Design of thermal stable Fabry-Perot etalon for measuring wind
In consideration of the effect of thermal stability of a Fabry-Perot(F-P) etalon in the satellite-borne F-P interferometer on wind measurement
this paper analyzes the thermal stability of the F-P etalon from its construction design including materials
shapes and fixed forms
then
it optimizes the design. With optimization design
the optical elements in the etalon are constructed
which shows that the two plates are all 25 mm thick
and the spacers are all 40 in angles. Then
the dimensions of mechanical structure of the etalon are calculated using flexible structure. Finally
the thermal distortions of optical elements and the etalon are discussed. It shows that the gap dimension changes in the centers of the optical elements and the etalon are 0.64 nm and 0.28 nm and the gap dimension change of the etalon is 0.2 nm when the temperature changes 0.1 ℃. Furthermore
the airglow spectral lines are ~/2 250 and ~/3 150 at 630 nm respectively
and the gap dimension changes of the etalon fall along the radius from the center to the verge. These results demonstrate that optimized structure parameters meet the requirements of measuring accuracy for thermal stability and mechanical stability at a wind velocity of 5 m/s.
关键词
Keywords
references
HIDEAKI N,SHOICHI O , HIROSHI F,et al.. Observation of thermospheric wind velocities and temperatures by the use of Fabry-Perot Doppler imaging system at Syowa Station, Antarctica [J]. Applied Optics,1995,34(36):8382-8395. [2]卢锷,牛晓明,孙同和,等.基于CAD/CAE/CAT技术的空间遥感相机热设计研究光学[J]. 光学 精密工程,1998,6(5):21-32.LU E,NIU X M, SUN T H,et al.. Study on thermal control design of space camera based on CAD/CAE/CAT [J]. Opt. Precision Eng.,1998,6(5):21-32. (in Chinese)[3]王平,王汝冬,田伟,等.Fizeau干涉仪主机的热稳定性设计与分析[J]. 光学 精密工程,2011,19(9):2100-2107.WANG P,WANG R D,TIAN W,et al.. Design and analysis of thermal stability for main frame in Fizeau interferometer[J]. Opt. Precision Eng., 2011,19(9):2100-2107. (in Chinese)[4]赵鹏,卢锷,王家骐.空间光学仪器光、机、热一体化总体设计光学[J]. 光学 精密工程,1996,4(6):17-21.ZHAO P, LU E,WANG J Q. Integrated design for space optical instrument [J]. Opt. Precision Eng.,1996,4(6):17-21. (in Chinese)[5]PAUL B H, VINCENT J A, MICHAEL E D,et al.. The high-resolution doppler imager on the upper atmosphere research satellite[J]. Journal of Geophysical,1993,98(D6):10,713-723.[6]WILBER R S, PAUL B H, HEINZ J G, et al.. The high resolution doppler imager:instrument performance in orbit since late 1991[J].SPIE, 2830:202-214.[7]WILBERT R S, RICK J N, TIMOTHY L K,et al.. Operational performance of the TIMED doppler interferometer(TIDI)[J]. Proceedings of SPIE, 2003,5175:47-57.[8]朱益清,王小力,朱拓. 具有温度稳定的法布里-珀罗标准具设计[J]. 江南大学学报(自然科学版),2007,6(4):438-441.ZHU Y Q, WANG X L, ZHU T. The thermally stable Fabry-Perot etalon devices made of crystals[J]. Journal of Jiangnan University(Natural Science Edition), 2007,6(4):438-441. (in Chinese)[9]REES D, FULLER R, LYONS A, et al.. Stable and rugged etalon for the dynamics explorer fabry-perot interferometer [J]. Applied Optics,1982,21(21): 3896-3912.[10]苗恩铭. 材料热膨胀系数影响因素概述[J]. 工具技术,2005,39(5):26-29.MIAO E M. Applicability analysis and extension choice of using thermal expansion character Parameter [J]. Tool Engineering,2005,39(5):26-29. (in Chinese)[11]刘盛举,曹俊卿. 关于法布里-珀罗标准具的研究[J].大学物理,2003,22(6):26-28.LIU SH J , CAO J Q. Research on Fabry-Perot etalon [J]. College Physics, 2003,22(6):26-28. (in Chinese)