Measurement for cutoff depth of out-band of solar blind UV filters
A measuring system for the cutoff depth of out-band of solar blind UV filters with a large dynamic range is proposed by using narrow-band Light Emitting diode(LED) lights as the standard light source. The measuring error of the system is also analyzed. The system consists of LED light sources
the standard reflective neutral attenuators known attenuation coefficients and a photomultiplier. Based on substitution method
the photomultiplier detects the current of the LED through the attenuator as reference to substitute LED initial current
thus the cutoff depth of the out-band of filters is acquired. For the reflective attenuator in the system
an attenuator combination method is presented to insure the photomultiplier working continuously within a linear response range. Experimental results show that the cutoff depth of the out-band of filters is measured to 11-OD in the large spectral range of 350-800 nm. Furthermore
the uncertainty is less than 2% and the relative repeatability error is less than 0.2%. The measuring system has a simpler structure
higher precise
a large spectral range and a wider dynamic range and has been widely used in the measurement of the filter cutoff depth of filters.
关键词
Keywords
references
王保华,李妥妥,郑国宪. 日盲紫外探测系统研究[J]. 激光与光电子学进展,2014,51:022202. WANG B H, LI T T, ZHENG G X. Research of solar blind ultraviolet detection system [J]. Laser & Optoelectronics Progress, 2014,51:022202. (in Chinese)
戴利波. 紫外成像技术在高压设备带电检测中的应用[J]. 电力系统自动化,2003,27(20):97-98. DAI L B. The application of UV imagery technology in the high-tension apparatus detection [J]. Autormation of Electric Power Systems, 2003,27(20):97-98.(in Chinese)
王丽萍,李春, 金春水. “日盲”紫外折反射全景光学系统设计[J]. 光学 精密工程,2011,19(7): 1503-1509. WANG L P, LI CH, JIN CH SH. Design of catadioptric omnidirectional imaging system in solar blind UV [J].Opt. Precision Eng., 2011,19(7): 1503-1509.(in Chinese)
周伟,马妮,吴晗平. 近地层紫外探测作用距离及其影响因素研究[J]. 红外技术,2011,33(6): 357-371. ZHOU W, MA N, WU H P. Operating rang of ultraviolet detection system in the surface layer and the study of its influence factors[J]. Infrared Technology,2011,33(6): 357-371.(in Chinese)
刘晓科,马君,唐辉,等. 一种日盲区紫外信号探测系统前端[J]. 探测与控制学报,2007,29(6):41-44. LIU X K, MA J, TANG H, et al.. A front-end of ultraviolet signal detection system based on solar-blind region [J]. Journal of Detection & Control, 2007,29(6):41-44.(in Chinese)
吴礼刚,何文荣,胡晋荪,等. 日盲紫外-可见光双光谱照相机系统[J]. 光学 精密工程,2010,18(7):1529-1534. WU L G, HE W R, HU J S,et al.. Solar blind UV and visible dual-spectral camera [J]. Opt. Precision Eng.,2010,18(7):1529-1534.(in Chinese)
陈健, 王伟国, 高慧斌, 等. 紫外探测器的辐射定标及标准传递[J]. 中国光学, 2012, 5(4): 423-429. CHEN J, WANG W G, GAO H B,et al..Radiation calibration for UV detectors and standard transferring [J]. Chinese Optics, 2012, 5(4): 423-429.(in Chinese)
王正凤,付秀华,张静,等. 日盲紫外告警系统中成像滤光片的研制[J]. 中国激光,2011,38(12):1207002. WANG ZH F, FU X H, ZHANG J,et al..Research of imaging filter in solar blind ultraviolet alarm system [J].Chinese Journal of Lasers,2011,38(12): 1207002.(in Chinese)
LAIHO K, CHRIST A, CASSEMIRO K N,et al..Testing spectral filters as Gaussian quantum optical channels [J]. Optics Letters, 2011, 36(8): 1476-1478.
DAVID A, COMPTON C, JOHN D,et al..Accurate infrared transmittance measurements on optical filters using an FT-IR spectrometer [J]. Applied Optics,1990, 29(19): 2908-2912.
曲艺. 真空紫外波段光栅二级衍射效率测量装置[J]. 中国光学, 2010,3(6): 566-571. QU Y. Measuring instrument for second-order diffraction efficiency of grating in vacuum ultraviolet [J]. Chinese Journal of Optics, 2010,3(6): 566-571.(in Chinese)
王锐,王淑荣,郭劲,等. 高精度紫外标准探测器的定标[J]. 光学 精密工程,2012, 20(8): 1696-1703. WANG R, WANG SH R, GUO J,et al.. Calibration of high accuracy UV standard detector [J].Opt. Precision Eng.,2012, 20(8): 1696-1703.(in Chinese)
汪舰,魏建平,杨波,等. 高透明液体透射率的测定[J]. 光学 精密工程,2013, 21(3): 624-629. WANG J, WEI J P, YANG B, et al.. Measurement of transmittance for highly transparent liquid [J]. Opt. Precision Eng.,2013, 21(3): 624-629.(in Chinese)
陈栋,黄云,张斌,等. 透反射率自动化测量系统设计[J]. 光学技术, 2007, 33:210-213. CHEN D, HUANG Y, ZHANG B, et al..Design of transmissivity and reflectivity automatic measuring system [J]. Optical Technique, 2007,33:210-213.(in Chinese)
刘卫国,孙鑫,高爱华,等. 线性渐变滤光片透过率实时测量系统[J]. 西安工业大学学报,2009,29(6): 515-518. LIU W G, SUN X, GAO A H,et al. The development of a real-time transmittance measuring system for linear variable neutral density filters [J]. Journal of Xi'an Technological University, 2009,29(6): 515-518.(in Chinese)
Design of infrared temperature measurement system for micro heat pipe
Illumination uniformity of an imaging system for on-line visual ferrograph
Spectrum-tunable light source based on multi-sources
LED-based projection light source for solid-state volumetric true-3D display
Photoelectric parameter measurement system based on Cortex-M3 for LEDs
Related Author
Cong-ming LI
Yi LUO
Chuan-peng ZHOU
Xiao-dong WANG
Song FENG
Jun-hong MAO
Bo LI
LIU Hong-xing
Related Institution
Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology
Key Laboratory for Precision and Non-traditional Machining of the Ministry of Education, Dalian University of Technology
Theory of Lubrication & Bearing Institute, Key Laboratory of Education Ministry for Modern Design and Rotor-Bearing Systems, Xi'an Jiaotong University
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
Key Laboratory of Special Display Technology of the Ministry of Education, National Engineering Laboratory of Special Display Technology, National Key Laboratory of Advanced Display Technology, Academy of Photoelectric Technology, Hefei University of Technology