Быстрый алгоритм удаления Smear с изображений CCD и его применение в наземной системе тестирования космических изображающих приборов

  • role: First author第一作者
  • Affiliation:

    Institutes of Physical Science and Information Technology, Anhui University, Hefei 230000, China

  • Email:1976312909@qq.com
  • Introduction:冯熠斌(2001-),男,江西抚州人,硕士研究生,2022年于江西农业大学获得学士学位,主要从事温室气体卫星CCD图像处理及其星载成像设备地面检测系统上的应用。E-mail:1976312909@qq.com
FENG Yibin1,  
  • role: Corresponding author通信作者
  • Affiliation:

    Institutes of Physical Science and Information Technology, Anhui University, Hefei 230000, China

  • Email:yuwang@ aiofm.ac.cn
  • Introduction:王 煜(1971-),男,北京人,博士,研究员,1993年于哈尔滨工业大学获得学士学位,2005年于英国斯特莱斯克莱德大学获得博士学位,中科院“百人计划”成员,主要从事航空、航天遥感设备的电子系统研发工作。E-mail: yuwang@ aiofm.ac.cn
WANG Yu1*,  
  • Affiliation:

    Institutes of Physical Science and Information Technology, Anhui University, Hefei 230000, China

LIU Guohua1,  
  • Affiliation:

    Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

LIN Fang2,  
  • Affiliation:

    Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

ZHANG Quan2,  
  • Affiliation:

    Institutes of Physical Science and Information Technology, Anhui University, Hefei 230000, China

HU Chengrui1,  
  • Affiliation:

    Institutes of Physical Science and Information Technology, Anhui University, Hefei 230000, China

ZHANG Xiaoli1

реферат

Космический гиперспектральный имager является важной нагрузкой атмосферных наблюдательных спутников и использует frame-transfer CCD для получения информации о распределении компонентов атмосферы Земли. Frame-transfer CCD обладает эффектом Smear, который влияет на точность спектральных измерений. Поскольку традиционный алгоритм удаления эффекта Smear на основе матричного описания двумерного изображения слишком сложен и не удовлетворяет требованиям системы наземного тестирования нагрузки по удалению эффекта Smear в реальном времени, на основе принципа работы frame-transfer CCD была использована алгебраическая форма для описания модели формирования Smear и выведен алгебраический алгоритм удаления Smear. Этот алгоритм избегает матричных вычислений традиционного матричного алгоритма удаления Smear, время выполнения которого составляет 1/500 от матричного алгоритма, что подходит для систем наземного тестирования с высокими требованиями к времени обработки, в основном для удаления эффекта на статических изображениях. Проанализированы причины возникновения Smear в frame-transfer CCD, на основе которых выведен алгебраический алгоритм удаления Smear, который по сравнению с матричным алгоритмом, реализованным с использованием библиотеки Eigen, улучшил время обработки с 8 с до 16 мс. Алгоритм применен в системе наземного тестирования космического гиперспектрального имager, обеспечивая функцию обработки изображений по удалению эффекта Smear в реальном времени.

ключеви́че слова́

Космический гиперспектральный имager;Frame-transfer CCD;Эффект Smear;Наземная система тестирования

References

  1. 1.
    NIMO Back Illuminated High Performance CCD Sensor [Z].Datasheet.
  2. 2.
    WANG Y, LU Y H, ZHOU H J, et al. Design and implementation of imaging circuit for satellite-borne high dynamic range differential optical absorption spectrometer[J]. Opt. Precision Eng., 2024, 32(13): 2017-2028. (in Chinese). doi:
  3. 3.
    LIN F, LIU W Q, WANG Y, et al. Automatic CCD full-well test system and its application in camera development[J]. Acta Photonica Sinica, 2023, 52(11): 199-210. (in Chinese). doi:
  4. 4.
    POWELL K, CHANA D, FISH D, et al. Restoration and frequency analysis of smeared CCD images[J]. Applied Optics, 1999, 38(8): 1343-1347. doi:
  5. 5.
    LI Y, LUO D G, SUN L, et al. Evaluation criteria and correction method of frame transfer CCD camera smearing[J]. Acta Photonica Sinica, 2022, 51(4): 143-157. (in Chinese). doi:
  6. 6.
    LIU L, LUO T D, LI B K, et al. Smear correction of asynchronous binning high frame rate CCD camera[J]. Opt. Precision Eng., 2017, 25(1): 217-223. (in Chinese). doi:
  7. 7.
    CHEN T Q, HU B L, LIU X B, et al. Fast smear correction method for CCD of hyperspectral imager on HJ-2A/B satellites[J]. Spacecraft Engineering, 2022, 31(3): 71-76. (in Chinese)
  8. 8.
    ZHANG Q. Study on Data Correction of Environmental Trace Gas Monitoring Instrument[D]. Hefei: University of Science and Technology of China, 2018. (in Chinese)
  9. 9.
    SUN J Q, ZHOU J, ZHU Y, et al. Smear removal of CCD camera in astronomic observation[J]. Opt. Precision Eng., 2011, 19(10): 2526-2532. (in Chinese). doi:
  10. 10.
    HAN Y, CHOI E, KANG M. Smear removal algorithm using the optical black region for CCD imaging sensors[J]. IEEE Transactions on Consumer Electronics, 2009, 55(4): 2287-2293. doi:
  11. 11.
    WANG Y, LU Y H, ZHAO X, et al. Design and implementation of CCD imaging circuit for satellite-borne DOAS spectrometer[J]. Laser & Infrared, 2015, 45(6): 663-668. (in Chinese). doi:
  12. 12.
    LI K W. Research on New Technologies of Optical CoherenceTomography System Software and Image Processing[D]. Chengdu: University of Electronic Science and Technology of China, 2024. (in Chinese). doi:
  13. 13.
    ZHU H. Research and Development of Hyperspectraldata Processing Software[D]. Xi'an: Xi'an Technological University, 2023. (in Chinese)
  14. 14.
    ZHANG H. Research and Software Development of Wire Rope Defect Rcognition Method Based on Image Processing[D]. Shenyang: Northeastern University, 2022. (in Chinese)

Читать полностью

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website