HU Hao, LIANG Jin, TANG Zheng-zong, SHI Bao-quan, GUO Xiang. Global calibration for muti-camera videogrammetric system with large-scale field-of-view[J]. Editorial Office of Optics and Precision Engineering, 2012,20(2): 369-378
HU Hao, LIANG Jin, TANG Zheng-zong, SHI Bao-quan, GUO Xiang. Global calibration for muti-camera videogrammetric system with large-scale field-of-view[J]. Editorial Office of Optics and Precision Engineering, 2012,20(2): 369-378 DOI: 10.3788/OPE.20122002.0369.
Global calibration for muti-camera videogrammetric system with large-scale field-of-view
An accurate global calibration method for a muti-camera videogrammetric system with large field-of-view is presented. Firstly
a cross target with feature points pasted on its two sides is designed as the calibration reference pattern
and the world coordinates of these feature points are reconstructed using the XJTUDP photogrammetric system. Then
the calibration target is placed in the public field-of-view and its images shown at different orientations are captured by the four cameras simultaneously. Finally
based on a 10-parameter nonlinear camera model
the capatured images are calibrated successively and the camera interior parameters and global orientation parameters with respect to a predefined global coordinate system are obtained. Experimental result indicates that the proposed calibration method can offer a considerable accuracy in a re-projection error less than 0.05 pixel.By the proposed method
the four-camera videogrammetric system can achieve a relative accuracy of 1/4 000 on length measurement. It can satisfy the demands of the multi-camera videogrammetric measurement with large field-of-view for precision and efficiency.
关键词
Keywords
references
BURNER A, LIU T. Videogrammetric model deformation measurement technique[J]. Journal of Aircraft, 2001, 38(4):745-754.[2] CHANG C, JI Y. Flexible videogrammetric technique for three-dimensional structural vibration measurement[J]. Journal of Engineering Mechanics, 2007,133(6):656-664.[3] WOODHOUSE N, ROBSON S, EYRE J. Vision metrology and three dimensional visualization in structural testing and monitoring[J]. The Photogrammetric Record, 1999, 16(94):625-641.[4] LIU T, CATTAFESTA L, RADEZTSKY R, et al.. Photogrammetry applied to wind-tunnel testing[J]. AIAA Journal, 2000, 38(6):964-971.[5] WALLACE ID, LAWSON NJ, HARVEY AR, et al.. High-speed photogrammetry system for measuring the kinematics of insect wings[J]. Applied Optics, 2006, 45(17):4165-4173.[6] JIANG R, JAUREGUI D. A novel network control method for photogrammetric bridge measurement[J]. Experimental Techniques, 2007, 31(3):48-53.[7] 刘建伟,梁晋,梁新合,等. 大尺寸工业视觉测量系统[J]. 光学 精密工程, 2010,18(1):126-134. LIU J W, LIANG J, LIANG X H, et al.. Industrial vision measuring system for large dimension work-pieces[J]. Opt. Precision Eng., 2010,18(1):126-134. (in Chinese)[8] TSAI R. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses[J]. IEEE Journal of Robotics and Automation, 1987,3(4):323-344.[9] WENG J, COHEN P, HERNIOU M. Camera calibration with distortion models and accuracy evaluation[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1992,14(10):965-980.[10] HEIKKILA J, SILVEN O. A four-step camera calibration procedure with implicit image correction . 1997 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'97),Washington, DC, USA:IEEE, 1997:1106-1112.[11] ZHANG Z. Flexible camera calibration by viewing a plane from unknown orientations . Proceedings of the Seventh IEEE International Conference on Computer Vision, Corfu, Greece:IEEE, 1999:666-673.[12] ZHANG Z. A flexible new technique for camera calibration[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000,22(11):1330-1334.[13] 陈刚, 车仁生, 叶东, 等. 一种基于立体模板的双目视觉传感器现场标定方法[J]. 光学 精密工程, 2004, 12(6):626-631. CHEN G, CHE R SH, YE D, et al.. Stereo vision sensor field calibration method based on volume template[J]. Opt. Precision Eng., 2004,12(6):626-631. (in Chinese)[14] 孙军华, 吴子彦, 刘谦哲,等. 大视场双目立体视觉传感器的现场标定[J]. 光学 精密工程, 2009, 17(3):633-640. SUN J H, WU Z Y, LIU Q ZH, et al.. Field calibration of stereo vision sensor with large FOV[J]. Opt. Precision Eng., 2009,17(3):633-640. (in Chinese)[15] FAUGERAS O, LUONG Q, MAYBANK S. Camera self-calibration: Theory and experiments . European Conference on Computer Vision, Florence, Italy, 1992:321-334.[16] SANSONI G, CAROCCI M, RODELLA R. Calibration and performance evaluation of a 3-D imaging sensor based on the projection of structured light[J]. IEEE Transactions on Instrumentation and Measurement, 2000,49(3):628-636.[17] LUHMANN S R T, KYLE S, HARLEY I. Close Range Photogrammetry: Principles, Techniques and Applications[M]. London:Whittles Publishing, 2006.[18] CANNY J F. A computational approach to edge detection[J]. IEEE Trans. Pattern Anal. Mach. Intell, 1986, 8(6):679-714.[19] MAI F, HUNG Y S, ZHONG H, et al.. A hierarchical approach for fast and robust ellipse extraction[J]. Pattern Recogn, 2008, 41(8):2512-2524.[20] ZHANG D H, LIANG J,GUO C, et al.. Exploitation of photogrammetry measurement system[J]. Optical Engineering, 2010,49(3):037005-1-11.