CHI Xue-fen, HAN Chang-yuan. Assessment of sampled imaging system based on information-theory[J]. Editorial Office of Optics and Precision Engineering, 2003,(2): 207-211
CHI Xue-fen, HAN Chang-yuan. Assessment of sampled imaging system based on information-theory[J]. Editorial Office of Optics and Precision Engineering, 2003,(2): 207-211DOI:
Assessment of sampled imaging system based on information-theory
The theoretical basis for assessment of a sampled imaging system based on information theory is discussed
and the optical and image information processing methods are examined. The integrated optical and electronic designs of the sampled imaging system are proposed. The confusion in images is reduced and the quality of image is improved by matching an optical imagery system with a CCD detection system.
关键词
Keywords
references
HUCK F O, PARK S K. Optical-mechanical line-scan imaging process: Its information capacity and efficiency[J]. Applied Optics,1975,14(10): 2508-2520.
FALES C L, HUCK F O, SAMMS R W. Imaging design for improved information capacity[J]. Applied Optics,1984,23(6): 872-888.
HUCK F O, FALES C L. Image gathering and processing: information and fidelity[J]. Journal of Optical Society of America A,1985,2(10): 1644-1666.
COX I J, SHEPPARD C J R. Information capacity and resolution in an optical system[J].Journal of Optical Society of America A,1986,3(8): 1152-1158.
HUCK F O, FALES C L, MCCORMICK J A,et al. Image-gathering system design for information and fidelity[J].J Opt Soc Am,1988,5(3): 285-299.
JONE S, RAHMAN Z, HUCK F O,et al. Information theoretical assessment of digital image system[J].Optical Engineering,1990,1309:53-66.
TORRIBA R, RABAL H, RUIZ B. An entropy approach to light propagation[J]. Journal of Modern Optics,1992,39(9):1939-1946.
CARRETERP L, FIMIA A. Enteopy-based study of imaging quality holographic optical element[J].Optical Society of Am,1994,19(17): 1355-1357.
HUCK F O, FALES C L,GARTENBERG R L,et al. Information-theoretical assessment of sampled imaging systems[J].Optical Engineering,1999,38(5):742-762.
CHOU W CH, NEIFELD M A. Information-based optical design for binary-valued imagery[J].Applied Optics,2000,39(11): 1731-1742.
JOHNSON K, COLE-RHODS A, MOIGNE J L, et al. Multi-resolution image resolution of remotely sensed imagery using Mutual information[J]. SPIE,2001,4391:330-339.
李佳列,丁国清,颜国正,等.采用CCD的非接触测量中提高精度的一种方法[J].光学精密工程,2002,10(3):281-284.LI J L, DING G Q, YAN G ZH, et al. Method for improving precision in noncontact measurement by linear CCD[J]. Optical and Precision Engineering,2002,10(3):281-284.
丁延卫,刘剑,卢锷.空间环境对光学成像遥感器尺寸稳定性的影响[J].光学精密工程,2002,10(1): 106-109.DING Y W, LIU J, LU E. Effect of space environment on the dimension stability of optical remote sensor[J].Optical and Precision Engineering,2002,10(1):106-109.
张明慧,徐为,张尧禹,等.航空照片的图像增强研究[J].光学精密工程,2002,10(2):194-200.ZANG M H, XU W, ZHANG Y Y, et al. Research on image enhancing for aerial photographs[J]. Optical and Precision Engineering,2002,10 (2):194-200.
迟学芬,韩昌元. 采样目标统计特性与CCD探测系统设计[J].吉林大学学报,2002,20(4):23-26.CHI X F, HAN CH Y. The design methods of CCD detection system and the statistical characteristics of sampled targets[J]. Journal of Jilin University,2002,20(4):23-36.
迟学芬,石文孝,韩昌元,等.基于信息理论的采样成像系统优化设计[J].通信学报,2002,23(9): 88-93.CHI X F, SHI W X, HAN CH Y, et al. Information-theory based optimizing design methods in sampled-imaging system[J].Journal of China Institute of Communications,2002,23(9):88-93.
PARK S K,RAHMAN Z. Fidelity analysis of sampled imaging systems[J]. Optical Engineering,1999,38(5):786-800.
VOLLMERHAUSEN R, DRIGGERS R G, O'KANE B L. Influence of sampling on target recognition and identification[J].Optical Engineering,1999,38(5): 763-772.
PARK S K, RAHMAN Z. Fidelity analysis of sampled imaging systems[J].Optical Engineering,1999,38(5):786-800.
BRADY D, NEIFELD M A. Information theory in optoelectronic systems: introduction to the feature[J]. Applied Optics,2000,39(11):1679-1680.
ALTER-GARTENBERG R. Information metric as a design tool for optoelectronic imaging system[J]. Applied Optics,2000,39(11):1743-1760.