HU Xiu-qing, ZHANG Li-yang, ZHENG Zhao-jun, ZHANG Yong, SUN Ling, DING Lei, HUANG Xiao-xian. FY-3A multi-detector radiometric calibration for infrared band of medium resolution spectral imager[J]. 光学精密工程, 2010,18(9): 1972-1980
As the FY-3A Medium Resolution Spectral Imager(MERSI) takes a cross-track scanning by 40 detectors in a thermal Infrared Window band
its radiometric calibration is more complicate than those of traditional single detectors. Therefore
this paper investigates a multi-detector radiometric calibration method for the MERSI. Firstly
the operational calibration algorithm for the IR band of MERSI based on onboard blackbody detector-by-detector is proposed to eliminate the radiometric response difference strips.Then
based on the radiance ratios of each detector to reference detector at different blackbody temperatures
this algorithm conducts the normalization processing for SRF-different bias (spectral normalization)to alleviate the image strips by radiometric mechanism. To verify the accuracy of MERSI calibration
the inter-calibration between MERSI and Moderate-resolution Imaging Spectroradiometer(MODIS) is performed by using Simultaneous Nadir Observation (SNO).Experiments show that the difference of their brightness temperatures is about 1.0 K
which may come from their different bandwidths.
关键词
Keywords
references
杨军,董超华,卢乃锰,等. 中国新一代极轨气象卫星风云三号
. 气象学报,2009,67(4),501-509. YANG J, DONG CH H, LU N M, et al.. FY-3A: The new generation polar-orbiting meteorological satellite of china
丁雷. FY-3卫星中分辨率光谱成像仪正样设计报告 . 上海:中国科学院上海技术物理研究所,2005. DING L. Flight Model Design of FY-3A MEdium Resolution Spectral Imager (MERSI) . Shanghai: Shanghai Institute of Technical Physics of Chinese Academy of Sciences,2005.(in Chinese)
丁雷. FY-3卫星中分辨率光谱成像仪正样(Z01-2)研制总结报告 . 上海:中国科学院上海技术物理研究所,2007. DING L. Flight Model (Z01-2) Development Review of FY-3A MEdium Resolution Spectral Imager (MERSI) . Shanghai: Shanghai Institute of Technical Physics of Chinese Academy of Sciences,2007.(in Chinese)
GUENTHER B W. KNIGHT B S. MODIS calibration: A brief review of the strategy for the at-Launch calibration approach
. J. Atmos. Ocean. Tech., 1996,13,274-285.
XIONG J,TOLLER G,CHIANG V, et al.. MODIS level 1B Algorithm Theoretical Basis Document, MODIS Characterization Support Team
. 2005.
GUENTHER B,GODDEN G D,XIONG X, et al.. Pre-launch algorithm and data format for the Level 1 calibration products for the EOS AM-1 Moderate Resolution Imaging Spectroradiometer (MODIS)