Design and testing of thin-film temperature sensors integrated on harmonic reducer

  • role: First author第一作者
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

  • Email:csx2000820@163.com
  • Introduction:曹嘉鋆(2000-),女,江苏泰州人,硕士研究生,2022年于西安理工大学获得学士学位,主要从事机器人关节温度测量方面的研究。 E-mail: csx2000820@163.com
CAO Jiajun,  
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

SHEN Wenqiang,  
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

WANG Xiaodong,  
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

YANG Jinyi,  
  • role: Corresponding author通信作者
  • Affiliation:

    School of Mechanical Engineering, Dalian University of Technology, Dalian 116023, China

  • Email:louzf@dlut.edu.cn
  • Introduction:娄志峰(1978-),男,黑龙江肇东人,副教授,1999年、2008年于大连理工大学分别获得学士和博士学位,研究方向为微小组件自动装配技术、数控机床误差测量与补偿技术等。E-mail: louzf@dlut.edu.cn
LOU Zhifeng*

Resümee

Die Erfassung von Temperaturdaten in Echtzeit während des Betriebs des Harmonic Reducer und deren Überwachung trägt dazu bei, Fehler schnell zu diagnostizieren und die Leistung zu verbessern. Daher wurde ein dünner Temperatursensor, der im Inneren des Harmonic Reducer integriert ist, vorgeschlagen. Um den Einfluss der Verformung des flexiblen Rades auf die Genauigkeit der Temperaturmessung des Sensors während des Betriebs des Harmonic Reducer zu reduzieren, wurde eine Finite-Elemente-Analyse der verschiedenen Betriebszustände des Harmonic Reducer durchgeführt und ein Konstruktionsentwurf des dünnen Temperatursensors entwickelt, um den Einfluss der Verformung auf die Temperaturmessung zu verringern. Ein dünner Temperatursensor wurde unter Verwendung der MEMS-Technologie hergestellt, der Einfluss der Verformung auf die Temperatur wurde kompensiert und die Messleistung des Temperatursensors wurde getestet. Die Testergebnisse zeigten, dass die statische Temperaturmessgenauigkeit für den dünnen Temperatursensor ± 0,30% beträgt und die dynamische Temperaturmessgenauigkeit ± 0,52% beträgt. Wiederholte Experimente zur Messleistung des lokal hergestellten dünnen Temperatursensors zeigten, dass die Standardabweichung im Temperaturbereich von 20 bis 120 °C im Vergleich zum Standard-Temperatursensor 0,072 bis 0,296 °C beträgt, was die Erfassung des Betriebstemperatursignals des Harmonic Reducer in Echtzeit ermöglicht.

Schlüsselwort

temperature sensor;harmonic reducer;finite element analysis;integrated sensor

References

  1. 1.
    ZHANG Q, NIU L ZH, FAN Y N, et al. Design of robot joint torque measurement sensor[J]. Chinese Journal of Sensors and Actuators, 2020, 33(4): 506-510. (in Chinese). doi:
  2. 2.
    PERRONE M, MELL S P, MARTIN J, et al. Machine learning-based prediction of hip joint moment in healthy subjects, patients and post-operative subjects[J]. Computer Methods in Biomechanics and Biomedical Engineering, 2025, 28(7): 1093-1097. doi:
  3. 3.
    LI X H, LIU J K, WANG SH. Transmission performance test of harmonic gear lubricated with 601EF grease under vacuum thermal cycling environment[J]. Spacecraft Environment Engineering, 2011, 28(5): 450-453. (in Chinese)
  4. 4.
    WANG Y H, LIU J H, GUAN E G, et al. Analysis of fatigue failure characteristics of harmonic reducer[J]. Machine Tool & Hydraulics, 2021, 49(23): 159-164. (in Chinese)
  5. 5.
    QU B, LI ZH, GUO X, et al. Accuracy of the strain gauge torque sensor influenced by temperature and the measured value correction[J]. Electrical Machinery Technology, 2020(5): 59-61. (in Chinese)
  6. 6.
    ZHAO Y Y, LI P X, DING H L, et al. Harmonic reducer performance prediction algorithm based on multivariate state estimation and LargeVis dimensionality reduction[J]. IEEE Access, 2023, 11: 126762-126774. doi:
  7. 7.
    PEREZ-DIAZ J, DIEZ-JIMENEZ E, VALIENTE-BLANCO I, et al. Performance of magnetic-superconductor non-contact harmonic drive for cryogenic space applications[J]. Machines, 2015, 3(3): 138-156. doi:
  8. 8.
    VASSILEVA D, KIYOSAWA Y, SUZUKI M. Sensorless torque control for a robot with harmonic drive reducers[J]. Mechanics Based Design of Structures and Machines, 2011, 39(2): 253-267. doi:
  9. 9.
    SHI Y, YIN H CH, LI J Y, et al. Modeling and parameter identification of friction characteristics of harmonic reducer[J]. Journal of Northeastern University (Natural Science), 2022, 43(1): 89-96, 110. (in Chinese)
  10. 10.
    XU D, ZHANG L,LUO ZH L. A device for temperature detection of flexible gears in harmonic reducers: CN112432710A [P]. 2021-03-02. (in Chinese).
  11. 11.
    DOLBIER W R, BEACH W F. Parylene-AF4: a polymer with exceptional dielectric and thermal properties[J]. Journal of Fluorine Chemistry, 2003, 122(1): 97-104. doi:
  12. 12.
    YAN W P, LI H N, LIU J S, et al. EPMA and XRD study on nickel metal thin film for temperature sensor[J]. Sensors and Actuators A: Physical, 2007, 136(1): 212-215. doi:
  13. 13.
    XU J, SHAO T M, JIN G. Effect of processing conditions on microstructure and electrical characteristics of Ni thin films[J]. Vacuum, 2009, 84(4): 478-482. doi:
  14. 14.
    MA B H, REN J Z, DENG J J, et al. Flexible thermal sensor array on PI film substrate for underwater applications[C]. 2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS). January 24-28, 2010. Wanchai, Hong Kong, China. IEEE, 2010: 679-682.
  15. 15.
    PHATTHANAKUN R, DEEKLA P, PUMMARA W, et al. Design and fabrication of thin-film aluminum microheater and nickel temperature sensor[C]. 2012 7th IEEE International Conference on Nano/Micro Engineered and Molecular Systems (NEMS). March 5-8, 2012. Kyoto, Japan. IEEE, 2012: 112-115.
  16. 16.
    TURKANI V S, NARAKATHU B B, MADDIPATLA D, et al. Nickel based printed resistance temperature detector on flexible polyimide substrate[C]. 2018 IEEE SENSORS. October 28-31, 2018. New Delhi. IEEE, 2018: 1-4. doi:
  17. 17.
    CUI J T, LIU H, LI X L, et al. Fabrication and characterization of nickel thin film as resistance temperature detector[J]. Vacuum, 2020, 176: 109288. doi:
  18. 18.
    RODGER D C, LI W, AMERI H, et al. Flexible parylene-based microelectrode technology for intraocular retinal prostheses[C]. 2006 1st IEEE International Conference on Nano/Micro Engineered and Molecular Systems. January 18-21, 2006. Zhuhai, China. IEEE, 2006: 743-746.
  19. 19.
    WANG X D, DU ZH J, SHEN W Q, et al. Design and testing of harmonic reducer integrated with torque sensor[J]. Optics and Precision Engineering, 2024, 32(19): 2899-2910. (in Chinese). doi:
  20. 20.
    GAO H L, SHEN W Q, DU ZH J, et al. Development of integrated torque sensor for harmonic reducer and Error Compensation[J]. Opt. Precision Eng., 2024, 32(12): 1857-1867. (in Chinese). doi:

Lesen Sie die ganze Passage