Espectrómetro de atenuación de cavidad CO2 con sensibilidad de detección a nivel de ppb

  • role: First author第一作者
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    University of Science and Technology of China, Hefei 230026, China

  • Email:yliu@aiofm.ac.cn
  • Introduction:刘 英(1998-),女,四川宜宾人,博士研究生,2018年于安徽大学获得学士学位,主要从事激光吸收光谱方面的研究。E-mail: yliu@aiofm.ac.cn
LIU Ying12,  
  • Affiliation:

    Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong 999077, China

HU Mai3,  
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

WANG Xingping1,  
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

XU Zhenyu1,  
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

HE Yabai1,  
  • role: Corresponding author通信作者
  • Affiliation:

    Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

  • Email:kanruifeng@aiofm.ac.cn
  • Introduction:阚瑞峰(1977-),男,辽宁锦州人,博士,研究员,2000年于长春理工大学获得学士学位;2003年、2006年于中国科学院安徽光机所分别获得硕士与博士学位,主要从事光学与光谱学方面的研究。E-mail:kanruifeng@aiofm.ac.cn
KAN Ruifeng1*

resumen

El dióxido de carbono (Carbon dioxide, CO2) es el principal gas de efecto invernadero en la atmósfera, caracterizado por una alta concentración de fondo atmosférico y una pequeña variación anual. Por lo tanto, el monitoreo de su concentración con alta precisión es una etapa importante para lograr el objetivo de "doble carbono". Este artículo se basa en la tecnología de espectroscopía de atenuación de cavidad de onda continua y ha construido un dispositivo de detección de gas CO2 con una sensibilidad de hasta ppb. El sistema seleccionó la línea de absorción CO2 con longitud de onda central de 6251.760 cm-1, diseñó una cavidad de Fabry-Pérot de vidrio de cuarzo de ultra alta finesse (>300 000) y un módulo de control de temperatura y presión de alto rendimiento. Las variaciones de temperatura y presión del gas en la cavidad en 24 horas fueron menores a 0.07 ℃ y 15 Pa, respectivamente. Los resultados de la varianza de Allan muestran que el sistema puede alcanzar un límite de detección de 0.7×10-12 cm-1 con un tiempo de integración óptimo de 303 s, correspondiente a una concentración mínima detectable de CO2 de 1.6 ppb. Dentro de un amplio rango de concentraciones de CO2, el coeficiente de correlación lineal de la respuesta del sistema es 0.99994. Finalmente, con un tiempo de respuesta de 10 s, el sistema realizó una observación continua de la concentración de CO2 en la atmósfera durante 2 días, cuyos resultados coincidieron en gran medida con los datos de monitoreo del dispositivo comercial (Picarro, G2401). La desviación relativa después de excluir la interferencia de la respiración humana fue mejor que 6‰. Este sistema se caracteriza por una estructura simple, bajo costo y sensibilidad extremadamente alta, y tendrá amplias perspectivas de aplicación en el campo de monitoreo de gases en trazas.

palabra clave

Detección de CO2;Sensor óptico;Espectroscopía de atenuación de cavidad;Sensibilidad extremadamente alta

References

  1. 1.
    BOUCHER O, BORELLA A, GASSER T, et al. On the contribution of global aviation to the CO2 radiative forcing of climate[J]. Atmospheric Environment, 2021, 267: 118762. doi:
  2. 2.
    LIU W, WEI N N, WANG G H, et al. Quantitative estimation source of urban atmospheric CO2 by carbon isotope composition[J]. Chinese Journal of Environmental Science, 2012, 33(4): 1041-1049.(in Chinese). doi:
  3. 3.
    YUAN F, GAO J, YAO L, et al. Development of highly sensitive balloon-borne methane measurement system based on cavity ringdown spectroscopy[J]. Opt. Precision Eng., 2020, 28(9): 1881-1892.(in Chinese). doi:
  4. 4.
    AI Y K, LI J, LI Q Y, et al. Cavity ringdown spectroscopy of nitric oxide in the ultraviolet region for human breath test[J]. Journal of Breath Research, 2020, 14(3): 037101. doi:
  5. 5.
    MONDAL K, KAIPARA R, RAJAKUMAR B. Investigation of the absorption cross section of phenyl radical and its kinetics with methanol in the gas phase using cavity ring-down spectroscopy and theoretical methodologies[J]. The Journal of Physical Chemistry A, 2019, 123(45): 9682-9692. doi:
  6. 6.
    WANG J N, ZHENG L J, NIU X T, et al. Design and fabrication of a mid-infrared carbon dioxide sensor for the application in greenhouse environment[J]. Optoelectronics Letters, 2016, 12(5): 379-383. doi:
  7. 7.
    ESLER M B, GRIFFITH D W T, WILSON S R, et al. Precision trace gas analysis by FT-IR spectroscopy. 1. simultaneous analysis of CO2, CH4, N2O, and CO in air[J]. Analytical Chemistry, 2000, 72(1): 206-215. doi:
  8. 8.
    LI M X, CHEN B, RUAN J, et al. On-line detection of carbon dioxide in large scale offshore by laser technology[J]. Opt. Precision Eng., 2020, 28(7): 1424-1432.(in Chinese). doi:
  9. 9.
    FUNKE H H, GRISSOM B L, MCGREW C E, et al. Techniques for the measurement of trace moisture in high-purity electronic specialty gases[J]. Review of Scientific Instruments, 2003, 74(9): 3909-3933. doi:
  10. 10.
    ROMANINI D, KACHANOV A A, SADEGHI N, et al. CW cavity ring down spectroscopy[J]. Chemical Physics Letters, 1997, 264(3/4): 316-322. doi:
  11. 11.
    PALDUS B A, JrHARRIS J S, MARTIN J, et al. Laser diode cavity ring-down spectroscopy using acousto-optic modulator stabilization[J]. Journal of Applied Physics, 1997, 82(7): 3199-3204. doi:
  12. 12.
    HAHN J W, YOO Y S, LEE J Y, et al. Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design[J]. Applied Optics, 1999, 38(9): 1859-1866. doi:
  13. 13.
    ORR BJ, HE Y. Rapidly swept continuous-wave cavity-ringdown spectroscopy[J]. Chemical Physics Letters, 2011, 512(1/2/3): 1-20. doi:
  14. 14.
    CHEN B, SUN Y R, ZHOU Z Y, et al. Ultrasensitive, self-calibrated cavity ring-down spectrometer for quantitative trace gas analysis[J]. Applied Optics, 2014, 53(32): 7716. doi:
  15. 15.
    CROSSON E R. A cavity ring-down analyzer for measuring atmospheric levels of methane, carbon dioxide, and water vapor[J]. Applied Physics B, 2008, 92(3): 403-408. doi:
  16. 16.
    WANG J D, YU J, MO Z Q, et al. Multicomponent gas detection based on concise CW-cavity ring-down spectroscopy with a bow-Tie design[J]. Applied Optics, 2019, 58(11): 2773. doi:
  17. 17.
    SONG S M. Continuous Wave Cavity Ring-Down Spectroscopy Device and Trace Methane Detection[D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2019. (in Chinese)
  18. 18.
    GUO R M, TENG J H, CAO K, et al. Comb-assisted, Pound-Drever-Hall locked cavity ring-down spectrometer for high-performance retrieval of transition parameters[J]. Optics Express, 2019, 27(22): 31850. doi:
  19. 19.
    MA G S, LIU Y, DENG H, et al. High finesse optical feedback cavity ringdown spectroscopy[J]. Opt. Precision Eng., 2022, 30(19): 2305-2312. (in Chinese). doi:
  20. 20.
    BURKART J, ROMANINI D, KASSI S. Optical feedback frequency stabilized cavity ring-down spectroscopy[J]. Optics Letters, 2014, 39(16): 4695. doi:
  21. 21.
    HU M, CHEN X, ZHANG H, et al. Fast optical cavity ring-down spectroscopy detection based on first harmonic frequency locking[J]. Opt. Precision Eng., 2022, 30(4): 363-371. (in Chinese). doi:

Leer el texto completo

The above content is generated by Large Model Translation. The translated content is for reference only. We do not assume any commercial or legal responsibilty for any consequences arising from the use of our website