Проектирование системы мониторинга дыхания собак с гибридным TOF-датчиком

  • role: First author第一作者
  • Affiliation:

    College of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China

  • Email:1556887121@shu.edu.cn
  • Introduction:时正顺(2000-),男,江苏宿迁人,硕士研究生,2023年于浙江理工大学获得学士学位,现为上海大学机电工程与自动化学院机械专业硕士研究生,主要研究方向为智能传感系统开发,目前致力于非接触式宠物健康监测设备的系统研发。 E-mail:1556887121@shu.edu.cn
SHI Zhengshun1,  
  • role: Corresponding author通信作者
  • Affiliation:

    College of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China

  • Email:lhy320208@shu.edu.cn
  • Introduction:刘宏月(1983-),女,黑龙江人,副教授,现为上海大学机电工程与自动化学院教师,主要从事智能结构状态监测、智能传感系统研发等研究。 E-mail: lhy320208@shu.edu.cn
LIU Hongyue1*,  
  • Affiliation:

    Shanghai Lanshi Pet Hospital, Shanghai 200444, China

CAO Yan2

реферат

Для удовлетворения клинических потребностей в непрерывном мониторинге частоты дыхания при диагностике и лечении сердечной недостаточности у собак разработана новая бесконтактная система мониторинга дыхания с гибридным датчиком TOF (Time-of-Flight). Предложена гибридная архитектура датчика TOF «точка-сетка», построена адаптивная пространственная модель мониторинга для учета различных поз питомцев. Реализован совместный управляющий контроль временных последовательностей датчиков и предварительная обработка необработанных сигналов на базе встроенной платформы STM32, разработан алгоритм анализа дыхательных волн в реальном времени на верхнем уровне LabVIEW, а также проведена оптическая калибровка и оптимизация параметров измерения расстояния сетчатого TOF. Тестирование на мелких собаках в статичной обстановке показало ошибку измерения частоты дыхания системы ≤ 2 вдоха в минуту. Интерфейс LabVIEW может отображать дыхательную волну и значение BPM в режиме реального времени, что подтвердило применимость оптического TOF-датчика для мониторинга живых организмов. Гибридная система TOF «точка-сетка» за счет оптической оптимизации измерений и пространственной адаптации достигла высокой точности статичного мониторинга дыхания собак, предоставляя компактное и недорогое новое решение для биологического оптического измерения в ветеринарии.

ключеви́че слова́

Датчик TOF;Бесконтактный мониторинг;Частота дыхания питомцев;Собаки с сердечной недостаточностью;LabVIEW

References

  1. 1.
    LIU S. Pathogenic characteristics and preventive measures of canine viral enteritis[J]. Agriculture of Henan, 2025(5): 79-80. (in Chinese)
  2. 2.
    FAN M Y. Diagnosis of mitral insufficiency in an elderly dog[J]. Shandong Journal of Animal Science and Veterinary Medicine, 2024, 45(10): 57-59, 61. (in Chinese)
  3. 3.
    NADJA E SIGRIST DR MED VET D, ADAMIK DR MED VET K N, MARCUS G DOHERR DR MED VET P, et al. Evaluation of respiratory parameters at presentation as clinical indicators of the respiratory localization in dogs and cats with respiratory distress[J]. Journal of Veterinary Emergency and Critical Care, 2011, 21(1): 13-23. doi:
  4. 4.
    LI M W, KANG Y, KOU Y Q, et al. Exploratory study on quantitative analysis of nocturnal breathing patterns in patients with acute heart failure based on wearable devices[J]. Journal of Biomedical Engineering, 2023, 40(6): 1108-1116. (in Chinese)
  5. 5.
    SALT C, MORRIS P J, BUTTERWICK R F, et al. Comparison of growth patterns in healthy dogs and dogs in abnormal body condition using growth standards[J]. PLoS One, 2020, 15(9): e0238521. doi:
  6. 6.
    ZHANG Z Z, XIAO G L, SHI H Y, et al. Research developments in diagnostics and treatment of canine and feline heart diseases[J]. Modern Animal Husbandry Science & Technology, 2025(1): 104-107. (in Chinese)
  7. 7.
    REECEW O, ERICKSONH H, GOFFJ P, et al. Physiology of Domestic Animals[M]. USA: Wiley,2015.
  8. 8.
    XIAO L Y, WEN Y F, NONG S J, et al. Prevention and control measures of canine parvovirus disease[J]. Animal Industry and Environment, 2023(23): 53-55. (in Chinese)
  9. 9.
    GUO J, CHEN Y H, WANG L R, et al. Non-contact respiratory rate and heart rate signal acquisition system[J]. Opt. Precision Eng., 2019, 27(6): 1354-1361. (in Chinese). doi:
  10. 10.
    CHEN H Y, WANG Z H, MENG L, et al. Design of flexible wearable sensing systems[J]. Journal of Biomedical Engineering, 2023, 40(6): 1071-1083. (in Chinese)
  11. 11.
    DETWEILER D K. The Dog Electrocardiogram: A Critical Review[M]. Comprehensive Electrocardiology. London: Springer London, 2010: 1861-1908. doi:
  12. 12.
    FARMER J B, LEVY G P. A simple method for recording the electrocardiogram and heart rate from conscious animals[J]. British Journal of Pharmacology and Chemotherapy, 1968, 32(1): 193-200. doi:
  13. 13.
    GONDER J C, GARD E A, LOTT N E. Electrocardiograms of nine species of nonhuman Primates sedated with ketamine[J]. American Journal of Veterinary Research, 41(6): 972-975. doi:
  14. 14.
    ECKENFELS A, TRIEB G. The normal electrocardiogram of the conscious beagle dog[J]. Toxicology and Applied Pharmacology, 1979, 47(3): 567-584. doi:
  15. 15.
    DOLITTLE. Wearable Pet Health Management Device[EB/OL]. 2022-08-11[2025-02-15].
  16. 16.
    TSUKAMOTO A, SERIZAWA K, SATO R, et al. Vital signs monitoring during injectable and inhalant anesthesia in mice[J]. Exp Anim, 2015, 64(1): 57-64. doi:
  17. 17.
    BAILEY J E, PABLO L S. Anesthetic monitoring and monitoring equipment: application in small exotic pet practice[J]. Seminars in Avian and Exotic Pet Medicine, 1998, 7(1): 53-60. doi:
  18. 18.
    ANGELUCCI A, BIRETTONI F, BUFALARI A, et al. Validation of a wearable system for respiratory rate monitoring in dogs[J]. IEEE Access, 2024, 12: 80308-80316. doi:
  19. 19.
    MENKES A .Pet animal collar for health & vital signs monitoring, alert and diagnosis:US13400595[P].US20130014706A1,[2025-02-16].DOI:.
  20. 20.
    LTD P .Acoustically enhanced pet animal collar for health & vital signs monitoring, alert and diagnosis[P]. US20190289827A1, [2019-06-12].
  21. 21.
    JACKSON R. How to Take Your Pet's Vital Signs: Heart Rate, Respiratory Rate and Body Temperature[EB/OL]. 2024[2025-02-15].
  22. 22.
    KINDIG J R, BEESON T P, CAMPBELL R W, et al. Acoustical performance of the stethoscope: a comparative analysis[J]. American Heart Journal, 1982, 104(2 Pt 1): 269-275. doi:
  23. 23.
    WANG P F, MA Y Y, LIANG F L, et al. Non-contact vital signs monitoring of dog and cat using a UWB radar[J]. Animals, 2020, 10(2): 205. doi:
  24. 24.
    LAI H M, LIU J, LIU H H, et al. Design of time discrimination module in LiDAR receiver[J]. Semiconductor Optoelectronics, 2024, 45(2): 303-307. (in Chinese)
  25. 25.
    YAN Y C, CHEN X S, XUE L Y, et al. Design of frequency scanning interferometry laser ranging system[J]. Acta Optica Sinica, 2024, 44(18): 166-175. (in Chinese)
  26. 26.
    ZYGMUNT M, JAKUBASZEK M, SĘDEK B, et al. Real-time measurement technique of the echo signal magnitude in ToF laser scanners[J]. Measurement, 2023, 208: 112453. doi:
  27. 27.
    YU J, TU P. Research and implementation of laser ranging based on TDC and phase[J]. Techniques of Automation and Applications, 2023, 42(1): 51-54, 68. (in Chinese)
  28. 28.
    ZHAO X, SU Z, LI L P, et al. Research progress of error compensation technology for pulsed laser time-of-flight ranging[J]. Laser & Optoelectronics Progress, 2021, 58(23): 9-18. (in Chinese)
  29. 29.
    REN Y R, ZONG S G, LIANG S Y, et al. Study on the influence of receiver tilt angle and position on the received optical power in underwater laser communication systems[J]. Semiconductor Optoelectronics, 2022, 43(6): 1184-1189. (in Chinese)
  30. 30.
    QI L, GAO C S, LIN L J, et al. A BiCNN-based TOF Ranging Accuracy Compensation Method[J/OL].Semiconductor Optoelectronics,1-7[2025-03-27]. (in Chinese)
  31. 31.
    HAN Y, LI Y Z, JI Z C, et al. Technologies of real-time non-line-of-sight imaging based on time-of-flight array[J]. Opt. Precision Eng., 2025, 33(3): 377-388. (in Chinese)

Читать полностью

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website