FENG Yu-tao, XIANG Yang. Effect of spectral curvature on signal acquisition of imaging spectrometer with prism dispersion in VNIR[J]. Editorial Office of Optics and Precision Engineering, 2009,17(1): 20-25
FENG Yu-tao, XIANG Yang. Effect of spectral curvature on signal acquisition of imaging spectrometer with prism dispersion in VNIR[J]. Editorial Office of Optics and Precision Engineering, 2009,17(1): 20-25DOI:
Effect of spectral curvature on signal acquisition of imaging spectrometer with prism dispersion in VNIR
To study the effect of spectral curvature on the acquired radiant signal by imaging spectrometer with prism dispersion
the errors of acquired signal between with spectral offset 0.01
0.05
0.1
d
(
d
is pixel dimension) and without spectral curvature was calculated by combining with the dispersive characteristics of composite prism in Visible-Near Infrared VNIR (400~1 000 m). The experimental results indicate that the scene radiant signal acquired by imaging spectrometer with spectral line bend exhibits distinct errors at the edges of atmospherical absorption bands compared with no spectral curvature
and the normalized signal errors increase with the spectral offset. When spectral resolution increases
there are distinct signal errors near some weak atmospherical absorption peaks. These results reported here suggest that spectral curvature should be no more than 0.3 nm for imaging spectrometer with 10 nm resolution.
关键词
Keywords
references
李幼平,禹秉熙,韩昌元,等. 成像光谱仪工程权衡优化设计的光学结构[J]. 光学 精密工程, 2006,14(6):974-979. LI Y P, YU B X , HAN CH Y, et al.. Tradeoff optimization design of optical configuration on imaging spectrometer[J]. Opt. Precision Eng., 2006, 14(6): 274-279. (in Chinese)[2] 于斌,曹召良,禹秉熙. 二元光学透镜在超光谱成像仪中的应用[J]. 光学 精密工程, 2003,11(2):157-161. YU B, CAO ZH L, YU B X. Application of binary optical lens in hyperspectral imager[J]. Opt. Precision Eng., 2003, 11(2): 157-161. (in Chinese)[3] WILLOUGHBY C T, ARMO J M, FOLKMAN M A. Hyperspectral imaging payload for the NASA small satellite technology initiative program [J]. IEEE, 1996, 2: 67-76.[4] DAVIS C O. A spaceborne imaging spectrometer for environmental assessment of the coastal ocean[J]. SPIE, 1996, 2817: 224-230.[5] FOLKMAN M, PEARIMAN J. EO-1/Hyperion hyperspectral imager design, development, characterization, and calibration [J]. SPIE, 2001, 4151: 40-50.[6] OTTEN III L J, SELLAR R G, RAFERT J B. MightySat Fourier transform hyperspectral imager payload performance [J]. SPIE, 1995, 2583: 566-575.[7] BLECHINGER F, HARNISCH B, KUNKEL B. Optical concepts for high resolution imaging spectrometers [J]. SPIE, 1995, 2480: 165-179. [8] DAVIS C O, BOWLES J, LEATHERS R A, et al.. Ocean PHILLS hyperspectral imager: design, characterization, and calibration [J]. Optics Express, 2002, 10(4): 210-221.[9] GREEN R O. Spectral calibration requirement for earth-looking imaging spectrometers in the solar-reflected spectrum [J]. Applied Optics, 1998, 37(4): 683-690.[10] COOKE B J, BRYAN E L,CHRISTOPH C B. Methodology for rapid infrared multi-spectral, electro-optical imaging system performance analysis and synthesis [J]. SPIE, 1996, 2743: 52-86.[11] 李幼平, 禹秉熙, 王玉鹏,等. 成像光谱仪辐射定标影响量的测量链与不确定度[J]. 光学 精密工程, 2006,14(5):822-828. LI Y P,YU B X ,WANG Y P,et al.. Measurement chain of influence quantities and uncertainty of radiometric calibration for imaging spectrometer [J]. Opt. Precision Eng., 2006,14(5): 822-828. (in Chinese)[12] NEVILLE R, SUNB A, STAENZA L K. Detection of spectral line curvature in imaging spectrometer data [J]. SPIE,2003, 5093: 144-154.[13] MOUROULIS P, MCKERNS M M. Pushbroom imaging spectrometer with high spectroscopic data fidelity: experimental demonstration [J]. Opt. Eng., 2000, 39 (3):808-816.[14] MOUROULIS P, GREEN R O, CHRIEN T G. Design of pushbroom imaging spectrometers for optimum recovery of spectroscopic and spatial information [J]. Applied Optics, 2000, 39(13): 2210-2220.