YANG Zhen-Ling FANG Wei WANG Kai JIANG Ming SONG Bao-qi. Field of View Measurement and Correction Term Calculation for Small-Field Radiometer[J]. Editorial Office of Optics and Precision Engineering, 2013,21(4): 870-875
YANG Zhen-Ling FANG Wei WANG Kai JIANG Ming SONG Bao-qi. Field of View Measurement and Correction Term Calculation for Small-Field Radiometer[J]. Editorial Office of Optics and Precision Engineering, 2013,21(4): 870-875 DOI: 10.3788/OPE.20132104.0870.
Field of View Measurement and Correction Term Calculation for Small-Field Radiometer
Solar Irradiance Monitor (SIM) on the FY-3C satellite was designed to be a Small-field-of-view Radiometer (SFoV-R) with a precise solar pointing system to decrease the measurement uncertainty derived from the wide field-of-view of SIM on FY-3A and FY-3B satellites. To obtain the measurement uncertainty derived from the SFoV-R
the field-of-view of SFoV-R on FY-3C satellite determined by a view-limiting aperture and a precision aperture was calculated. Based on this field-of-view
a theoretical change curve of the measured irradiance incidence angle was achieved. Then
an actual measurement of the change curves was performed. The result indicates that the relative deviation on an average between the theoretical and measured change curves is 1%-2%
which is close to the limit accuracy of the measuring installation and proves the veracity of the calculated values for field-of-view. The correction term of radiation exchange between space and the radiometer is estimated to be 2.023 W/m2 based on the calculated field-of-view. Experiments show that the standard deviation of this correction term can be neglected compared to the requirement of solar irradiance measurement accuracy.
关键词
Keywords
references
方伟,禹秉熙,王玉鹏,等.太阳辐照绝对辐射计及其在航天器上的绝对辐射测量[J].中国光学,2009,2(1):23-28.FANG W, YU B X, WANG Y P, et al. Solar irradiance absolute radiometers and solar irradiance measurement on spacecraft [J]. Chinese Journal of Optics,2009,2(1):23-28. (in Chinese)[2]WANG H R, FANG W. Solar irradiance absolute radiometer with ability of automatic solar tracking[J]. Chinese Optics, 2011, 4(3):252-258.[3]WANG H R, WANG Y P. Spaceborne radiometer for measuring total solar irradiance [J]. Chinese Optics, 2012, 5(6):555-565.[4]禹秉熙,方伟,王玉鹏.卫星上绝对辐射计观测太阳时与太空的辐射交换[J].光学学报,2005,25(8):1048-1052.YU B X, FANG W, WANG Y P. The radiation exchange between the space and the absolute radiometer along with the solar observation on spacecraft[J]. Acta Optica Sinica, 2005,25(8):1048-1052.(in Chinese)[5]王玉鹏,方伟,禹秉熙.宽视场绝对辐射计的杂散光特性[J]. 光学 精密工程,2008,16(3):433-437.WANG Y P, FANG W, YU B X. Stray light characteristics of WFOV absolute radiometer[J]. Opt. Precision Eng., 2008, 16(3):433-437. (in Chinese)[6]禹秉熙,方伟,王玉鹏.卫星宽视场绝对辐射计太阳越过视场时入射光变化与腔温响应函数[J]. 光学 精密工程,2004, 12(4):353-358.YU B X, FANG W, WANG Y P. Radiation exchange and temperature response function of the absolute radiometer with wide field of view mounted on the satellite [J]. Opt. Precision Eng., 2004, 12(4):353-358.(in chinese)[7]王伟. 太阳辐照度监测仪比对与校正研究[D].长春:中国科学院长春光学精密机械与物理研究所, 2004.WANG W. Inter-Comparison and Correction of Solar Irradiance Monitor[D]. Changchun:Changchun Institute o f Optics, Fine Mechanics and Physics, Chinese Academy of Sciences,2004. (in Chinese)[8]王红睿,王玉鹏,方伟. 智能双模式太阳跟踪器[J]. 光学 精密工程,2011,19(7):1605-1611.WANG H R, WANG Y P, FANG W. Intelligent solar tracker with double modes[J]. Opt. Precision Eng., 2011,19(7):1605-1611.(in Chinese).[9]王玉鹏,方伟,弓成虎,等. 双腔互补偿型绝对辐射计[J]. 光学 精密工程,2007,15(11):1662-1667.WANG Y P,FANG W,GONG CH H, et al.. Dual cavity inter-compensating absolute radiometer[J]. Opt. Precision Eng., 2007, 15(11):1662-1667.(in Chinese)[10]方伟. 双腔互补偿型绝对辐射计[D]. 中国科学院长春光学精密机械与物理研究所, 2005.FANG W. Dual Cavity Inter-Compensate Absolute Radiometer (DCICAR)[D]. Changchun:Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy o f Sciences, 2005. (in Chinese)[11]王伟,方伟,禹秉熙,等. FY-3卫星太阳辐射监测仪星上测量校正因子的研究[J]. 长春理工大学学报,2003, 26(3):87-91.WANG W, FANG W, YU B X, et al.. Research on calibrated factors of STIM on FY-3 satellite[J]. Journal of Changchun University of Science and Technology, 2003, 26(3):87-91.(in Chinese)[12]KOPP G, LAWRENCE G, ROTTMAN G. The total irradiance monitor (TIM): science results[J]. Solar Physics, 2005, 230:129-139.