ZHANG Lei, YANG Yong, ZHAO Xing, FANG Zhi-liang, YUAN Xiao-cong. Enhancement of field depth for projection-type integral imaging three-dimensional display based on small diverging angle[J]. Editorial Office of Optics and Precision Engineering, 2012,20(6): 1159-1165
ZHANG Lei, YANG Yong, ZHAO Xing, FANG Zhi-liang, YUAN Xiao-cong. Enhancement of field depth for projection-type integral imaging three-dimensional display based on small diverging angle[J]. Editorial Office of Optics and Precision Engineering, 2012,20(6): 1159-1165 DOI: 10.3788/OPE.20122006.1159.
Enhancement of field depth for projection-type integral imaging three-dimensional display based on small diverging angle
As the integral imaging three-dimensional(3D) display technology is limited by the depth of field in a reconstructed image
it can not be widely used in the fields of 3D display. Therefore
this paper proposes a method to enhance the depth of field in a projection-type integral imaging system based on the angle control. To enhance the depth of field
an additional lens is used to control the diverging angle of every pixel in the elemental image array. Contrast to the conventional method with multi-layers
the proposed method has advantages in simpler systems
higher efficiency and lower requests for display devices. Experimental results show that the depth of field is 6.4 times that of original one when the diverging angle is 1.79?. And as compared to the conventional method with an enhancement of 4 times depth of field
the proposed method has increased by 60% in efficiency. These results demonstrate that the proposed method gives a new way to enhance the image quality for integral imaging display systems.
关键词
Keywords
references
LIPPMANN G. La photograhie integrale[J].Comptes Rendus Acad. Sci.,1908,146:446-451.
王涛, 于瀛洁, 郑华东. 彩色全息光电再现倍率色差消除[J]. 光学 精密工程, 2011,19 (6):1414-1420. WANG T, YU Y J, ZHEN H D. Removal of magnification chromatism in optoelectronic full color holography [J]. Opt. Precision Eng., 2011,19(6):1414-1420. (in Chinese)
于瀛洁,倪萍,周文静. 基于全息图放大的数字全息显微结构测量[J]. 光学 精密工程,2008,16(5):827-831. YU Y J, NI P, ZHOU W J. Micro-structure measurement of phase object by digital microholography based on magnified hologram[J]. Opt. Precision Eng.,2008,16(5):827-831. (in Chinese)
姜伟, 魏世衡. 反射型立体视觉系统的视差估计和图像复原[J]. 光学 精密工程,2011,19(7):1702-1707. JIANG W, WEI SH H. Display estimation and image restoration for reflection stereo vision [J]. Opt. Precision Eng., 2011,19(7):1702-1707. (in Chinese)
孙军华, 吴子彦, 刘谦哲, 等. 大视场双目视觉传感器的现场标定 [J]. 光学 精密工程, 2009,17(3):633-640. SUN J H, WU Z Y, LIU Q ZH, et al.. Field calibration of stereo vision sensor with large FOV [J]. Opt. Precision Eng., 2009,17(3):633-640. (in Chinese)
王爱红, 王琼华, 李大海, 等. 立体显示中立体深度与视差图获取的关系 [J]. 光学 精密工程, 2009,38(1):433-438. WANG A H, WANG Q H, LI D H, et al.. Relationship between stereo depth and parallax image captured in stereoscopic display [J]. Opt. Precision Eng., 2009,38(1):433-438. (in Chinese)
王爱红, 王琼华, 李大海, 等. 会聚式相机获取的视差图像的梯形失真校正 [J]. 四川大学学报(工程科学版), 2011,43(2):72-75. ANG A H, WANG Q H, LI D H, et al.. Keystone distortion rectification of parallax images captured by toed-in cameras [J]. Journal of Sichuan University(Engineering Science Edition),2011,43(2):72-75. (in Chinese)
王琼华. 3D显示技术与器件 [M]. 北京:科学出版社,2011. WANG Q H.3D Display Technology and Device[M]. Beijing:Science Press,2011.(in Chinese)
焦小雪, 赵星, 杨勇, 等. 基于最佳记录距离的三维集成成像光学获取技术[J]. 光学 精密工程, 2011,19(11):2805-2811. JIAO X X, ZHAO X, YANG Y, et al.. Optical acquiring technique of three-dimensional integral imaging based on optimal pick-up distance [J]. Opt. Precision Eng., 2011,19(11):2805-2811. (in Chinese)
PARK S G,SONG B S,MIN S W.Analysis of image visibility in projection-type integral imaging system without diffuser[J].J. Opt. Soc. Kor., 2010,14:121-126.
KIM Y,PARK S G,MIN S W,et al..Projection-type integral imaging system using multiple elemental image layers[J].Appl. Opt.,2011,50:B18-B24.
JANG J S,JAVIDI B.Large depth-of-focus time-multiplexed three-dimensional integral imaging by use of lenslets with nonuniform focal lengths and aperture size[J]. Opt. Lett.,2003,28:1924-1926.
HONG J,PARK J H, JUNG S,et al..Depth-enhanced integral imaging by use of optical path control[J].Opt. Lett.,2004,29:1790-1792.
KIM Y,PARK J H,CHOI H,et al..Depth-enhanced three-dimensional integral imaging by use of multilayered display devices[J].Appl. Opt.,2006,45:4334-4343.
KIM Y,CHOI H, KIM J,et al..Depth-enhanced integral imaging display system with electrically variable image planes using polymer-dispersed liquid-crystal layers[J].Appl. Opt.,2007,46:3766-3773.