LabVIEW has the advantage of high efficiency on development
all kinds of functions and so on. But it is not as good as the C language on hardware driving. Take a emulational device for opto-electric detecting in Hyper Spectral Imager for example
In order to resolve the technical difficulties on hardware interrupt in LabVIEW
the interrupt service routine was programmed by C language
the C program was changed to dynamic link library in the visual C++ and the library function node was called in LabVIEW. The control and test on opto-electric devices were achieved by 1553B bus communication. At the same time
a kind of method on improving transmission real time characteristic of 1553B was given in this paper
which bases on improved Rate-Monotonic Scheduling algorithm and K昉earson chi-square. In the condition of transmitting several periodic and aperiodic messages
the experimental results show that the method has good performance on real time characteristic and reliability
Program control in transition observation of strontium optical lattice clock
Multi-dimensional calibration system for laser demarcation instrument
Parameter identification of parallel type six-axis accelerometer
Measurement and Correction for Micro-displacement of Piezoceramic Tube
Mixed programming method based on Windows95
Related Author
ZHANG Shou-gang
CHANG Hong
LU Ben-quan
LIU Hui
REN Jie
XU Xian-ze
CHEN Shao-yang
LE Yi
Related Institution
Key Laboratory of Time and Frequency Primary Standards of Chinese Academy of Sciences, National Time Service Center, Chinese Academy of Sciences, Xi'an 710600, China
University of Chinese Academy of Sciences
School of Electronic Information, Wuhan University
School of Economics and Management, Wuhan University