CHEN Hong-yao, ZHANG Li-ming. Spectral calibration for dispersive hyperspectral sensor based on doped reflectance standard panel[J]. Editorial Office of Optics and Precision Engineering, 2010,18(12): 2642-2649
CHEN Hong-yao, ZHANG Li-ming. Spectral calibration for dispersive hyperspectral sensor based on doped reflectance standard panel[J]. Editorial Office of Optics and Precision Engineering, 2010,18(12): 2642-2649 DOI: 10.3788/OPE.20101812.2642.
Spectral calibration for dispersive hyperspectral sensor based on doped reflectance standard panel
Spectral calibration is a key to realize the quantification of hyperspectral remote sensing. Traditionally
the spectral calibration for a hyperspectral sensor is performed by a monochromator scanning method with disadvantages of expensive
time-consuming
etc
.
which is difficult to achieve the real-time and high-accuracy spectral calibration in the field or in-flight.In this paper
an accuracy and fast system level spectral calibration method was described for determining the center wavelengths for every spectral channel simultaneously. The reflective signals of a diffuse reflectance standard panel and a diffuse reflectance standard panel doped with a rare earth oxide were measured by the hyperspectral sensor. The ratio of two signals was optimized to remove the effects of sensor spectral response and lamp spectral output. By assuming a certain parametric model of the sensor and performing a nonlinear least squares fit of the measured ratio to the expected ratio
the center wavelength and bandwidth could be derived. A field spectroradiometer
FieldSpec UV/VNIR
was calibrated by proposed method
and the factors that effect on the calibration accuracy were analyzed. The results show that the wavelength accuracy is less than 0.5 nm
which indicates that the technology can meet the urgent needs of high accuracy and fast spectral calibration of hyperspectral sensors.
关键词
Keywords
references
束炯, 王强, 孙娟. 高光谱遥感的应用研究[J]. 华东师范大学学报(自然科学版), 2006(4):1-10. SHU J, WANG Q, SUN J. Applications of hyperspectral remote sensing [J]. Journal of East China Normal University(Natural Science),2006(4):1-10. (in Chinese)[2] ROBERT O G. Spectral calibration requirement for Earth-looking imaging spectrometers in the solar-reflected spectrum[J]. Appl. Opt.,1998,37:683-690.[3] 徐中民,禹秉熙. 对PC2000-PC/104型光谱仪的波长定标[J]. 光学 精密工程, 2004, 12(1):11-14. XU ZH M,YU B X. Wavelength calibration for PC2000-PC/1 04 spectrometer[J]. Optics and Precision Engineering, 2004,12(1):11-14. (in Chinese)[4] LUIS G, RUDOLF R, JOS M. Spectral calibration of hyperspectral imagery using atmospheric absorption features[J]. Appl. Opt., 2006,45:2360-2370.[5] GAO B C, MONTES M J, DAVIS C O. Refinement of wavelength calibrations of hyperspectral imaging data using a spectrum-matching technique[J]. Remote Sens. Environ., 2004,90:424-433.[6] LUIS G, KARL S, BERNHARD S,et al.. Scene-based spectral calibration assessment of high spectral resolution imaging spectrometers[J]. Opt. Express, 2009,17:11594-11606.[7] PAMELA B, JOHN S, CAROL S. Hyperion on-orbit validation of spectral calibration using atmospheric lines and an on-board system[J]. SPIE, 2002,4480:231-235.[8] HEDMAN T R, JARECKE P J, LIAO L B. Hyperspectral imaging spectrometer spectral calibration . United State: 6,111,640.2000-08-29.[9] 王先华,张黎明,乔延利. 光谱辐射计波长定标新方法的研究[J]. 量子电子学报,1999,16(5):442-447. WANG X H, ZHANG L M, QIAO Y L. Study of new wavelength calibration way for spectrometer[J]. Chinese Journal of Quantum Electronics,1999,16(5):442-447. (in Chinese)[10] JUNGHWAN C, PAUL J, GEMPERLINE, et al.. Wavelength calibration method for a CCD detector and multichannel fiber-optic probes[J].Appl. Spectrosc, 1995,49:1841-1845.[11] 杨本永,张黎明,沈政国,等. 光学传感器星上定标漫射板的特性测量[J]. 光学 精密工程, 2009,17(8):1851-1858. YANG B Y,ZHANG L M,SHEN ZH G, et al.. Characteristic measurement of diffuser panel used for on-board calibration for satellite optical sensors[J]. Opt. Precision Eng., 2009,17,8:1851-1858 (in Chinese)[12] JACK J H, VICTOR R W. NBS 45/normal reflectometer for absolute reflectance factors[J].Metrologia,1981(17):97-102.[13] JOHN H L. Diffuse light correction for field reflectance measurements . Tucson:University of Arizona,2002.
Wavelength calibration of absolute irradiance spectra-radiometer
Semi-supervised dual path network for hyperspectral image classification
Deep manifold reconstruction belief network for hyperspectral remote sensing image classification
Spectral calibration of Fengyun-3 satellite high-spectral resolution infrared sounder
Multi-features manifold discriminant embedding for hyperspectral image classification
Related Author
LIU En-chao
ZHENG Xiao-bing
LI Xin
ZHANG Yan-na
Zhengying LI
Ling JI
Zhen ZHANG
Hong HUANG
Related Institution
Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences2. Optics and Fine Mechanics, Chinese Academy of Sciences
The 34th Research Institute of China Electronics Technology Group Corporation
Key Laboratory of Optoelectronic Technology and System, Ministry of Education, Chongqing University
Key Laboratory of Radiometric Calibration and Validation for Environmental Satellites, China Meteorological Administration, National Satellite Meteorology Center