XIU Ji-hong, HUANG Pu, LI Jun, LI You-yi. Radiometric calibration of large area array color CCD aerial mapping camera[J]. Editorial Office of Optics and Precision Engineering, 2012,20(6): 1365-1373
XIU Ji-hong, HUANG Pu, LI Jun, LI You-yi. Radiometric calibration of large area array color CCD aerial mapping camera[J]. Editorial Office of Optics and Precision Engineering, 2012,20(6): 1365-1373 DOI: 10.3788/OPE.20122006.1365.
Radiometric calibration of large area array color CCD aerial mapping camera
Several kinds of factors affecting the radiometric calibration of a large area array color CCD aerial mapping camera were presented through analyzing the process of camera imaging. Then
a model for radiometric calibration was established. The experiments of radiometric calibration were performed by using integrating sphere and in the dark field
respectively
and outputs of radiometric response of the camera were measured and analyzed through combination of changing the input radiance
exposure time
CCD gain and other factors. The experimental results show that the characteristics of radiometric response for
R
G
and
B
color channels are different when the input radiance is changed
but it varies linearly in the working spectral range. When the least square method is used to fit the calibration data of radiation
the goodness of fit for first-order polynomial shows that the
R
2
is above 0.999. Furthermore
when input radiometric luminance is constant
the output of the camera varies linearly with the exposure time or CCD gain
which lays the theoretical basis for the deduction of radiation response characteristic curves under the other work conditions. The data from radiometric calibration is applied to the exposure parameters
and experimental results indicate that the lightness of image is appropriate and its average gray value satisfies the requirement for exposure.
关键词
Keywords
references
郭悦,刘晓鹏,杨桦. 空间CCD相机的定标方法研究[J]. 光学技术,2007,33(11):237-238. GUO Y,LIU X P,YANG H.Analysis of calibration for space CCD camera[J].Optical Technique,2007,33(11):237-238.(in Chinese)
刘亚侠. TDI CCD相机实验室辐射定标的研究[J]. 光电工程,2007,34(5):71-74. LIU Y X.Research on the laboratory radiometric calibration of the TDI CCD camera[J].Opto-Electronic Engineering,2007,34(5):71-74.(in Chinese)
任焕焕,阮萍,何建伟,等. TDI CCD 空间立体相机辐射定标研究[J]. 光学学报,2010,30(12):3476-3480. REN H H,RUAN P,HE J W.Study of the radiation calibration of TDI CCD spatial stereo camera[J].Acta Optica Sinica,2010,30(12):3476-3480.(in Chinese)
王文华,何斌,韩双丽,等. 星上CCD 成像非均匀性的实时校正[J]. 光学 精密工程,2010,18(6):1420-1428. WANG W H,HE B,HAN S L.Real time correction of nonuniformity in CCD imaging for remote sensing [J].Opt.Precision Eng.,2010,18(6):1420-1428.(in Chinese)
吴波,符泰然,程晓舫,等. 彩色数码相机光强响应特性的标定实验[J]. 光电工程,2006,33(6):101-105. WU B, FU T R, CHENG X F,et al.. Calibration experiment for intensity response characteristics of digital color camera[J].Opto-Electronic Engineering,2006,33(6):101-105.(in Chinese)
DE MARTA L, JAUME P, MONTSERRAT A,et al.. Optiminzed algorithm for the spatial nonuniformity correction of an imaging system based on a charge-coupled device color camera[J].Applied Optics,2007,46(2):167-174.
刘亚侠.TDI CCD遥感相机标定技术的研究 . 长春:中国科学院长春光学精密机械与物理研究所,2005. LIU Y X. Research on the calibration technique of the TDI CCD remote sensing camera .Changchun:Changchun Institute of Optics,Fine Mechanics and Physics,2005.(in Chinese)
任建伟,万志,李宪圣,等. 空间光学遥感器的辐射传递特性与校正方法 [J]. 光学 精密工程,2007,15(8):1186-1190. REN J W,WAN ZH,LI X SH,et al..Radiation transfer characteristic and calibrating method for space optical remote sensor[J].Opt.Precision Eng.,2007,15(8):1186-1190. (in Chinese)
WIDENHORN R,DUNLAP J C,BODEGOM E. Exposure time dependence of dark current in CCD imagers[J].IEEE Transactions On Electron Devices,2010,57(3):581-587.
WIDENHORN R,HARTWIG I,DUNLAP J C,et al.. Influence of illumination on dark current in charge-coupled device imagers[J].Journal of Electronic Imaging,2009,18(3):033015-1-8.
GU Y, ERSON J M, MON K J G C. An approach to the spectral and radiometric calibration of the VIFIS system[J].Int J Remote Sensing, 1999,20(3):535-548.
林德荦. 资源一号卫星CCD相机辐射定标和图像辐射校正[J]. 航天返回与遥感,2000,21(2):8-13. LIN D L.Radiation calibration of CBERS-1 CCD camera and image radiation correction[J].Spacecraft Recovery & Remote Sensing,2000,21(2):8-13.(in Chinese)
WIDENHOM R,BLOUKE M M,REST A,et al.. Temperature dependence of dark current in a CCD[J]. SPIE,2002,4669:193-201.
杨臧健,符泰然,程晓舫,等. 彩色数字摄像机控制参数影响的标定[J]. 光学技术,2008,34(3):375-378. YANG Z J, FU T R, CHENG X F,et al.. Calibration for control parameters of digital color camera[J].Optical Techque,2008,34(3):375-378.(in Chinese)