TAN Xin, LIU Ying, XU Xiang-dong, HONG Yi-lin, FU Shao-jun. 13.9 nm Laminar grating as beam splitter[J]. Editorial Office of Optics and Precision Engineering, 2009,17(1): 33-37
TAN Xin, LIU Ying, XU Xiang-dong, HONG Yi-lin, FU Shao-jun. 13.9 nm Laminar grating as beam splitter[J]. Editorial Office of Optics and Precision Engineering, 2009,17(1): 33-37DOI:
A Laminar grating with a 1 000 lp/mm rectangular Laminar groove profile
13 nm groove depth and a 0.43 duty cycle is fabricated by holographic ion beam etching. The grating is coated by Au in thickness of 40 nm. When the work wavelength is 13.9 nm
the product of the zero order and the first order light diffractions is close to 8.1% at an incident angle of 81.2
and the diffraction efficiencies of the zero order and the first order are approximately equal. Experimental results illustrate the potential of Laminar grating as a beam splitter at 13.9 nm and also show its efficiency can be higher than 7%.
关键词
Keywords
references
王占山,吴永刚,唐伟星,等. 软X射线激光用分束镜研制[J]. 科学通报,2003,48(13):1398-1401. WANG ZH S, WU Y G, TANG W X, et al.. Study on soft x-ray laser splitter[J]. China Science Bulletin, 2003,48(13):1398-1401.(in Chinese)[2] BRACEWELL R N. Fourier Transform and Its Applications[M]. New York: McGraw-Hill, 1965.[3] DA SILVA L B, BARBEE JR T W, CAUBRE R. Electron density measurements of high density plasmas using soft X-ray laser interferometry [J]. Phys. Rev. Lett., 1995,74(20):3991-3994.[4] MACCHIETTO C D, BENWARE B R, ROCCA J J. Generation of millijoule-level soft X-ray laser pulses at 4-Hz repetition rate in a highly saturated table-top capillary discharge amplifier[J]. Opt. Lett., 1999,24(16):1115-1117.[5] LI Y, DUNN J, NILSEN J, et al.. Saturated tabletop X-ray system at 19 nm[J]. J. Opt. Soc.Am. B,2000,17(16):1098–1101.[6] SMITH R F, DUNN J, NILSEN J, et al.. Picosecond X-ray laser interometry of dense plasmas[J]. Phy. Rev. Lett., 2002,89:065004-01-065004-04.[7] SMITH R F, DUNN J, NILSEN J, et al.. Refraction effects on x-ray and ultravillet interferometric[J]. J. Opt. Soc. Am. B, 2003,20(1):254-259. [8] FILEVICH J, ROCCA J J, MARCONI M C, et al.. Picosecond-resolution soft-x-ray laser plasma interferometry[J]. Appl. Opt.,2004,43(19):3938-3946.[9] 庄夔,李永贵,胡宁. 消象差超环面全息光栅的设计和制作[J]. 光学 精密工程,1985,(4):285-289. ZHUANG X, LI Y G, HU N. Design and production of aberration-reduced toroidal holographic gratings[J]. Opt.Precision Eng.,1985,(4):285-289. (in Chinese)[10] 庄夔, 刘桂琴, 李永贵. 全息光栅[J]. 光学 精密工程, 1981,(5):226-230. ZHUANG X, LIU G Q , LI Y G. Holographic gratings[J]. Opt. Precision Eng.,1981,(5):226-230. (in Chinese)[11] LIU B, WANG Q P, XU X D, et al.. Measurements of groove density for concave gratings with the long trace profiler[J]. Rev. Sci. Instrum., 2006, 77:046106.[12] 刘斌,王秋平,徐向东,等. 压弯光栅线密度变化分析 . 光学精密工程, 2006, 14(2):224-228. LIU B, WANG Q , XU X, et al.. Analysis of groove density for diffraction grating during bending[J]. Opt. Precision Eng., 2006, 14(2):224-228. (in Chinese)[13] 刘斌,王秋平,付绍军. 长程大型非球面轮廓测量仪的研究[J]. 激光与光电子学进展,2006, 42(2):46-53. LIU B, WANG Q, FU S. Investigation of long trace profiler for aspherical optics[J]. Laser & Optoelectronics Progress, 2006, 42(2):46-53. (in Chinese)