WANG Lin-dou, WANG Jia-xin, XING Wen-lie, LI Yu-feng. Laser interferometer with isolator function[J]. Editorial Office of Optics and Precision Engineering, 2004,(5): 465-470
WANG Lin-dou, WANG Jia-xin, XING Wen-lie, LI Yu-feng. Laser interferometer with isolator function[J]. Editorial Office of Optics and Precision Engineering, 2004,(5): 465-470DOI:
A laser interferometer with isolator function is proposed. It can be used to carry out interference measurement
and at the same time can be prevent reflected light from returning into the laser source to stabilize the source as an isolator does
thus the measurement accuracy can be guaranteed. So
the structure of the device is formed by organic combing two structures of the conventional interferometer and two-stage isolator
in which some elements can be combined two into one with double function. And the optical paths of the interference measurement and isolating are overlapped. Theoretic analysis and experiment results show that the device is effective
the isolation is agrees with that of a two-stage isolator
about 48 dB up to now. The results also show that the accuracy of the interference measurement depends on the wavelength of the laser like that of the general interferometer. But with compact structure
it simplifies the measurement system and is convenient for practical uses.
关键词
Keywords
references
SUN C K, YE S H.Laser measurement techniques [M] . Tianjin: Tianjin Univ. press, 2001.(in Chinese)
DING J H, CUI Y S, WU M J.Laser principle and application [M] . Beijing: Tsing-Hua Univ. press, 1987.(in Chinese)
SONG K,ZHAO Y L,JIANG Z D.Laser profilometer[J] . Optics and Precision Engineering,2003,11(3):245-249.(in Chinese)
LI C,ZHANG Y M,TIAN X F,WU S.Optical design for wedg-adjusted Talbot interferometer[J] . Optics and Precision Engineering, 2003,11(5):453-456.(in Chinese)
HONG H T,YE S H.Research on the positioning method for interferometer system of absolute distance measurement[J] . Optics and Precision Engineering, 1999,7(1):110-115.(in Chinese)
GREEN A E,GEORGIOU G. Compact bulk optical isolator with monomode fibre pigtails for use at 1.3 μm[J] .Electronics Letters, 1986,22(20):1045-1046.
MATSUMOTO S, SUZUKI S. Temperature-stable Faraday rotator material and its use in high-performance optical isolators[J] .Appl. Opt., 1986, 25(12):1940-1945.
YOKOI H,MIZUMOTO T,SHINJO N, et al. Feasibility of integrated optical isolator with semiconductor guiding layer fabricated by wafer direct bonding[J] . IEEE Proc-Optoecectron, 1999,146(2):105-109.
BAHLMANN N,LOHMEYER M,D otsch, et al.Integrated magneto-optic Mach-Zehnder interferometer isolator for TE modes[J] . Electronics Letters,1998,34(22):2122-2123.
KOGA M, MATSUMOTO T. High-isolation polarization-insensitive optical circulator for advanced optical communication systems[J] .J. Lightwave Technol., 1992, 10(9): 1210-1217.
CHANG K W, SORIN W V. High-performance single-mode fiber polarization-independent isolators[J] .Opt. Lett.,1999,15(8): 449-451.
WANG L D, ZHU S X, LI Y F, et al. Accurate Jones matrix of the practical Faraday rotator[J] .Trans. of Tianjin Univ., 2003, 9(3):198-201.