SUN Shi-zheng, CHEN Xi-hou, PENG Dong-lin etc. Dynamic self-calibration for embedded time grating sensors[J]. Editorial Office of Optics and Precision Engineering, 2014,22(10): 2757-2764
SUN Shi-zheng, CHEN Xi-hou, PENG Dong-lin etc. Dynamic self-calibration for embedded time grating sensors[J]. Editorial Office of Optics and Precision Engineering, 2014,22(10): 2757-2764 DOI: 10.3788/OPE.20142210.2757.
Dynamic self-calibration for embedded time grating sensors
A dynamic self-calibration method was proposed for an embedded time grating sensor to improve its measuring accuracy when it worked at changed electric parameters and measuring environments and could not be calibrated by a standard instrument. The features of the embedded time grating sensor were introduced
and a self-calibration method was presented by using error regular transformation of two discrete probes in a certain angle. Then
a dynamic self-calibration system was designed. To reduce the influence of sensor stability and environmental disturbance on the dynamaic calibrating processing
a Kalman filter was used. Moreover
an algorithm for residual control was proposed to ensure calibration precision. Finally
the self-calibration system was applied to calibration of the embedded time grating sensor.This calibration method was compared with the traditional standard method. Experiment results show that the original errors of sensor have been reduced from ±20" to ±2.4"
which is nearly the same as the accuracy of standard instrument calibration and has been satisfied the calibration requirements of time grating sensors.
关键词
Keywords
references
彭东林,刘小康,张兴红,等. 高精度时栅位移传感器研究[J]. 机械工程学报,2005,41(12):126-129. PENG D L, LIU X K, ZHANG X H, et al.. Research on high-precision time-grating displacement sensor[J]. Journal of Mechnacial Engineering, 2005,41(12):126-129. (in Chinese)
彭东林,刘小康,张兴红,等. 基于谐波修正法的高精度时栅位移传感器[J]. 仪器仪表学报,2006,27(1):31-33. PENG D L, LIU X K, ZHANG X H, et al.. High-precision time-grating displacement sensor based on harmonic wave correcting method[J]. Chinese Journal of Scientific Instrument, 2006, 27(1):31-33. (in Chinese)
彭东林,李彦,付敏,等. 用于极端和特殊条件下机械传动误差检测的寄生式时栅研究[J]. 仪器仪表学报,2013,34(2):359-364. PENG D L, LIU Y, FU M, et al.. Study on parasitic time grating sensors used for mechanical transmission error measurement under harsh and special environment[J]. Chinese Journal of Scientific Instrument, 2013, 34(2):359-364. (in Chinese)
高策,乔彦峰. 光电经纬仪测量误差的实时修正[J]. 光学 精密工程,2007,15(6):846-851. GAO C,QIAO Y F. Real-time error-correction method for photoelectrical theodolitet[J]. Opt. Precision Eng., 2007, 15(6):846-851. (in Chinese)
MASUD A, KAJITANI P. An automatic calibration system for angular encoders[J]. Precision Engineering, 1989, 11(2):95-100.
WATANABE T, FUJIMOTO H. NAKAYAMA K, et al.. Automatic high precision calibration system for angular encoder[J]. SPIE, 2003,51(4):400-409.
WATANABE T, FUJIMOTO H. Self-calibration rotary encoder[C]. Proceedings of the Fifth International Conference on Electrical Machines and Systems, Shenyang, P.R. China: ICEMS, 2005:240-245.
X.D L, TRUMPER D L. Self-calibration of on-axis rotary encoders[J]. Annals of the CIRP, 2007, 56(1):499-504.
AMIN S D.On-axis self-calibration of angle encoders [J].CIRP Annals Manufacturing Technology, 2010,59(1):529-534.
杨伟,彭东林,朱革. 基于变藕合系数变压器原理的时栅位移传感器设计[J]. 仪器仪表学报,2006,27(11):1403-1405. YANG W, PENG D L, ZHU G. Design of time grating sensor based on variable coupling coefficient transformer[J]. Chinese Journal of Scientific Instrument, 2006, 27(11):1403-1405. (in Chinese)
郭立红,朱玮,李岩,等. 基于卡尔曼滤波技术解算惯导的水平偏差[J]. 光学 精密工程,2003,11(4):379-384. GUO L H, ZHU W, LI Y,et al.. Using Kalmen filter technology establishment of attitude and course errors for measurement ship inertial navigation system [J]. Opt. Precision Eng., 2003, 11(4):379-384. (in Chinese)
王晓初,尤政,赵开春. 基于改进的无迹卡尔曼滤波确定视线感知相对状态[J]. 光学 精密工程,2013,21(4):1032-1039. WANG X CH, YOU ZH, ZHAO K CH,et al.. Determination of vision-based relative state by modified unscented Kalman filter [J]. Opt. Precision Eng., 2013, 21(4): 1032-1039. (in Chinese)