References
- 1.DAVIS N M, FRANCIS D, HODGKINSON J, et al. Compact methane sensor using an integrating sphere and interband cascade laser at 3313 nm[J]. Sensors and Actuators B: Chemical, 2023, 389: 133866. doi:
- 2.LIU Y, SHANG Q, CHEN L, et al. Application of portable CH4 detector based on TDLAS technology in natural gas purification plant[J]. Atmosphere, 2023, 14(12):13. doi:
- 3.NIE W, XU Z Y, KAN R F, et al. Measurement of low water vapor dew-point temperature based on tunable diode laser absorption spectroscopy[J]. Opt. Precision Eng., 2018, 26(8): 1862. (in Chinese). doi:
- 4.LIU J Y, PAN Y, YAO L, et al. Mid-infrared laser absorption spectroscopy CO2 spectrometer[J]. Opt. Precision Eng., 2024, 32(9): 1330-1337. (in Chinese). doi:
- 5.WHITE J U. Long optical paths of large aperture[J]. Journal of the Optical Society of America (1917-1983), 1942, 32(5): 285. doi:
- 6.SHAO L G, CHEN J J, WANG K Y, et al. Highly precise measurement of atmospheric N2O and CO using improved White cell and RF current perturbation[J]. Sensors and Actuators B: Chemical, 2022, 352: 130995. doi:
- 7.LI Z, ZHANG Q R, WANG Z T, et al. A highly sensitive low-pressure TDLAS sensor for detecting dissolved CO and CO2 in transformer insulating oil[J]. Optics & Laser Technology, 2024, 174: 110622. doi:
- 8.CHERNIN S M, BARSKAYA E G. Optical multipass matrix systems[J]. Applied Optics, 1991, 30(1): 51-58. doi:
- 9.ZHANG Q L, XU X Z, ZHAO W X, et al. Measurement of aerosol optical properties using a chernin multipass cell[J]. Acta Optica Sinica, 2015, 35(9): 930001. (in Chinese). doi:
- 10.CHEN Y G, SHE X Y, LIU X, et al. Study on carbon monoxide and carbon dioxide measurement system based on chernin optical multipass cell[J]. Modern Information Technology, 2019, 3(9): 8-10, 13. (in Chinese)
- 11.BARRY MCMANUS J. Paraxial matrix description of astigmatic and cylindrical mirror resonators with twisted axes for laser spectroscopy[J]. Applied Optics, 2007, 46(4): 472-482. doi:
- 12.CHEN J J, WANG G S, LIU K, et al. High sensitivity detection of carbon dioxide based on portable cylindrical multi-pass cell[J]. Spectroscopy and Spectral Analysis, 2019, 39(1): 292. (in Chinese)
- 13.HERRIOTT D, KOGELNIK H, KOMPFNER R. Off-axis paths in spherical mirror interferometers[J]. Applied Optics, 1964, 3(4): 523. doi:
- 14.SUN H Y, MA Y F, HE Y, et al. Highly sensitive acetylene detection based on a compact multi-pass gas cell and optimized wavelength modulation technique[J]. Infrared Physics & Technology, 2019, 102: 103012. doi:
- 15.LI G L, WU Y H, ZHANG Z C, et al. WMS based dual-range real-time trace sensor for ethane detection in exhaled breath[J]. Optics and Lasers in Engineering, 2022, 159: 107222. doi:
- 16.DONG M, ZHENG C T, YAO D, et al. Double-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)[J]. Optics Express, 2018, 26(9): 12081-12091. doi:
- 17.CUI R Y, DONG L, WU H P, et al. Calculation model of dense spot pattern multi-pass cells based on a spherical mirror aberration[J]. Optics Letters, 2019, 44(5): 1108-1111. doi:
- 18.WEBSTER C R, FLESCH G J, BRIGGS R M, et al. Herriott cell spot imaging increases the performance of tunable laser spectrometers[J]. Applied Optics, 2021, 60(7): 1958-1965. doi:
- 19.MCMANUS J B, KEBABIAN P L, ZAHNISER M S. Astigmatic mirror multipass absorption cells for long-path-length spectroscopy[J]. Applied Optics, 1995, 34(18): 3336-3348. doi:
- 20.LI C L, GUO X Q, JI W H, et al. Etalon fringe removal of tunable diode laser multi-pass spectroscopy by wavelet transforms[J]. Optical and Quantum Electronics, 2018, 50(7): 275. doi:
- 21.ZHANG H, WANG L, ZOU C H, et al. Simulation of signal denoising methods in TDLAS system[J]. Laser Journal, 2022, 43(7): 31-38. (in Chinese). doi:
- 22.YAO X Y, ZHOU Q Z, WANG C, et al. An adaptive seismic signal denoising method based on variational mode decomposition[J]. Measurement, 2021, 177: 109277. doi:
- 23.ZHANG R L, TU X H. Variational mode decomposition and wavelet threshold function de-noising for second harmonics[J]. Acta Optica Sinica, 2022, 42(2): 0210001. (in Chinese). doi:
- 24.JIANG J. Research on Denoising of Laser Methane Detection Signal Based on Ssa-Vmd[D]. Hefei: Anhui Jianzhu University, 2024. (in Chinese)
- 25.TANG Q C, WANG Q, HONG Z M, et al. Research on TDLAS methane detection signal denoising based on improved VMD algorithms[J]. Journal of China University of Metrology, 2024, 35(1): 35-42. (in Chinese)
- 26.ZENG W Y, LIU X Y, MIAO Y X, et al. TDLAS second harmonic signal denoising research based on INGO-VMD-improved wavelet thresholding algorithm[J]. Laser Journal, 2024, 45(9): 53-61.(in Chinese)
- 27.SILVER J A. Simple dense-pattern optical multipass cells[J]. Applied Optics, 2005, 44(31): 6545-6556. doi:
- 28.SHEN C, ZHANG Y J, NI J Z. Compact cylindrical multipass cell for laser absorption spectroscopy[J]. Chinese Optics Letters, 2013, 11(9): 91201-91205. doi:
- 29.MCMANUS J B. Paraxial matrix description of astigmatic and cylindrical mirror resonators with twisted axes for laser spectroscopy[J]. Applied Optics, 2007, 46(4): 472-482. doi:
- 30.DRAGOMIRETSKIY K, ZOSSO D. Variational mode decomposition[J]. IEEE Transactions on Signal Processing, 2014, 62(3): 531-544. doi:
- 31.DEHGHANI M, HUBÁLOVSKÝ Š, TROJOVSKÝ P. Northern goshawk optimization: a new swarm-based algorithm for solving optimization problems[J]. IEEE Access, 2021, 9: 162059-162080. doi:
- 32.NIU R X. Research on Real-Time Temperature Monitoring Method based on Tunable Semiconductor Laser Absorption Spectrum[D]. Taiyuan: North University of China, 2022. (in Chinese)
- 33.SHI Y P, HU Z, NIU M S, et al. High-sensitive double incidence multi-pass cell for trace gas detection based on TDLAS[J]. Sensors and Actuators B: Chemical, 2024, 412: 135829. doi:


