A new algorithm for human eye’s wave-front aberration fitting with Zernike polynomial
|更新时间:2020-08-12
|
A new algorithm for human eye’s wave-front aberration fitting with Zernike polynomial
Optics and Precision EngineeringVol. 14, Issue 2, Pages: 308-314(2006)
作者机构:
南京航空航天大学 机电学院,江苏 南京,210016
作者简介:
基金信息:
DOI:
CLC:R778.2;TP391
Received:15 June 2005,
Revised:14 December 2005,
Published Online:30 April 2006,
Published:30 April 2006
稿件说明:
移动端阅览
CAO Zheng-lin, LIAO Wen-he, SHEN Jian-xin. A new algorithm for human eye’s wave-front aberration fitting with Zernike polynomial[J]. Optics and precision engineering, 2006, 14(2): 308-314.
DOI:
CAO Zheng-lin, LIAO Wen-he, SHEN Jian-xin. A new algorithm for human eye’s wave-front aberration fitting with Zernike polynomial[J]. Optics and precision engineering, 2006, 14(2): 308-314.DOI:
A new algorithm for human eye’s wave-front aberration fitting with Zernike polynomial
A new precise algorithm for computing the fitting coefficients of the Zernike polynomial was presented. The concept of human eye’s aberration and the mathematical function of wave-front aberration expressed by Zernike polynomial were introduced. The matrix of inconsistent equation group of the algorithm was orthogonalized and triangulated by Householder transformation
and the Zernike coefficients were given directly. The fitting coefficients of the Zernike polynomial of the big and small pupil were computed respectively by using this new algorithm and by constructing normal equation group. The computational results show that two algorithms have equivalent computational precision with relative error of each order coefficient in less than 10%. By avoiding the computational error introduced by constructing normal equation group
the algorithm is easy to used in programming and has proved to be an efficacious algorithm.
关键词
Keywords
references
. 叶寒,廖文和,沈建新. 波前像差引导的角膜切削模型及实现技术的研究[J]. 光学 精密工程,2004,12(1):31-36. YE H,LIAO W H,SHEN J X.Wave-front guided ablation on cornea[J].Optics and precision Engineering,2004,12(1):31-36.(in Chinese)
. 张运海,沈建新,廖文和. 准分子激光矫正复性近视散光的屈光学机理及应用[J]. 光学 精密工程,2003,11(3):291-295. ZHANG Y H,SHEN J X,LIAO W T.Use of excimer to correct compound myopic astigmatism[J].Optics and Precision Engineering,2003,11(3):291-295.(in Chinese)
. OSHIKA T,MIYATA K,TOKUNAGA T,et al. Higher order wave-front aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusis[J]. Ophthalmology 2002, 109(6):1154-1158.
. BARRIUSO E M,LLOVES J ,MARCOS S, et al. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing[J]. Investigative Ophthalmology & Visual Science, 2001, 42(6):1396-1403.
. HAMENT W J,NABAR V A,NUIJTS R M M A. Repeatability and validity of Zywave aberrometer measurements[J]. Journal of Cataract & Refractive Surgery, 2002, 28(12):2135-2141.
. SALMON T,THIBOS L,BRADLEY A. Camparison of the eye’s wave-front aberration measured psychophysically and with the Shack-Hartmann wave-front sensor[J]. J Opt. Soc Am A, 1998,15:2457-2465.
. HOWLAND H C. The history and methods of Ophthalmic wave-front sensing[J]. Journal of Refractive Surgery, 2000,16(9/10):S552-S553.
. THIBOS L N,APPLEGATE R A,SCHWIEGERLING J T, et al. Standards for reporting the optical aberration of eyes[J], Journal of Refractive Surgery,2002,18(5):S652-S665.
. HE J C, MARCOS S. Measurement of the wave-front aberration of the eye by a fast psychophysical procedure[J].J.Opt.Soc.Am.,1998,A15:2449-2455.
. 鄢静舟,孙厚环,高志强,等. 用Zernike多项式进行波面拟合的一种新算法[J]. 数学物理学报,2000,20(3):378-385. YAN J ZH,SUN H H,GAO ZH Q,et al.A new algorithm for wave-front fitting using Zernike polynomial[J].Acta Mathematica Scientia,2000,20(3):378-385.(in Chinese)