdaten eines kommerziellen Instruments (Picarro, G2401) überein, wobei die relative Abweichung nach Ausschluss der menschlichen Atemstörung unter 6‰ lag. Das System zeichnet sich durch eine einfache Struktur, geringe Kosten und eine extrem hohe Empfindlichkeit aus und bietet weitreichende Anwendungsperspektiven im Bereich der Spurengasüberwachung.

Schlüsselwort

CO2-Detektion;Optischer Sensor;Hohlraumspektroskopie;Extrem hohe Empfindlichkeit

References

  1. 1.
    BOUCHER O, BORELLA A, GASSER T, et al. On the contribution of global aviation to the CO2 radiative forcing of climate[J]. Atmospheric Environment, 2021, 267: 118762. doi:
  2. 2.
    LIU W, WEI N N, WANG G H, et al. Quantitative estimation source of urban atmospheric CO2 by carbon isotope composition[J]. Chinese Journal of Environmental Science, 2012, 33(4): 1041-1049.(in Chinese). doi:
  3. 3.
    YUAN F, GAO J, YAO L, et al. Development of highly sensitive balloon-borne methane measurement system based on cavity ringdown spectroscopy[J]. Opt. Precision Eng., 2020, 28(9): 1881-1892.(in Chinese). doi:
  4. 4.
    AI Y K, LI J, LI Q Y, et al. Cavity ringdown spectroscopy of nitric oxide in the ultraviolet region for human breath test[J]. Journal of Breath Research, 2020, 14(3): 037101. doi:
  5. 5.
    MONDAL K, KAIPARA R, RAJAKUMAR B. Investigation of the absorption cross section of phenyl radical and its kinetics with methanol in the gas phase using cavity ring-down spectroscopy and theoretical methodologies[J]. The Journal of Physical Chemistry A, 2019, 123(45): 9682-9692. doi:
  6. 6.
    WANG J N, ZHENG L J, NIU X T, et al. Design and fabrication of a mid-infrared carbon dioxide sensor for the application in greenhouse environment[J]. Optoelectronics Letters, 2016, 12(5): 379-383. doi:
  7. 7.
    ESLER M B, GRIFFITH D W T, WILSON S R, et al. Precision trace gas analysis by FT-IR spectroscopy. 1. simultaneous analysis of CO2, CH4, N2O, and CO in air[J]. Analytical Chemistry, 2000, 72(1): 206-215. doi:
  8. 8.
    LI M X, CHEN B, RUAN J, et al. On-line detection of carbon dioxide in large scale offshore by laser technology[J]. Opt. Precision Eng., 2020, 28(7): 1424-1432.(in Chinese). doi:
  9. 9.
    FUNKE H H, GRISSOM B L, MCGREW C E, et al. Techniques for the measurement of trace moisture in high-purity electronic specialty gases[J]. Review of Scientific Instruments, 2003, 74(9): 3909-3933. doi:
  10. 10.
    ROMANINI D, KACHANOV A A, SADEGHI N, et al. CW cavity ring down spectroscopy[J]. Chemical Physics Letters, 1997, 264(3/4): 316-322. doi:
  11. 11.
    PALDUS B A, JrHARRIS J S, MARTIN J, et al. Laser diode cavity ring-down spectroscopy using acousto-optic modulator stabilization[J]. Journal of Applied Physics, 1997, 82(7): 3199-3204. doi:
  12. 12.
    HAHN J W, YOO Y S, LEE J Y, et al. Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design[J]. Applied Optics, 1999, 38(9): 1859-1866. doi:
  13. 13.
    ORR BJ, HE Y. Rapidly swept continuous-wave cavity-ringdown spectroscopy[J]. Chemical Physics Letters, 2011, 512(1/2/3): 1-20. doi:
  14. 14.
    CHEN B, SUN Y R, ZHOU Z Y, et al. Ultrasensitive, self-calibrated cavity ring-down spectrometer for quantitative trace gas analysis[J]. Applied Optics, 2014, 53(32): 7716. doi:
  15. 15.
    CROSSON E R. A cavity ring-down analyzer for measuring atmospheric levels of methane, carbon dioxide, and water vapor[J]. Applied Physics B, 2008, 92(3): 403-408. doi:
  16. 16.
    WANG J D, YU J, MO Z Q, et al. Multicomponent gas detection based on concise CW-cavity ring-down spectroscopy with a bow-Tie design[J]. Applied Optics, 2019, 58(11): 2773. doi:
  17. 17.
    SONG S M. Continuous Wave Cavity Ring-Down Spectroscopy Device and Trace Methane Detection[D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2019. (in Chinese)
  18. 18.
    GUO R M, TENG J H, CAO K, et al. Comb-assisted, Pound-Drever-Hall locked cavity ring-down spectrometer for high-performance retrieval of transition parameters[J]. Optics Express, 2019, 27(22): 31850. doi:
  19. 19.
    MA G S, LIU Y, DENG H, et al. High finesse optical feedback cavity ringdown spectroscopy[J]. Opt. Precision Eng., 2022, 30(19): 2305-2312. (in Chinese). doi:
  20. 20.
    BURKART J, ROMANINI D, KASSI S. Optical feedback frequency stabilized cavity ring-down spectroscopy[J]. Optics Letters, 2014, 39(16): 4695. doi:
  21. 21.
    HU M, CHEN X, ZHANG H, et al. Fast optical cavity ring-down spectroscopy detection based on first harmonic frequency locking[J]. Opt. Precision Eng., 2022, 30(4): 363-371. (in Chinese). doi: