陈剑鸣 吕启蒙 吴光敏 楚合群 John D Mai. 分子印迹型薄膜体声波谐振毒品检测传感器[J]. 光学精密工程, 2013,21(9): 2272-2278
CHEN Jian-ming LV Qi-meng WU Guang-min CHU He-qun John D Mai. Molecularly imprinted sensor integrated with thin-film bulk acoustic resonator for drug detection[J]. Editorial Office of Optics and Precision Engineering, 2013,21(9): 2272-2278
陈剑鸣 吕启蒙 吴光敏 楚合群 John D Mai. 分子印迹型薄膜体声波谐振毒品检测传感器[J]. 光学精密工程, 2013,21(9): 2272-2278 DOI: 10.3788/OPE.20132109.2272.
CHEN Jian-ming LV Qi-meng WU Guang-min CHU He-qun John D Mai. Molecularly imprinted sensor integrated with thin-film bulk acoustic resonator for drug detection[J]. Editorial Office of Optics and Precision Engineering, 2013,21(9): 2272-2278 DOI: 10.3788/OPE.20132109.2272.
Molecularly imprinted sensor integrated with thin-film bulk acoustic resonator for drug detection
A highly sensitive and high selective sensor which can detect drug molecules in a liquid environment was explored. By combining the Molecular Imprinting Technique (MIT),Film Bulk Acoustic Resonator (FBAR) and the micro fluidic technology
the new sensor was constructed. The preparing principle of adsorption layer materials for FBAR by the MIT was introduced and the Imprinting material with special adsorption properties for the special drug was developed by the MIT. Then
the material was coated on a FBAR as a adsorption layer based on a Micro-electrical-mechanical System and the micro fluidic technology. According to the piezoelectric equation and dynamic equation
the input impedance formulas of the equivalent circuit and electric port for the FBAR piezoelectric vibrator were derived. Furthermore
a model of the micro fluidic system with the MIT plus FBAR-based drug detection sensor was designed and a detailed theoretical derivation and analysis was performed. Finally
the sensor model was simulated using practical operating parameters. The results show that the quality of the mass loudness per unit area of the sensor is up to 0.8 pg/Hzcm2
which is much higher than the quality of a conventional Quartz Crystal Microbalance (QCM) sensor. This advantage can greatly enhance the performance of the sensor for drug detection in the liquid environment.
关键词
Keywords
references
郝红霞, 刘建军, 韦天新. 分子印迹技术在毒品检测中的应用[J]. 中国法医学杂志, 2009, 24(5): 315-317.HAO H X, LIU J J, WEI T X. Application of molecular imprinting technique in drug detection [J]. Chin. J. Forensic Med., 2009, 24(5): 315-317. (in Chinese)[2]TOKONAMI S, SHIIGI H, NAGAOKA T. Review: Micro-and nanosized molecularly imprinted polymers for high-throughput analytical applications [J]. Analytica chimica acta, 2009, 641(1): 7-13.[3]COOPER M A, SINGLETON V T. A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions [J]. Journal of Molecular Recognition, 2007, 20(3): 154-184.[4]FU Y Q, LUO J K, DU X Y, et al.. Recent developments on ZnO films for acoustic wave based bio-sensing and microfluidic applications: a review [J]. Sensors and Actuators B: Chemical, 2010, 143(2): 606-619.[5]莫绍孟, 陈剑鸣, 吴光敏, 等. 独特谐振模式下薄膜体声波谐振器的设计[J]. 光学 精密工程, 2009, 17(6): 1251.MO SH M, CHEN J M, WU G M, et al.. Design of thin film bulk acoustic resonator under unique mode [J]. Opt. Precision Eng., 2009, 17(6): 1251. (in Chinese)[6]LIN R C, CHEN Y C, CHANG W T, et al.. Highly sensitive mass sensor using film bulk acoustic resonator [J]. Sensors and Actuators A: Physical, 2008, 147(2): 425-429.[7]KANDIMALLA V B, JU H. Molecular imprinting: a dynamic technique for diverse applications in analytical chemistry [J]. Anal Bioanal Chem., 2004, 380(4): 587-605.[8]TOAL S J, TROGLER W C. Polymer sensors for nitroaromatic explosives detection[J]. J. Mater. Chem., 2006, 16(28): 2871-2883.[9]ZHANG H. Micromachined Bulk Acoustic Resonators for Radio-frequecy Systems and Biochem Mass sensing[D].California:University of Southern California, 2006.[10]CHU H Q, WU G M, CHEN J M, et al.. Design and simulation of self-powered radio frequency identification (RFID) tags for mobile temperature monitoring [J]. Sci. China Tech., 2013, 56(1):1-7.[11]傅建中, 贺永, 陈子辰. 微流体芯片中流体温度软测试技术研究[J]. 光学 精密工程, 2004, 12(3):140-143.FU J ZH, HE Y, CHEN Z CH. Research on soft-sening of fluid temperature in microfluidic chip [J]. Opt. Precision Eng., 2004, 12(3):140-143. (in Chinese)[12]VOGT B D, LIN E K, WU W, et al.. Effect of film thickness on the validity of the sauerbrey equation for hydrated polyelectrolyte films [J]. The Journal of Physical Chemistry B, 2004, 108(34): 12685-12690.[13]李侃. FBAR微质量传感器若干关键问题的研究[D]. 杭州: 浙江大学, 2011.LI K. A Study on Thin Film Bulk Acoustic Resonator (FBAR) for Mass Sensor Application[D]. Hangzhou: Zhejiang University, 2011.(in Chinese)