Imaging research of two kinds of sparse-aperture systems
|更新时间:2020-08-12
|
Imaging research of two kinds of sparse-aperture systems
Optics and Precision EngineeringVol. 14, Issue 1, Pages: 26-33(2006)
作者机构:
1. 苏州科技学院 实验中心,江苏苏州215009
2. 苏州大学 江苏省现代光学技术重点实 验室,江苏 苏州 215006
3. 苏州大学 物理科学与技术学院光电系,江苏 苏州 215006
作者简介:
基金信息:
DOI:
CLC:TP73;TH703
Received:22 December 2005,
Revised:25 December 2005,
Published Online:20 February 2006,
Published:20 February 2006
稿件说明:
移动端阅览
WU Quan-ying, QIAN Lin, SHEN Wei-min. Imaging research of two kinds of sparse-aperture systems[J]. Optics and precision engineering, 2006, 14(1): 26-33.
DOI:
WU Quan-ying, QIAN Lin, SHEN Wei-min. Imaging research of two kinds of sparse-aperture systems[J]. Optics and precision engineering, 2006, 14(1): 26-33.DOI:
Imaging research of two kinds of sparse-aperture systems
A sparse aperture configuration named dual three sub-apertures composed of nine sub-apertures was introduced and the models of configuration were described. The dual three sub-apertures system was compared with the GOLAY 9
which composed of nine sub-apertures
to research the imaging of two kinds of sparse aperture systems. The comparison of their characteristics and modulation transfer functions (MTF) with the dual three sub-apertures and the GOLAY 9 were given. The equivalent diameters and the practical equivalent diameters of two kinds of sparse aperture systems were calculated
and the image simulations and Wiener filtered images of two kinds of sparse aperture systems with different fill factors were shown. Their image quality was evaluated with their standard deviation (std) and image contrast. Through the comparison
it is shown that the MTF of the dual three sub-apertures is obviously higher than that of the GOLAY 9 at the direction of maximal MTF except at the normalized spatial frequency between 0.55 to 0.65. When the fill factor is not smaller than 20%
the equivalent diameters and the practical equivalent diameters of two kinds of sparse aperture systems are almost equal. The image quality of the dual three sub-apertures is better than that of the GOLAY 9 at the spatial frequency between 24~45 lp/mm. The performance of the dual three sub-apertures is almost same as the GOLAY 9. The dual three sub-apertures system has the advantages of symmetric configuration and easy fabrication.
关键词
Keywords
references
. 王海涛,周必方. 天文光干涉技术[J]. 光学 精密工程,2003, 11(4): 320-325. WANG H T,ZHOU B F. Astronomical optical interference technology . Optics and Precision Engineering, 2003,11(4) : 320-325 .(in Chinese)
. 王海涛,周必方. 光学综合孔径干涉成像技术[J]. 光学 精密工程,2002, 10(5): 434-442. WANG H T,ZHOU B F. Optical synthesis aperture interference image technology[J]. Optics and Precision Engineering, 2002,10(5) : 434-442.(in Chinese)
. FIETE R D,TANTALO T A. Image quality of sparse-aperture designs for remote sensing [J]. Optical Engineering, 2002, 41 (8): 1957-1968.
. MEINEL A B,MEINEL M P. Large sparse-aperture space optical systems[J]. Optical Engineering, 2002, 41 (8): 1983-1994 .
. 钱霖, 吴泉英, 吴锋, 等. 复合三子镜的成像研究[J]. 光学学报,2005, 25(8):1030-1035. QIAN L, WU Q Y, WU F, et al. Study on sparse-aperture imaging of dual three sub-apertures design [J].Acta Optica Sinica , 2005, 25(8):1030-1035.(in Chinese)
. HARVEY J E,ROCKWELL R A. Performance characteristics of phased array and thinned aperture optical telescopes[J].Optical Engineering, 1998,27 (9): 762-768.
. ZHENG Y F,CUI X H. CT scout Z-resolution improvement with image restoration methods[J].SPIE,2003,5032:1851-1857.
. WU Q Y,QIAN L,SHEN W M. Image recovering for sparse-aperture systems [J]. SPIE, 2005, 5642:478-486.
. 吴泉英,钱霖,沈为民. 稀疏孔径系统的成像和图像复原研究[J]. 激光杂志,2005,26(6):40-42. WU Q Y,QIAN L,SHEN W M. Imaging and image recovering of sparse-aperture systems[J]. Laser Joumal,2005,26(6):40-42.(in Chinese)
. GUAN L,WARD R K. Restoration of stochastically blurred images by the geometrical mean filter[J]. Optical Engineering, 1990, 29 (4): 289-295.