To improve the precise of all automatic printing equipment
a simple and effective calibration method was proposed to calibrate the screen printing equipment based on a novel three-degree-of-freedom (3-DOF) planar parallel stage. Firstly
a vision-based measuring system was analyzed and calibrated
and its measurement accuracy was also evaluated by a laser interferometer. Then
the geometric errors of the 3-DOF planar parallel stage was analyzed and the frame of the parallel stage's movable platform
screw lead errors and some geometric errors were identified in steps based on a vision-based measuring system in the equipment. Furthermore
the orientation interpolation and alignment methods using a triangular area to position the alignment point were presented to satisfy the need for different product processes in the whole workspace. For the processing mentioned above
this calibration method can calibrate the equipment itself automatically without complicated identification for all geometric errors and the need for any background in parallel robot calibration. Experimental results after calibration show that the maximum position and orientation errors inside the workspace have been reduced from 161.6 μm and 2.232″ to 12.3 μm and 0.720″
respectively
which satisfies the equipment requirement for high accuracy.
关键词
Keywords
references
PAN J, STORER R, SALLADE R, et al.. Critical variables of solder paste stencil printing for micro-BGA and fine-pitch QFP [J]. IEEE Trans. on Electron. Pack., 2004,27(2):125-132. [2]JU M, LEE Y, LEE J, et al.. Double screen printed metallization of crystalline silicon solar cells as low as 30 μm metal line width for mass production[J]. Sol. Energ. Mat. Sol. C., 2012, 100: 204-208.[3]YU A, BONEV I, ZSOMBOR-MURRAY P. New XY-Theta positioning table with partially decoupled parallel kinematics[C]. Proceeding of the IEEE Int. Symp. On Ind. Electron., Montreal, QC, Canada: ISIE, 2006:3108-3112.[4]高猛, 李铁民, 唐晓强. 少自由度并联机床标定试验研究[J]. 机械工程学报, 2003, 39(9): 118-122.GAO M, LI T M, TANG X Q. Calibration experiment research of parallel kinematics machine with a few degrees[J]. Chinese J. of Mech. Eng., 2003, 39(9):118-122. (in Chinese)[5]JOUBAIR A, SLAMNI M, BONEV I. A novel XY-Theta precision table and a geometric procedure for its kinematic calibration[J]. Robot. Cim.-Int. Manuf., 2012, 28: 57-65.[6]CHANG P, WANG J S, LI T M, et al.. Step kinematic calibration of a 3-DOF planar parallel kinematic machine tool[J]. Sci. China Ser. E-Tech. Sci., 2008, 51(12): 2155-2167.[7]何小妹, 丁洪生, 付铁, 等. 并联机床运动学标定研究综述[J]. 机床与液压, 2004, 10: 9-11.HE X M DING H SH, FU T, et al.. Review on kinematic calibration of parallel kinematic machine[J]. Mach. Tool & Hydraulics,2004, 10:9-11. (in Chinese)[8]ZOU H, NOTASH L. Discussion on the camera-aided calibration of parallel manipulators[C]. Proceeding of CCToMM Symp. Mech. Mach., and Mechatron., Saint-Hubert, QC, Canada: CD-ROM, 2001:1-2.[9]LIANG J L, KUANG Y C, CHEN J Z, et al.. A novel XY-Theta alignment stage for screen printing and its accuracy analysis[C]. Proceeding of the IEEE Int. Conf. on Mech. and Autom., Chengdu, China: ICMA, 2012:1352-1357.[10]张宪民, 邝泳聪, 卢盛林, 等. 用于锡膏印刷的L型双镜头图像采集装置.中国:ZL20060123893.4[P].2007-05-30.ZHANG X M, KUANG Y C, LU SH L, et al.. A L type double cameras image acquisition device for automatic screen printer. China:ZL20060123893.4[P].2007-05-30.[11]MERLET J-P. Direct kinematic of planar parallel manipulators[C]. Proceeding of the IEEE Int. Conf. on Robot. and Autom., Minneapolis, USA: ICRA, 1994:3744-3749.[12]BRAND P, MOHR R. Accuracy in iamge measure[C]. Proceeding of SPIE Conf. Videometrics III, Vol. 2350, Boston, Ma, USA, 1994: 218-228.[13]王建民, 浦昭邦, 赵辉, 等. 一种新的二维图像测量系统标定方法[J]. 哈尔滨工业大学学报, 2000, 32(3):37-41.WANG J M, PU ZH B, ZHAO H, et al.. A new method for calibrating 2-D image measuring systems[J]. J. of Harbin Institute of Technology, 2000, 32(3):37-41. (in Chinese)[14]张舞杰, 杨义禄, 李迪, 等. 自动影像测量系统关键算法[J]. 光学 精密工程, 2007, 15(2):294-301.ZHANG W J, YANG Y L, LI D, et al.. Key algorithms of automatic image measurement system[J]. Opt. Precision Eng., 2007, 15(2):294-301. (in Chinese)[15]梁经伦, 张宪民, 莫景会. 一种XY-Theta并联平台精度分析及标定[J]. 华南理工大学学报, 2012, 11.LIANG J L, ZHANG X M, MO J H. Accuracy analysis and calibration of a XY-Theta parallel stage[J]. J. of South China University of Technology, 2012,11. (in Chinese)[16]Manipulating industrial robots—performance criteria and related test methods, ISO 9283, 1998.