In consideration of the effect of stray light on the measurement accuracy of a space-borne differential optical absorption spectrometer for monitoring atmospheric trace gases
several stray light removing mechanisms including a light shield and other baffles were developed to suppress the stray light
and the properties of the stray light were analyzed. With TracePro model
the stray light removing of UV channel 1(240-315 nm) in the system was evaluated
then the first and second order scattering paths were determined by simulation analysis. On the basis of stray light paths
the stray light removing for revised system was analyzed
and Point Source Transmittance(PST) was calculated. The obtained PST value shows that the light shield and other mechanisms have suppressed the stray light effectively
PST values are less than 310
-5
and stray radiation ratio in a central field is 5.47210
-4
. Furthermore
the final stray light suppressing level of the system satisfies the requirement of design index. Moreover
the edge filter method is used to measure the stray light level
and the results indicate that the stray light in the central field is 8.16710
-4
which is close to the simulation results and proves the simulation result to be credible.
关键词
Keywords
references
PITERNEL F L, GIJSBERTU H J, MRCEL R D, et al.. The ozone monitoring instrument [J]. IEEE Trans. Geosci. Remote Sens., 2006, 44(5):1093-1101.[2] 张军强,吴清文,颜昌翔.星载成像光谱仪杂散光测量与修正[J]. 光学 精密工程, 2011,19(3):552-560. ZHANG J Q, WU Q W,YAN CH X. Measurement and correction of stray light of space-borne high resolution imaging spectrometer [J]. Opt. Precision Eng., 2011, 19(3) : 552-560. (in Chinese)[3] PLATT U, PERNER D. Differential optical absorption spectroscopy(DOAS), principles and applications[M]. German: Springer, 2008: 625-630.[4] 钟兴,贾继强. 空间相机消杂光设计及仿真[J]. 光学 精密工程, 2009, 17(3):621-625. ZHONG X, JIA J Q. Stray light removing design and simulation of space-borne camera [J]. Opt. Precision Eng., 2009, 17(3) : 621-625. (in Chinese)[5] PETERSON G L.Stray light calculation methods with optical ray trace software [J]. SPIE, 1999, 3780:132-137.[6] STAUNDER J L. Stray light comparison of off-axis and on-axis telescopes. USA: Utha State University, 2000.[7] 邹刚毅,樊学武. 离轴三反射望远镜遮光罩设计与杂光分析[J]. 光子学报, 2009, 38(3):605-609. ZOU G Y, FAN X W. Baffle design and stray light analysis of the off-axis three mirror telescope [J]. Acta Photonica Sinica, 2009, 38(3): 605-609. (in Chinese)[8] Lambda Research Corporation. Tracepro User Manual [M]. Littleton : Lambda Research Corporation, 2005.[9] BAUMER S. SLIOS-a contribution to standard procedures in stray light measurements [J].SPIE, 1999, 3739: 414-421.[10] HARVEY J E, KOTHA A. Scattering effects from residual optical fabrication errors [J]. SPIE, 1995, 2576: 155-174.[11] Lambda Research Corporation.EO-1 stray light analysis report No.3. Lambda Research Corporation, 1998:5-7.[12] 李婷,杨建峰,阮萍,等. 月基光学天文望远镜(LOT)的杂散光分析[J]. 光子学报, 2007, 36:136-141. LI T, YANG J F, RUAN P, et al.. Stray light analysis of the lunar-based optical telescope [J]. Acta Photonica Sinica, 2007, 36:136-141. (in Chinese)[13] 张红鑫,卢振武,夏利东,等. 白光日冕仪光系统的杂散光抑制[J]. 光学 精密工程, 2009, 17(10) : 2371-2376. ZHANG H X, LU ZH W, XIA L D, et al.. Stray light suppressing of optical system in white light coronagraph [J]. Opt. Precision Eng., 2009, 17(10) : 2371-2376. (in Chinese)[14] 张军强,吴清文,颜昌翔.星载超光谱成像仪杂散光及其测量[J]. 光谱学与光谱分析,2010,30(10):2861-2865. ZHANG J Q, WU Q W, YAN CH X. Stray light of space-borne hyperspectral imager and its measurement [J]. Spectroscopy and Spectral Analysis,2010, 30(10):2861-2865. (in Chinese)
Key Laboratory of Environmental Optical and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences
Information Materials and Intelligent Sensing Laboratory of Anhui Province, Anhui University
Institutes of Physical Science and Information Technology, Anhui University
Shanghai Institute of Technical Physics, Chinese Academy of Sciences