Run-zhi LU, Fei-peng ZHU, Jin TAO, et al. Long-gauge-length and high-accuracy optical extensometer based on field-of-view splitting[J]. Optics and precision engineering, 2020, 28(11): 2446-2451.
DOI:
Run-zhi LU, Fei-peng ZHU, Jin TAO, et al. Long-gauge-length and high-accuracy optical extensometer based on field-of-view splitting[J]. Optics and precision engineering, 2020, 28(11): 2446-2451. DOI: 10.37188/OPE.20202811.2446.
Long-gauge-length and high-accuracy optical extensometer based on field-of-view splitting
Limited by the resolution of the camera and the effect of rigid-body out-of-plane displacement
the strain measurement accuracy of an optical extensometer based on two-dimensional digital image correlation (2D-DIC) is often not high. To address the problem of insufficient camera resolution
a field-of-view (FOV) splitting device was proposed. The device used a right-angled optical prism and two mirrors to split the camera's continuous FOV into two independent fields separated by a certain distance. This device considerably increased the gauge length of the optical extensometer
thus effectively reducing the strain error caused by insufficient camera resolution. Moreover
a telecentric lens was adopted to reduce the effect of out-of-plane motion on the 2D-DIC extensometer. Static tests and uniaxial tensile tests were conducted to verify the feasibility of the proposed extensometer. Experimental results demonstrate that the root mean square errors of corresponding strain results are all within 6
μ
ε. The proposed optical extensometer based on FOV splitting is a high-accuracy strain measurement technique.
关键词
Keywords
references
X SHAO , M M EISA , Z CHEN , 等 . Self-calibration single-lens 3D video extensometer for high-accuracy and real-time strain measurement . Optics Express , 2016 . 24 ( 26 ): 30124 - 30138 . DOI: 10.1364/OE.24.030124 http://doi.org/10.1364/OE.24.030124 .
C W LU , J YANG . Development of a new differential extensometer . Journal of Geodesy & Geodynamics , 2009 . 2 ( 1 ): 77 - 80 .
M L DAI , X Y XU , F J YANG , 等 . Measurement of continuous deformation of a thin-walled sphere compressed by a rigid plate . Opt. Precision Eng , 2016 . 24 ( 5 ): 993 - 1000 . http://ope.lightpublishing.cn/thesisDetails?columnId=1812340&Fpath=&index=-1&l=zh http://ope.lightpublishing.cn/thesisDetails?columnId=1812340&Fpath=&index=-1&l=zh .
ZH Z TANG , J LIANG , ZH ZH XIAO , 等 . Digital image correlation system for three-dimensional deformation measurement . Opt.Precision Eng , 2010 . 18 ( 10 ): 2244 - 2253 . http://ope.lightpublishing.cn/thesisDetails?columnId=1751278&Fpath=&index=-1&l=zh http://ope.lightpublishing.cn/thesisDetails?columnId=1751278&Fpath=&index=-1&l=zh .
H NGUYEN , H KIEU , Z WANG , 等 . Three-dimensional facial digitization using advanced digital image correlation . Applied Optics , 2018 . 57 ( 9 ): 2188 - 2196 . DOI: 10.1364/AO.57.002188 http://doi.org/10.1364/AO.57.002188 .
M N HELFRICK , C NIEZRECKI , P AVITABILE , 等 . 3D digital image correlation methods for full-field vibration measurement . Mechanical Systems and Signal Processing , 2011 . 25 ( 3 ): 917 - 927 . DOI: 10.1016/j.ymssp.2010.08.013 http://doi.org/10.1016/j.ymssp.2010.08.013 DOI: 10.1016/j.ymssp.2010.08.013 http://doi.org/10.1016/j.ymssp.2010.08.013 .
F GRYTTEN , H DAIYAN , M POLANCO-LORIA , 等 . Use of digital image correlation to measure large-strain tensile properties of ductile thermoplastics . Polymer Testing , 2009 . 28 ( 6 ): 653 - 660 . DOI: 10.1016/j.polymertesting.2009.05.009 http://doi.org/10.1016/j.polymertesting.2009.05.009 .
Y ZHANG , B PAN , G P GUO , 等 . Comparison of measurement precision of strain and Poisson's ratio using contact and non-contact extensometer . Journal of Experimental Mechanics , 2018 . 33 ( 1 ): 59 - 68 . http://www.cnki.com.cn/Article/CJFDTotal-SYLX201801008.htm http://www.cnki.com.cn/Article/CJFDTotal-SYLX201801008.htm .
H CH TANG , D H LI , L LI , 等 . Planar object surface shape speckle pattern deflectometry based on digital image correlation . Acta Optica Sinica , 2019 . 39 ( 2 ): 192 - 198 . http://www.cnki.com.cn/Article/CJFDTotal-GXXB201902023.htm http://www.cnki.com.cn/Article/CJFDTotal-GXXB201902023.htm .
B PAN , H M XIE , Y XIA , 等 . Large-deformation measurement based on reliable initial guess in digital image correlation method . Acta Optica Sinica , 2009 . 29 ( 2 ): 400 - 406 . http://www.cnki.com.cn/Article/CJFDTotal-GXXB200902026.htm http://www.cnki.com.cn/Article/CJFDTotal-GXXB200902026.htm .
Y YANG , Y L WANG , M LI , 等 . Research of high-accuracy digital image correlation measurement system . Acta Optica Sinica , 2006 . 26 ( 2 ): 197 - 201 . http://d.wanfangdata.com.cn/Periodical/gxxb200602008 http://d.wanfangdata.com.cn/Periodical/gxxb200602008 .
M A SUTTON , J H YAN , V TIWARI , 等 . The effect of out-of-plane motion on 2D and 3D digital image correlation measurements . Optics and Lasers in Engineering , 2008 . 46 ( 10 ): 746 - 757 . DOI: 10.1016/j.optlaseng.2008.05.005 http://doi.org/10.1016/j.optlaseng.2008.05.005 .
B PAN , L P YU , D F WU , 等 . High-Accuracy two-dimensional digital image correlation measurement system using a bilateral telecentric lens . Acta Optica Sinica , 2013 . 33 ( 4 ): 105 - 115 .
F P ZHU , Y GONG , P X BAI , 等 . Study on strain measurement accuracy of optical extensometers based on digital image correlation . Opt. Precision Eng , 2018 . 26 ( 5 ): 1061 - 1069 . http://ope.lightpublishing.cn/thesisDetails?columnId=1415217&Fpath=&index=-1&l=zh http://ope.lightpublishing.cn/thesisDetails?columnId=1415217&Fpath=&index=-1&l=zh .