LI Bao-sheng, LI Zheng-qiang, JI Feng, ZHOU Hai-yang. Measurement of aerosol absorption using photothermal low coherence interferometry[J]. Editorial Office of Optics and Precision Engineering, 2012,(8): 1704-1709
LI Bao-sheng, LI Zheng-qiang, JI Feng, ZHOU Hai-yang. Measurement of aerosol absorption using photothermal low coherence interferometry[J]. Editorial Office of Optics and Precision Engineering, 2012,(8): 1704-1709 DOI: 10.3788/OPE.20122008.1674.
Measurement of aerosol absorption using photothermal low coherence interferometry
The photothermal effect and thermal induced photorefraction change of aerosols in the atmosphere were researched. The method to improve detection sensitivity by increasing the number of photothermal effect zones and to reduce the costs by low coherence interferometry was proposed. A mathematics model to measure the aerosol absorption coefficients by photothermal low coherent interferomtry was established
the detection sensitivities from two ways
interferometric orthogonal measurement and interferometric fringe subdividing detecting
were analyzed
and the detecting limit in low coherent polarized interferometry was discussed. Experiments demonstrate that the detection sensitivity in theory can be 1?10
-6
m
-1
. If a longer interaction length and more number interaction zones are choosen
higher sensitivity can be arrived. The theory and method proposed in this paper can provide references for aerosol measurements.
关键词
Keywords
references
GADHAVI H, JAYARAMAN A. Absorbing aerosols: contribution of biomass burning and implications for radiative forcing[J]. Ann. Geophys., 2010,28(1):103-111.
STIER P, SEINFELD J H, KINNE S.Aerosol absorption and radiative forcing[J]. Atmos. Chem. Phys., 2007,7:5237-5261.
MOOSM LLER H, CHAKRABARTY R K, ARNOTT W P. Aerosol light absorption and its measurement: a review[J].J. Quant. Spectrosc. Radiat. Transfer, 2009,110(11):844-878.
黄书华,刘建国,刘文清,等. 高速大容量气溶胶粒子分类计数存储器的设计[J]. 光学 精密工程,2010,18(1):15-20. HUANG SH H, LIU J G, LIU W Q, et al..Design of high-speed and large-capacity classifying count storages for aerosol particles[J]. Opt. Precision Eng.,2010,18(1):15-20. (in Chinese)
李学彬,黄印博,徐赤东,等. 厦门地区气溶胶折射率的测量[J]. 光学 精密工程,2008,16(10):1831-1835. LI X B, HUANG Y B, XU CH D. Measurement of refractive index for aerosol particle in Xiamen[J].Opt. Precision Eng.,2008,16(10):1831-1835. (in Chinese)
王刚,禹秉熙. 基于对比度的空中红外点目标探测距离估计方法[J]. 光学 精密工程,2002,10(3):276-280. WANG G,YU B X. Approach to estimate infrared point target detection range against sky background based on contrast[J]. Opt. Precision Eng., 2002,10(3):276-280. (in Chinese)
BOND T C, ANDERSON T L, CAMPBELL D. Calibration and intercomparison of filter-based measurements of visible light absorption by aerosols[J]. Aerosol Science and Technology, 1999, 30:582-600.
杨小丽,罗九强,王俊波. 大气气溶胶粒子光吸收系数的测量[J]. 强激光与粒子束 ,2003,15(6):543-546. YANG X L,LUO J Q,WANG J B. Measurement of the absorption coefficient of light by aerosol particles in atmosphere[J]. High Power Laser and Particle Beams, 2003,15,(6):543-546. (in Chinese)
ANDERSON T L, MASONIS S J, COVERT D S, et al.. Variability of aerosol optical properties derived from in situ aircraft measurements duringace-asia[J]. J. Geophys. Res., 2003,108(D23):ACE15-1-19.
WEINGARTNER E, SAATHOFF H, SCHNAITER M, et al.. Absorption of light by soot particles: determination of the absorption coefficient by means of aethalometers[J]. Journal of Aerosol Science,2003,34(10):1445-1463.
PETZOLD A, SCH NLINNER M. Multi-angle absorption photometry—a new method for the measurement of aerosol light absorption and atmospheric black carbon[J]. Journal of Aerosol Science, 2004,35(4):421-441.
STRAWA A W, CASTANEDA R, OWANO T,et al..The measurement of aerosol optical properties using continuous wave cavity ring-down techniques[J]. Journal of Atmospheric and Oceanic Technology, 2003,20:454-465.
REY J M, MARINOV D, VOGLER DE,et al.. Investigation and optimisation of a multipass resonant photoacoustic cell at high absorption levels[J]. Applied Physics B: Lasers and Optics, 2005,80(2):261-266.
STEPHENS M, TURNER N, SANDBERG J,et al.. Particle identification by laser-induced incandescence in a solid-state laser cavity[J]. Applied Optics, 2003,42(19):3726-3736.
MICHELSEN H A, LIU F, KOCK B F,et al.. Modeling laser-induced incandescence of soot: asummary and comparison of LII models[J]. Applied Physics B: Lasers and Optics, 2007,87(3):503-512.
CAMPILLO A J, LIN H B. Method and apparatus for aerosol particle absorption spectroscopy:U.S.Patent,4415265 .1983.
LIN H B, CAMPILLO A J. Photothermal aerosol absorption spectroscopy[J]. Applied Optics, 1985,24:422-433.
MAZZONI D L, DAVIS C C. Trace detection of hydrazines by optical homodyne interferometry[J].Applied Optics, 1991,30(7):756-764.
MOOSM LLER H, ARNOTT W P, ROGERS C F. Methods for real-time,in site measurement of aerosol light absorption[J]. Journal of The Air & Waste Management Association,1997,47:157-166.
OWENS M A, DAVIS C C, DICKERSON R R. A photothermal interferometer for gas-phase ammonia detection[J]. Anal. Chem., 1999, 71:1391-1399.
SEDLACEK A, LEE J. Photothermal interferometric aerosol absorption spectrometry[J]. Aerosol Science and Technology, 2007, 41:1089-1101.
CHAN C H. Effective absorption for thermal blooming due to aerosols[J]. Appl. Phys. Lett.,1975, 26:628.
JACKSON J D. Classical Electrodynamics[M]. Wiley, 1962:121-123.
BORN M, WOLF E. Principles Of Optics[M]. 7th.Ed..Chinese Version.Publishing House Of Electrics Industry,1999,79-81.
MOOSM LLER H, ARNOTT W P. Folded jamin interferometer: a stable instrument for refractive-index measurement[J]. Optics Letters, 1996,21(6):438-440.