

浏览全部资源
扫码关注微信
1. School of Electronic and Information Engineering, Dalian University of Technology Dalian,China,116024
2. College of Information Technology,Dalian Maritime University Dalian,China,116026
Received:16 March 2005,
Revised:27 June 2005,
Published Online:30 October 2005,
Published:30 October 2005
移动端阅览
HU Jia-sheng, WU Xü. Manufacturing and testing of X-ray imaging components with high precision[J]. Optics and precision engineering, 2005, 13(5): 620-625.
In the latest 20 years
X-ray imaging technology has developed rapidly in order to meet the needs of X-ray photo-etching
spatial exploration technology
high-energy physics
procedure diagnosis of ICF
etc. Since refractive indices of materials in the X-ray region are lower than 1
and X-ray is strongly absorbed by materials
the characteristics of X-ray increase greatly difficulty to obtain X-ray image. Conventional imaging methods are hardly suitable to X-ray range. In general
grazing reflective imaging and coding aperture imaging methods have been adopted more and more.We have designed a non-coaxial grazing reflective X-ray microscope which is composed of four spherical mirrors
in order to satisfy the requirement of the diagnosis of inertial confinement fusion (ICF). The four mirrors have the same radius of curvature. The radius of each mirror is 29 000 mm and the aperture is 30 mm×15 mm. Allowable tolerance of the radius is ≤0.2% and one of surface roughness (rms) is ≤0.6 nm. Evidently it is very difficult to fabricate and test such mirrors. In order to obtain eligible mirrors
we choose 18 mirror roughcasts and array them on a round disk according to format. The combined manufacturing method can ensure high accordant quality. The fabricated mirrors are tested by both templet and double round aperture methods. Radius errors of the mirrors is about 53 mm. The surface roughness (rms) of the mirrors is inspected by the relative interferometric equipment (WYKO) and atomic force microscope. Before and after coating the measured surface roughness is averagely 0.52 nm and 0.4 nm
respectively.
In the latest 20 years
X-ray imaging technology has developed rapidly in order to meet the needs of X-ray photo-etching
spatial exploration technology
high-energy physics
procedure diagnosis of ICF
etc. Since refractive indices of materials in the X-ray region are lower than 1
and X-ray is strongly absorbed by materials
the characteristics of X-ray increase greatly difficulty to obtain X-ray image. Conventional imaging methods are hardly suitable to X-ray range. In general
grazing reflective imaging and coding aperture imaging methods have been adopted more and more.We have designed a non-coaxial grazing reflective X-ray microscope which is composed of four spherical mirrors
in order to satisfy the requirement of the diagnosis of inertial confinement fusion (ICF). The four mirrors have the same radius of curvature. The radius of each mirror is 29 000 mm and the aperture is 30 mm×15 mm. Allowable tolerance of the radius is ≤0.2% and one of surface roughness (rms) is ≤0.6 nm. Evidently it is very difficult to fabricate and test such mirrors. In order to obtain eligible mirrors
we choose 18 mirror roughcasts and array them on a round disk according to format. The combined manufacturing method can ensure high accordant quality. The fabricated mirrors are tested by both templet and double round aperture methods. Radius errors of the mirrors is about 53 mm. The surface roughness (rms) of the mirrors is inspected by the relative interferometric equipment (WYKO) and atomic force microscope. Before and after coating the measured surface roughness is averagely 0.52 nm and 0.4 nm
respectively.
. COMPTON A H. Philos.Mag[Z].1923.
. SUZUKI Y.X-ray microscope with a pair of elliptical mirrors[J]. Japaness Journal of Applied Physics,1989,28(9):L1660-L1662.
. KODAMA R.Development of a Kirkpatric-Baez microscope with a large visual field[J].SPIE,1995,2523:165-173.
. SAUNEUF R.Large-field high-resolution X-ray microscope for studying laser plasmas[J].Rev. Sci. Instrum,1997,68(9):3412-3420.
. HU J SH,ZHAO L L,LI X. Design and analysis of X-ray microscope of four mirrors working at grazing incidence[J]. Journal of Optoelectronics Laser,2005,16(3).(in Chinese)
. HU J SH,ZHAO L L,LI X,WU X,BAI Y H. Imaging quality analysis of KBA X-ray microscope working at grazing incidence[J].SPIE,2004, 5638:955-960.
. HU J SH. Introduction to optical engineering[M].Dalian University of Technology Press, Dalian, China, 2002:158-164.(in Chinese)
0
Views
497
下载量
4
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621