LIN Xu-dong, WANG Jian-li, LIU Xin-yue, YANG Fei, CHEN Tao. Co-phase experiment of active optics for segmented-mirrors[J]. 光学精密工程, 2010,18(7): 1520-1528
LIN Xu-dong, WANG Jian-li, LIU Xin-yue, YANG Fei, CHEN Tao. Co-phase experiment of active optics for segmented-mirrors[J]. 光学精密工程, 2010,18(7): 1520-1528 DOI: 10.3788/OPE.20101807.1520.
Co-phase experiment of active optics for segmented-mirrors
The segmented telescope can realize the diffraction-limited imaging when segmented-mirrors are in co-phase. Therefore
an active optical experiment system was built to measure and adjust the phase difference between the two segmented mirrors. The segmented telescope is consists of three hexagonal segments with the side lengths of 300 mm and the radius of curvature of 2 000 mm. Firstly
a Shack-Hartmann sensor and high accuracy micro-positioning stages were used to make the segments co-focused in a high accuracy. Then
a spherometer was used to piston the phase difference between the two segments to a few micrometer level and the principle of white light Fizeau interferometry was utilized to adjust the phase difference. Finally
the sub-aperture diffraction method was taken to measure the phase difference and to piston the mirror to reduce the phase difference to near zero. To verify the calibration effects
an imaging experiment was carried out for an optical bundle
the experimental results show that the measurement accuracy of white light Fizeau interferometry is better than 100 nm
and that of sub-aperture diffraction method is better than 16 nm
which demonstrates that the methods introduced are suitable for the co-phase calibration of segmented telescopes.
关键词
Keywords
references
GARRY A C,MITCHELL T.Strehl ratio and modulation transfer function for segmented mirror telescopes as functions of segment phase error[J]. Appl. Opt., 1999, 38:6642-6647.
林旭东,陈涛,王建立,等. 拼接镜主动光学共焦试验[J]. 光学 精密工程,2010,18(3):563-569. LIN X D, CHEN T, WANG J L, et al.. Co-Focus experiment of segmented-mirror active optics [J]. Opt. Precision Eng., 2010,18(3): 563-569. (in Chinese)
GARRY A C,MITCHELL T, FRANK D, et al.. Phasing the mirror segments of the W. M. Keck Telescope: the broadband phasing algorithm
. Appl. Opt., 1998,37(1) :140-155.
GARRY A C, OHARA G, TROY M. Phasing the mirror segments of the Keck telescopes II: the narrow-band phasing algorithm [J]. App. Opt., 2000,39:4706-4714.
ORLOV V G, CUEVAS S, GARFIAS F, et al.. Co-phasing of segmented mirror telescopes with curvature sensing [J]. SPIE, 000,4004:540-551.
HORTON R F,HUBBER E E,BERNOTAS L A, et al.. Absolute piston phasing of segmented-mirror optical systems using depth-modulated white-light interferometry [J].SPIE,1990,1236:974-984.
DOHLEN K,DECORTIAT F,FRESNEAU F, et al.. Dual wavelength random-phase-shift interferometer for phasing large segmented primaries[J]. SPIE,1998,3352:551-559.
PAXMAN R G,FIENUP J R. Optical misalignment sensing and image reconstruction using phase diversity[J]. Opt. Soc.Am,1988,A5:914922.
LOFDAHL M G,KENDRICK R L,HARWIT A,A phase diversity experiment to measure piston misalignment on the segmented primary mirror of the Keck II telescope[J]. SPIE, 1998,3356:1190-1201.
ESPOSITO S, PINNA E, TOZZI A, et, al.. Co-phasing of segmented mirrors using the pyramid sensor [J]. SPIE, 2003,5169:72-78.
林旭东,陈涛,王建立,等. 球面拼接镜相对曲率半径测量[J]. 光学 精密工程,2010,(4):191-197. LIN X D, CHEN T, WANG J L, et al.. Relative radius of curvature metrology for spherical segmented mirrors[J]. Opt. Precision Eng., 2010,(4):191-197. (in Chinese)
ZOU W Y, New phasing algorithm for large segmented telescope mirrors[J]. Opt. Eng.,2002, 41(9): 2338-2344.
WANG S Q,RAO CH H,JIANG W H, et al.. High-resolution imaging techniques based on Optical Synthetic Aperture[J]. PIE ,2007,6721:03-1-03-8.
GARRY A C, TERRY S M, JERRY E N, Phasing the mirror segments of the W. M. Keck Telescope[J]. SPIE, 1994,2199: 622-637.