Laserverfolgtes Ausgleichungskantenmessnetzwerk mit mehreren Referenzbeschränkungen

  • role: First author第一作者
  • Affiliation:

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China

    University of Chinese Academy of Sciences, Beijing 100049, China

    State Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun 130033, China

  • Email:shaofuhai23@mails.ucas.ac.cn
  • Introduction:邵福海(2001-),女,新疆乌苏人,硕士研究生,2023年于武汉大学获得学士学位,主要从事精密测量方面的研究。E-mail: shaofuhai23@mails.ucas.ac.cn
SHAO Fuhai123,  
  • role: Corresponding author通信作者
  • Affiliation:

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China

    University of Chinese Academy of Sciences, Beijing 100049, China

    State Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun 130033, China

  • Email:zxf@ciomp.ac.cn
  • Introduction:曾雪锋(1987-),男,江西抚州人,博士,研究员,2009年于南京理工大学获得学士学位,2014年于中国科学院长春光学精密机械与物理研究所获得博士学位,主要从事先进光学制造技术方面的研究。E-mail:zxf@ciomp.ac.cn
ZENG Xuefeng123*,  
  • Affiliation:

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China

    State Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun 130033, China

LI Wenyan13,  
  • Affiliation:

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China

    University of Chinese Academy of Sciences, Beijing 100049, China

    State Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun 130033, China

WANG Lingjie123,  
  • Affiliation:

    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China

    University of Chinese Academy of Sciences, Beijing 100049, China

    State Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun 130033, China

ZHANG Xuejun123

Resümee

Die Ausgleichungsmethode für Laserverfolgungs-Kantenmessnetzwerke weist erhebliche Vorteile bei der hochpräzisen Positionsbestimmung im dreidimensionalen Raum auf, wobei die genaue Kalibrierung der Systemparameter der Schlüssel zur Erreichung hochpräziser Messungen ist. Zur Bewältigung der Probleme der Instabilität der geometrischen Referenz und der Empfindlichkeit der Ausgleichungsergebnisse gegenüber Anfangswerten im traditionellen Selbstkalibrierungsprozess des Kantenmessnetzwerks wird eine optimierte Ausgleichungsmethode vorgeschlagen. Diese Methode führt ein Orientierungspunktmodell ein, das mehrere Raumreferenzen bereitstellt, um die Koordinaten der Messstationen selbst zu kalibrieren und während des Netzwerk-Ausgleichsprozesses die Koordinaten der Orientierungspunkte zu fixieren, um eine gemeinsame optimale Lösung der Messstationskoordinaten unter einer einheitlichen geometrischen Referenz zu erreichen. Simulationsergebnisse zeigen, dass unter Bedingungen mit gaußschem Rauschen in Entfernungs- und Punktmessungen die Methode eine gute Stabilität der Berechnung aufweist und der Fehler in den Kantenlängen im Mikrometerbereich liegt. Durch Messungen mit einer Ein-Meter-Standardstange wurde die Methode mit den Ergebnissen der kommerziellen Software Spatial Analyzer (SA) verglichen, wobei sich herausstellte, dass im Messbereich von 1,5 m × 1,5 m der optimierte Messfehler der räumlichen Länge zwischen -0,3 und 4,8 μm liegt, während die Fehler von SA hauptsächlich im Bereich von 3,0 bis 9,5 μm liegen. Die Methode bietet eine bessere Messleistung hinsichtlich Genauigkeit und Streuung und verfügt über gute Generalisierbarkeit, was technische Unterstützung für Raumvermessungsaufgaben wie die Justage optischer Systeme bietet.

Schlüsselwort

Lage- und Ortsbestimmung; Ausgleichung des Kantenmessnetzwerks; geometrische Beschränkungen; auf Netzwerkausgleich basierendes Selbstkalibrierungsmodell

References

  1. 1.
    YU Y, WANG X W, XU ZH B, et al. Parallel adjustment mechanism for large aperture telescope based on flexible hinges[J]. Optics and Precision Engineering, 2023, 31(3): 352-362. (in Chinese). doi:
  2. 2.
    LI W X, SHEN J L, ZHANG X X, et al. Design of low temperature infrared off-axis three-mirror collimation system[J]. Optics and Precision Engineering, 2023, 31(9): 1285-1294. (in Chinese). doi:
  3. 3.
    YUE L Q, LI B, LI CH Y, et al. Research on the vertical installation and adjustment of large-aperture space optical remote sensing camera[J]. Infrared and Laser Engineering, 2025, 54(3): 156-163. (in Chinese)
  4. 4.
    ZHANG X M, SONG X, HOU X H, et al. Alignment of focus-adjustable off-axis reflective optical system[J]. Optics and Precision Engineering, 2017, 25(6): 1458-1463. (in Chinese). doi:
  5. 5.
    ZHANG Q Y, LI J SH, MIAO D J. A review of laser multilateration coordinate measurement systems and their development status[J]. Metrology Science and Technology, 2024, 68(9): 32-40, 60. (in Chinese). doi:
  6. 6.
    RAFELD E K, KOPPERT N, FRANKE M, et al. Recent developments on an interferometric multilateration measurement system for large volume coordinate metrology[J]. Measurement Science and Technology, 2022, 33(3): 035004. doi:
  7. 7.
    GAO D D, DONG D F, QIU Q F, et al. Large range automatic attitude measurement method for laser tracking measurement[J]. Optics and Precision Engineering, 2024, 32(7): 976-986. (in Chinese). doi:
  8. 8.
    WU B, XU Y, YANG F T, et al. 3D coordinate measuring system based on laser tracking absolute length measurement multilateral method[J]. Infrared and Laser Engineering, 2018, 47(8): 130-135. (in Chinese). doi:
  9. 9.
    XU Y M, ZHENG Q, GUAN X. Precision analysis of leica AT960 absolute laser tracker[J]. Journal of Geomatics, 2020, 45(1): 8-12. (in Chinese). doi:
  10. 10.
    SHENG Y, WANG Y K, LIU S W, et al. Large-scale measurement layout optimization method based on laser multilateration[J]. Machines, 2022, 10(11): 988. doi:
  11. 11.
    FAN B X, LI G Y, LI P ZH, et al. Adjustment of a laser interferometer 3D rank-defect free-network[J]. Geomatics and Information Science of Wuhan University, 2015, 40(2): 222-226, 232. (in Chinese). doi:
  12. 12.
    LIU SH, LIU G B, LIU SH G. Adjustment of 3-D laser tracking network based on barycenter datum[J]. Journal of Shandong University of Science and Technology (Natural Science), 2021, 40(6): 20-27. (in Chinese). doi:
  13. 13.
    ZHENG J H, MIAO D J, LI J SH, et al. Self-calibration algorithm for laser multilateral coordinate measurement system using standard length method[J]. Acta Metrologica Sinica, 2019, 40(1): 64-70. (in Chinese)
  14. 14.
    WANG ZH Y, HE X Y, WANG W, et al. High precision pre-alignment method based on laser tracker[J]. Geomatics and Information Science of Wuhan University, 2021, 46(4): 555-560. (in Chinese). doi:
  15. 15.
    WANG T, ZHOU W H, DONG L, et al. Accuracy of control network measured by laser tracker in particle accelerator[J]. Geomatics and Information Science of Wuhan University, 2024, 49(1): 156-166. (in Chinese). doi:
  16. 16.
    MANWILLER P E. Three-dimensional network adjustment of laser tracker measurements for large-scale metrology applications[J]. Journal of Surveying Engineering, 2021, 147: 05020009. doi:
  17. 17.
    VIKAS, SAHU R K. A review on application of laser tracker in precision positioning metrology of particle accelerators[J]. Precision Engineering, 2021, 71: 232-249. doi:

Lesen Sie die ganze Passage

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website