GONG Dun, TIAN Tie-yin, WANG Hong. Thermal optical analysis of off-axis three-mirror system and its thermal control requirements[J]. Editorial Office of Optics and Precision Engineering, 2011,19(6): 1213-1220
GONG Dun, TIAN Tie-yin, WANG Hong. Thermal optical analysis of off-axis three-mirror system and its thermal control requirements[J]. Editorial Office of Optics and Precision Engineering, 2011,19(6): 1213-1220 DOI: 10.3788/OPE.20111906.1213.
Thermal optical analysis of off-axis three-mirror system and its thermal control requirements
temperature is the key factor influencing the optical system imaging quality. To investigate the effect of temperature on the off-axis three mirror system
a thermal optical analysis method from finite element analysis to optical analysis was presented.On the basis of analysis results of the optical system in uniformly distributed temperature fileds
the surface aberration of mirrors with temperature gradients was obtained by using a finite element analysis software
and the surfaces with aberration were fitted with the Zernike Polynomials. Then
the Zernike coefficients were carried into the software CODE V
the imaging qualities of the system with difference temperature gradients were analyzed
and thermal control requirements were determined. Finally
a thermal optical experiment was carried out to test the optical system with active thermal controls. Experimental results show that the MTF of full field in the optical system is more than 0.2 in 56 lp/mm
which means the optical parameters meet the the requirements of optical system.Results also verify the correctness of the theory and the reasonabity of thermal control requirements.
关键词
Keywords
references
常军,翁志成,姜会林,等. 长焦距空间三反光学系统的设计[J]. 光学 精密工程,2001,9(4):315-318. CHANG J, WENG ZH C, JIANG H L, et al.. Design of long focal length space optical system with three reflective mirror[J]. Opt. Precision Eng., 2001, 9(4):315-318.(in Chinese)[2] 常军,翁志成,姜会林,等. 宽覆盖、离轴空间相机光学系统的设计[J]. 光学 精密工程,2003,11(1):55-58. CHANG J, WENG ZH C, JIANG H L, et al.. Design of optical system for space camera with long focal length, wide coverage and high resolution[J]. Opt. Precision Eng., 2003, 11(1):55-58.(in Chinese)[3] 张亮,安源,金光. 大视场、长焦距离轴三反射镜光学系统的设计[J]. 红外与激光工程,2007,36(2):278-280. ZHANG L, AN Y, JIN G. Optical design of the uncoaxial three-mirror system with wide field of view and long focal length[J]. Infrared and Laser Engineering, 2007, 36(2):278-280. (in Chinese)[4] 吴清文,卢泽生,卢锷,等. 空间光学遥感器热分析[J]. 光学 精密工程,2002,10(2):205-208. WU Q W, LU Z S, LU E, et al.. Thermal analysis far a space optical remote sensor[J]. Opt. Precision Eng., 2002,10(2):205-208.(in Chinese)[5] 杨怿,张伟,陈时锦. 基于集成分析法的光机热一体化设计[J]. 光学技术,2005,31(3):394-397. YANG Y, ZHANG W, CHEN S J. Thermal/structural/optical concurrent design based on integrated analysis technique[J]. Optical Technique, 2005,31(3):394-397.(in Chinese)[6] 郭永洪,沈忙作,陆祖康. 离轴三反射镜系统研究[J]. 光电工程,1999,26:45-48. GUO Y H, SHEN M Z, LU Z K. A study on off-axis thee-mirror system[J]. Opto-Electronic Engineering, 1999,26:45-48. (in Chinese)[7] 张以谟.应用光学[M]. 北京:机械工业出版社,1987:375-378. ZHANG Y M. Applied Optics[M]. Bejing: Machine and Industry Publishing Company,1987:375-378.[8] 霍尔曼 J.P.传热学[M]. 北京:人民教育出版社,2005:38-39. HOLMAN J P. Heat Transfer[M]. Bejing: People Education Publishing Company,2005:38-39.[9] 巩盾,王红,田铁印. 温度对星载三线阵相机成像质量的影响与温控指标的制定[J]. 光学学报,2010,30(8):85-90. GONG D, WANG H, TIAN T Y. Temperature effect on imaging performance of three-line CCD satellite camera and temperature indicators affirmed[J]. Acta Optica Sinica, 2010,30(8):85-90. (in Chinese)[10] 王淑岩,单宝忠,牛憨笨. Zernike多项式拟合方法及应用[J]. 光学 精密工程,2002,10(3):318-323. WANG SH Y,SHAN B Z, NIU H B, Zernike polynomial fitting method and its application[J]. Opt. Precision Eng., 2002,10(3):318-323. (in Chinese)