Study on dynamic imaging on push-broom TDI CCD optical remote sensor
|更新时间:2020-08-12
|
Study on dynamic imaging on push-broom TDI CCD optical remote sensor
Optics and Precision EngineeringVol. 14, Issue 2, Pages: 291-296(2006)
作者机构:
1. 中国科学院 长春光学精密机械与物理研究所,吉林 长春,中国,130033
2. 中国科学院 研究生院 北京,100039
作者简介:
基金信息:
DOI:
CLC:TP73
Received:22 November 2005,
Revised:18 December 2006,
Published Online:30 April 2006,
Published:30 April 2006
稿件说明:
移动端阅览
ZHAO Gui-jun, CHEN Chang-zheng, WAN Zhi, et al. Study on dynamic imaging on push-broom TDI CCD optical remote sensor[J]. Optics and precision engineering, 2006, 14(2): 291-296.
DOI:
ZHAO Gui-jun, CHEN Chang-zheng, WAN Zhi, et al. Study on dynamic imaging on push-broom TDI CCD optical remote sensor[J]. Optics and precision engineering, 2006, 14(2): 291-296.DOI:
Study on dynamic imaging on push-broom TDI CCD optical remote sensor
For the dynamic imaging test of push-broom TDI CCD (Time Delay Integration Charge Coupled Devices) space optical remote sensor
a kind of special test system was designed. A precise rotary platform with dual bearing and a U type frame was designed to simulate the satellite push-broom in the system. Within ±5° range it could be turned at the angle rate of 0.555°/s with rotary precision of 0.3% with the remote sensor being carried. A drone at Nequist Frquency was designed in which bar target in
a/n
tolerance of arithmetical progression was added between each group rectangle vertical bar in the drone. When the remote sensor worked under push-broom mode
the problem of the matching uncertainty between the target image and the CCD pixel be solved
which could simplify the registration and improve the measuring accuracy. The results prove that the drone image can be obtained at the Nequist Frquency in the field of view of 0 and ±0.86 in the vertical
horizontal and 45°directions. TDI CCD remote sensor is provided with high imaging quality based on push-broom technique.
关键词
Keywords
references
. BICKNELL W E,DIGENIS C J,FORMAN S E.EO-1 Advanced land imager[J].SPIE,1999,3750:80-88.
. BRET-DIBAT T,ALBOUYS V,BERTHON J.Tests of a high resolution three mirrors anastigmatic telescope[J].SPIE,1999.3870:126-137.
. 佟首峰, 刘金国, 阮锦,等. 推帚式TDI-CCD相机应用分析[J]. 光电工程,2001 ,23 (1) :31-33. TONG SH F, LIU J G, RUAN J,et al.An analysis for application technique of push-broom TDI-CCD imaging camera[J].Opto-Electronic Engineering,2001 ,23 (1) :31-33.(in Chinese)
. 陶家生.基于模拟实验及计算机仿真的CCD航天相机影像分辨力的研究 . 中国科学院研究生院博士学位论文,2003.9:26-39. TAO J SH. The study of imaging quality and resolution of CCD space camera base on model experiment and computer emulation .Ph.D thesis, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2003:(9)26-39.(in Chinese)
. 吴宏圣,潘凝. TDI CCD全景式航空相机的像移补偿误差分析[J]. 光学 精密工程,2003, 11(6):545-549. WU H SH,PAN N. Image motion compensation error analysis for TDI CCD panoramic aerial camera[J]. Optics and Precision Engineering,2003,11(6):545-549.(in Chinese)
. 杨秉新. TDI CCD在航天遥感器中的应用[J]. 航天返回与遥感,1997,18(3):15-18. YANG B X. Application of TDI CCD in space image sensor[J].Spacecraft Recovery and Remote Sensing,1997,18(3):15-18.(in Chinese)
. HOST G C.CCD Arrays cameras and displays .SPIE Optical Engineering Press,1998:280-283.
. 郝云彩. 线阵CCD相机试验室像质测试的配准方法研究[J]. 航天返回与遥感, 1999.9, 20(3):27-30. HAO Y C. Research on the registration for image quality test in laboratory of the linear array CCD camera[J].Spacecraft Recovery and Remote Sensing, 1999.9, 20(3):27-30.(in Chinese)