LIU Yong, YANG Zhi-gang, WU Yue LIU Lei, DONG Jing-shi. Analysis on sucking process outflow phenomenon of piezoelectric pump[J]. Editorial Office of Optics and Precision Engineering, 2011,19(5): 1104-1109
LIU Yong, YANG Zhi-gang, WU Yue LIU Lei, DONG Jing-shi. Analysis on sucking process outflow phenomenon of piezoelectric pump[J]. Editorial Office of Optics and Precision Engineering, 2011,19(5): 1104-1109 DOI: 10.3788/OPE.20111905.1104.
Analysis on sucking process outflow phenomenon of piezoelectric pump
The sucking outflow phenomena of a passive piezoelectric pump under the square wave driving is studied and a hydrodynamics model and a vibration model of the passive piezoelectric pump are built to analyze theoretically the physical process of the sucking outflow process.Then
an open height formula of the exiting valve in sucking processing is derived. The open height of the piezoelectric pump is measured during the sucking outflow process under different frequencies of 0.4
0.8
6
45 Hz
and the other factors effecting on the sucking outflow in the formula are verified. In the theoretical analysis
it points out that the flow inertia is the root cause for the outflow sucking phenomena
and the inertial flow also exists during the draining process. The experiment indicates that when the piezoelectric frequency increases
the open height of the exiting valve during sucking process decreases. When the exiting valve rigidity and the loadings in input and output increase
the outflow decreases.The results above are coincident with the formula well. It concludes that the output flow of the piezoelectric pump should include two parts: cubage flow and inertial flow
which should be considered in the same time when the flow of the piezoelectric pump is controlled precisely.
关键词
Keywords
references
杨树臣,程光明,刘国君,等. 微型压电泵系统的设计研究 [J]. 光学 精密工程, 2005, 13(3):318-323. YANG SH CH, CHENG G M, LIU G J, et al.. Design of piezoelectric micro-pump[J]. Opt. Precision Eng., 2005,13(3):318-323. (in Chinese)[2] 杨志刚,孙晓锋,张德君,等. 双腔串联两阀与三阀压电泵的性能研究 [J]. 光学 精密工程, 2007,15(2):219-223. YANG ZH G, SUN X F, ZHANG D J, et al.. Performance research on double-valved and three-valved piezoelectric pumps with double series-wound chambers[J]. Opt. Precision Eng., 2007,15(2):219-223. (in Chinese)[3] 张建辉,黎毅力,夏齐霄,等. "Y"形流管无阀压电泵振动分析及泵流量计算[J]. 光学 精密工程, 2007,15(6):922-929. ZHANG J H, LI Y L, XIA Q X, et al.. Research on the vibration and pump flow rate of valveless piezoelectric pump with Y-shape tubes [J]. Opt. Precision Eng., 2007,15(6):922-929. (in Chinese)[4] 刘国君,程光明,杨志刚. 一种压电式精密输液微泵的试验研究[J]. 光学 精密工程,2006,14(4):612-616. LIU G J, CHENG G M, YANG ZH G. Experimental research on a piezoelectric micro-pump for precision pumping[J]. Opt. Precision Eng., 2006,14(4):612-616. (in Chinese)[5] YE F, LI Y L, ZHANG J H. Dynamic research on actuator for valveless piezoelectric pump with Y-shape tubes [J]. Opt. Precision Eng., 2008,16(12):2358-2365.[6] 阚君武, 杨志刚, 唐可洪. 新结构药品输送压电泵的泵送特性[J]. 生物医学工程学杂志,2004,21(2):297-301. KAN J W, YANG ZH G, TANG K H. Pumping performance of a new piezoelectric pump for drug delivery [J]. Journal of Biomedical Engineering, 2004,21(2):297-301. (in Chinese)[7] E.约翰芬纳莫尔,约瑟夫B.弗朗兹尼. 流体力学及其工程应用[M]. 北京:机械工业出版社,2005. JOHN FINNEMORE E,JOSEPH FRANZINI B. Fluid Mechanics with Engineering Applications [M]. Beijing:China Machine Press,2005. (in Chinese)[8] LIA B,CHEN Q F, LEE D G,et al.. Development of large flow rate, robust, passive micro check valves for compact piezoelectrically actuated pumps[J]. Sensors and Actuators A, 2005,117(2):325-330.[9] SATYAJIT K, SCOTT M, SEAN M,et al..Piezoelectric mechanical pump with nanoliter per minute pulse-free flow delivery for pressure pumping in pulse-free flow delivery for pressure pumping in micro-channels[J]. Analyst, 1998,123(6):1435-1441.[10] 吴丽萍,程光明,杨志刚,等. 双作用压电泵绝缘压电振子的研究[J]. 光学 精密工程, 2008, 16(1):103-107. WU L P, CHENG G M, YANG ZH G,et al.. Research on insulated bimorph in piezoelectric pump with double functions[J].Opt. Precision Eng., 2008,16(1):103-107.