Investigación de la tecnología de medición del desplazamiento central basada en interferometría heterodina de campo completo

  • role: First author第一作者
  • Affiliation:

    Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing 100094,China

    School of Optoelectronics,University of Chinese Academy of Sciences,Beijing 100049,China

  • Email:yangyongkang22@mails.ucas.ac.cn
  • Introduction:杨永康(2001-),男,河南开封人,硕士研究生,2021年于华中科技大学获得学士学位,主要从事激光干涉测量方面的研究。 E-mail:yangyongkang22@mails.ucas.ac.cn
YANG Yongkang12,  
  • Affiliation:

    Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing 100094,China

LIU Anqi1,  
  • role: Corresponding author通信作者
  • Affiliation:

    Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing 100094,China

    School of Optoelectronics,University of Chinese Academy of Sciences,Beijing 100049,China

  • Email:zhangwenxi@aoe.ac.cn
  • Introduction:张文喜(1979-),男,安徽宿州人,博士,研究员,博士生导师,2003年于中国科学技术大学获得学士学位,2006年于中国科学院西安光学与精密机械研究所获得硕士学位,2014年于中国科学院大学获得博士学位,主要从事三维精密测量、激光干涉测量和振动测量的研究。 E-mail: zhangwenxi@aoe.ac.cn
ZHANG Wenxi12*,  
  • Affiliation:

    Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing 100094,China

    School of Optoelectronics,University of Chinese Academy of Sciences,Beijing 100049,China

WU Zhou12

resumen

Para satisfacer la creciente demanda de precisión en la medición del desplazamiento central de lentes ópticas, este artículo propone un método de medición del desplazamiento central basado en interferometría heterodina de campo completo. Este método utiliza el eje óptico real de la lente como referencia de medición, obteniendo el frente de onda mediante la medición de las franjas de interferencia generadas por el haz reflejado de la lente bajo prueba y el haz de referencia, y realizando un ajuste de polinomios de Zernike. Luego, los coeficientes de los términos de inclinación de Zernike se convierten en el desplazamiento central de la lente bajo prueba, logrando una medición de alta precisión y eliminando la dependencia de una mesa giratoria externa. Basado en el principio de interferometría heterodina y detección del desplazamiento central, se analiza el impacto de las fluctuaciones de intensidad de láser y frecuencia heterodina en el frente de onda y los resultados de medición. Los resultados muestran que el error de medición se correlaciona positivamente con las fluctuaciones de intensidad del láser y frecuencia heterodina, y está influenciado por la curvatura de la lente y el desplazamiento central. Se construyó un sistema de medición del desplazamiento central basado en interferometría heterodina, logrando una medición precisa y comparándola con resultados de simulación. Los resultados de simulación muestran que la precisión de medición del sistema no es inferior a 0.06″, y los resultados fueron validados experimentalmente. Los resultados indican que, en comparación con los métodos tradicionales de medición del desplazamiento central por autocollimación, el método de interferometría heterodina puede lograr una mayor precisión de medición.

palabra clave

interferometría heterodina; medición por interferencia; desplazamiento central; equipos de ajuste

References

  1. 1.
    LI W J, ZHOU J Y, LIN Q H. Design of fold laser projection lithography lens[J]. Opto-Electronic Engineering, 2007, 34(9): 46. (in Chinese)
  2. 2.
    QI M, LI H, GUO Z D, et al. Center offset error of aspheric transmission type optical system aberration[J]. Optics & Optoelectronic Technology, 2022, 20(2): 134-139. (in Chinese). doi:
  3. 3.
    GUO B H. Research on Optical Lens-Aided Assembly and Adjustment Equipment based on Mirror Interval and Center Deviation Measurement[D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2014. (in Chinese)
  4. 4.
    BEIER M, GEBHARDT A, EBERHARDT R, et al. Lens centering of aspheres for high-quality optics[J]. Advanced Optical Technologies, 2012, 1(6): 441-446. doi:
  5. 5.
    GREEN M E, GARDEN R P. Active alignment technique for measuring tilt errors in aspheric surfaces during optical assembly using lens alignment station (LAS): US11391564[P]. 2022-07-19. doi:
  6. 6.
    OYA N, RUPRECHT A, DUMITRESCU E. Measurement of the positions of centres of curvature of optical surfaces of a single or multi-lens optical system: US9863844[P]. 2018-01-09.
  7. 7.
    LANGEHANENBERG P, STUDER J, BERIŠA K. Complete and efficient opto-mechanical characterization of IR lens assemblies[C]. Dimensional Optical Metrology and Inspection for Practical Applications XI. SPIE, 2022: PC1209806.
  8. 8.
    WANG W, DU Z, CHENG R, et al. Automatic measurement of center deviation of lens of laser differential confocal[J]. Opt. Precision Eng.,2023,31(23):3405-3413. (in Chinese). doi:
  9. 9.
    ZHUANG Y G, ZHANG G W, ZHAO W Q, et al. Differential confocal radius of curvature measurement method for five-dimensional position monitoring[J]. Opt. Precision Eng.,2023, 31(7):975-981. (in Chinese). doi:
  10. 10.
    HOPKINS H H, TIZIANI H J. A theoretical and experimental study of lens centring errors and their influence on optical image quality[J]. British Journal of Applied Physics, 1966, 17(1): 33-54. doi:
  11. 11.
    YUN Z X. General situation of eccentric testing instruments[J]. Journal of Xi'An Institute of Technology, 1984, 4(2): 65-72. (in Chinese)
  12. 12.
    GE H, WANG Y, QIU L R. Confocal self-collimation decentration measurement structure with high accuracy[J]. Optical Technique, 2018, 44(6): 681-685. (in Chinese)
  13. 13.
    LUO J, LIU Z H, LIU Y J, et al. Differential confocal profile tracking measurement method based on Kalman prediction[J]. Chinese Journal of Scientific Instrument, 2023, 44(3): 25-32. (in Chinese)
  14. 14.
    WU Z, LI Y, XIANGLI B, et al. Full-field heterodyne long-cavity interferometry[J]. Acta Optica Sinica, 2019, 39(9): 0912003. (in Chinese). doi:
  15. 15.
    FAN G X, LI Y, ZHANG W X, et al.. Full-field heterodyne phase shifting two-wavelength interferometry surface testing technologies[J]. Infrared and Laser Engineering,2022,51(9):132-140. (in Chinese)
  16. 16.
    LI X H, CUI C. Grating interferometric precision nanometric measurement technology[J]. Opt. Precision Eng., 2024, 32(17): 2591-2611. (in Chinese). doi:
  17. 17.
    MALACARA D. Optical Shop Testing[M]. Hoboken, NJ: Wiley, 2007. doi:
  18. 18.
    MILLSTONE D B. Edge Response Characteriza⁃ tion of Interferometers and the Effect of Aberrations [D]. Arizona: The University of Arizona, 2017.

Leer el texto completo