LIU Bing-guo, LIU Guo-dong, PU Zhao-bang, ZHUANG Zhi-Tao, CHEN Feng-Dong. Measurement and precision analysis on alignment of laser and target in ICF[J]. Editorial Office of Optics and Precision Engineering, 2009,17(3): 542-548
LIU Bing-guo, LIU Guo-dong, PU Zhao-bang, ZHUANG Zhi-Tao, CHEN Feng-Dong. Measurement and precision analysis on alignment of laser and target in ICF[J]. Editorial Office of Optics and Precision Engineering, 2009,17(3): 542-548DOI:
Measurement and precision analysis on alignment of laser and target in ICF
To improve the alignment precision of laser beam and target for high power laser driving device in Inertia Confinement Fusion(ICF)
several kinds of laser beam aligning methods
such as inside chamber direct alignment method
outside chamber direct alignment method
and indirect alignment method with Laser and Target Alignment Sensor(LTAS) based on optical conjugate principle
were induced and their advantages and disadvantages were analyzed. Then
the precision of the last method including the image measuring error
the errors introduced by protective glass of CCD
the movement errors of guides and the calibration error of Laser and Target Alignment Sensor(LTAS) was discussed. The experiments and precision analysis indicated that the laser beam aligning precision induced by LTAS is 10 m
which shows proposed LTAS can rapidly and exactly align the laser and target of large-scale laser driving device.
关键词
Keywords
references
BOEGE S J,BLISS E S,CHOCLE C J, et al.. NIF pointing and centering systems and target alignment using 351 nm laser source [J]. SPIE, 1997,3047:248-258.[2] 黄宏一,顾震,范滇元. 神光II装置的靶瞄准系统 . 中国激光, 1998,25(8):711-714. HUANG H Y, GU ZH, FAN D Y. Target collimating system for ShenGuang II Device . Chinese Journal Lasers, 1998,25(8):711-714.(in Chinese)[3] 刘炳国,宫娜,刘国栋,等. ICF靶场坐标系建立及其监测方法[J]. 光学 精密工程,2007,15(7):1070-1076. LIU B G,GONG N,LIU G D, et al.. The study for coordinate system of ICF shooting range and the monitoring instrument [J]. Opt. Precision Eng., 2007,15(7):1070-1076. (in Chinese)[4] 刘国栋,蔡丹,浦昭邦,等. 一种基于差动调焦的激光共轭引导传感器[J]. 光学技术,2005,31(5):746-748. LIU G D, CAI D, PU ZH B, et al.. A laser conjugation directing sensor based on differential focusing [J]. Optical Technique, 2005,31(5):746-748.(in Chinese)[5] 张舞杰,杨义路,李迪,等. 自动影像测量系统关键 算法研究[J]. 光学 精密工程,2006,14(2):294-301. ZHANG W J,YANG Y L,LI DI, et al.. Key algorithms of automatic image measurement system [J]. Opt. Precision Eng., 2006,15(2):294-301.(in Chinese)[6] 高策,乔彦峰. 光电经纬仪实时误差的修正[J]. 光学 精密工程,2007,15(6):846-850. GAO C,QIAO Y F. Real-time error-correction method for photoelectrical theodolite [J]. Opt. Precision Eng.,2007,15(6):846-850. (in Chinese)[7] 刘万里,王占奎,曲兴华,等. 机机载光电跟踪测量设激光跟踪测量系统跟踪转镜的误差分析[J]. 光学 精密工程, 2008,16(4):585-590. LIU W L,WANG ZH K,QU X H, et al.. Error analysis of tracking mirror for laser tracker system [J]. Opt. Precision Eng., 2008,16(4):585-590.(in Chinese)