XUE Xiang-yao, GAO Yun-guo, HAN Guang-yu, SHAO Shuai, QIAO Jian. Total correction method of pointing error for level mounting theodolite[J]. Editorial Office of Optics and Precision Engineering, 2011,19(7): 1524-1530
A total pointing error correction model was built to correct the pointing errors of a level mounting theodolite. Based on the opto-mechanical structure of the level mounting theodolite
a geodetic coordinate system and a pointing coordinate system were built. Then
according to the location relationship between the two coordinate systems
the target coordinate in the geodetic coordinate system was expressed. After a total differential for the target coordinate
an equation was obtained to describe the relation between target coordinate error and longitude & latitude errors of the level mounting theodolite. By considering the three shafting errors to be the major ones of the system
5 linear coordinate transformations were performed to deduce a total coordinate error equation for three shafting errors.Combined with the total differential equation
a unitive compensation model of pointing error on the three shafting errors was obtained. By linear superposition with the pointing error caused by encoder errors
the total pointing error of the level mounting theodolite was gained. Finally
46 stars scattered in sky space uniformly were selected to be measured
and the discrete values of the 46 stars pointing errors were gained in longitude and latitude dimensions
respectively. After least square fitting
the undetermined coefficients in the total pointing error model were obtained. Experimental results indicate that the total pointing accuracy can rise from 40.1 to 3.4 after correction
which meets the accuracy request in a general design.
关键词
Keywords
references
平一鼎,张晓祥,鲁春林. 65 cm水平式望远镜静态指向模型[J]. 天文学报,2006,47(2):224-230. PING Y D, ZHANG X X, LU CH L. Static pointing model of 65 cm level mounting telescope[J]. Acta Astronomica Sinica, 2006,47(2):224-230.(in Chinese)[2] 赵金宇,王德兴,李文军,等. 望远镜系统误差动态修正的一种新方法[J]. 红外与激光工程,2005,34(2):244-247. ZHAO J Y, WANG D X, LI W J, et al. New method of dynamic correction for the system errors of telescope[J]. Infrared and Laser Engineering, 2005,34(2):244-247. (in Chinese)[3] 王家骐,金光,颜昌翔. 机载光电跟踪测量设备的目标定位误差分析[J]. 光学 精密工程,2005,13(2):105-108. WANG J Q, JIN G, YAN CH X. Orientation error analysis of airborne opto-electric tracking and measuring device [J]. Opt. Precision Eng., 2005,13(2):105-108. (in Chinese)[4] 王晶,高利民,姚俊峰. 机载测量平台中的坐标变换误差分析[J]. 光学 精密工程,2009,17(2):389-392. WANG J, GAO L M, YAO J F. Analysis on coordinate conversion error of airborne measuring device[J]. Opt. Precision Eng., 2009,17(2):389-392.(in Chinese)[5] 明名,王建立,张景旭,等. 大口径望远镜光学系统的误差分配与分析[J]. 光学 精密工程,2009,17(1):104-107. MING M, WANG J L, ZHANG J X, et al. Error budget and analysis for optical system in large telescope[J]. Opt. Precision Eng., 2009,17(1):104-107.(in Chinese)[6] 陆震.高等机械原理[M]. 北京:北京航空航天大学出版社,2001. LU ZH. Senior Mechanical Theory[M]. Beijing: Publishing House of BUAA, 2001. (in Chinese)[7] 张晓祥,吴连大. 望远镜静态指向模型的基本参数[J]. 天文学报,2001,42(2):199-200. ZHANG X X, WU L D. The basic parameters of telescope static point model[J]. Acta Astronomica Sinica, 2001,42(2):199-200.(in Chinese)[8] 张世箕.测量误差及数据处理[M]. 北京:科学出版社,1979. ZHANG SH J. Measurement Deviation and Data Analysis[M]. Beijing: Science Press, 1979. (in Chinese)[9] 巩岩.利用恒星标校卫星激光测距经纬仪指向精度[J]. 光学 精密工程,2000,8(3):259-260. GONG Y. Calibrating the pointing precision of satellite laser ranging theodolite by observing stars[J]. Opt. Precision Eng., 2000,8(3):259-260.(in Chinese)