the measurement accuracy will decrease due to the reversal error of time-of-flight measurement. In this paper
a method to correct the reversal error is described in detail. The correction method proposed here included two steps: prior modeling calibration and reversal error correction. Firstly
the function relationship between laser pulse response rate and reversal error was obtained by the calibration method and the reversal error prediction function was established. Then
the reversal error of an original 3D image was calculated by the reversal error prediction function and the 3D image was corrected. Finally
a photon counting 3D imaging lidar system was constructed
in which the Geiger mode Avalanche Photodiode(Gm-APD) was used as a photon detector and the high-speed galvanometer as a scanner. A Time Correlation Single Photon Counting (TCSPC) module was used to mark the arrival time of each photon event. The original 3D image and laser pulse response rate were acquired by the arrival time distribution of photon events. In performance evaluation test
the mean square error of ranging results is improved from 33.2 mm to 8.1 mm after correction. The reversal error correction method proposed in this paper effectively reduces the reversal error caused by the energy fluctuation of laser echo pulse in the photon counting 3D imaging lidar.
关键词
Keywords
references
CHEN F,BROWN G M, SONG M M. Overview of three-dimensional shape measurement using optical methods [J]. Opt. Eng., 2000, 39:10-22.[2]MASSA J S,WALLACE A M, BULLER G S, et al.. Laser depth measurement based on time-correlated single-photon counting [J]. Opt. Lett., 1997, 22:543-545.[3]MARINO R M,DAVIS W R. Jigsaw: a foliage-penetrating 3D imaging laser radar system [J]. Lincoln Lab. J, 2005, 15: 23-36.[4]WARBURTON R E,MCCARTHY A,WALLACE A M, et al.. Sub-centimeter depth resolution using a single-photon counting time-of-flight laser ranging system at 1550 nm wavelength [J]. Opt. Lett., 2007, 32: 2266-2268.[5]OH M S,KONG H J,KIM T H, et al.. Time-of-flight analysis of three-dimensional imaging laser radar using a geiger-mode avalanche photodiode [J]. Japanese Journal of Applied Physics, 2010, 49: 026601-1-026601-6.[6]GATT P, JOHNSON S, NICHOLS T. Geiger-mode avalanche photodiode ladar receiver performance characteristics and detection statistics [J]. Appl. Optics, 2009, 48(17): 3261-3276.[7]WANG F,ZHAO Y,ZHANG Y, et al.. Range accuracy limitation of pulse ranging systems based on Geiger mode single-photon detectors [J]. Appl. Opt., 2010, 49: 5561-5566.[8]KIRCHNER G,KOIDL F. Time walk compensated SPAD: multiple photon versus single photon operation [J]. SPIE, 1997, 3218: 106-112.[9]OH M S,KONG H J,KIM T H, et al.. Reduction of range walk error in direct detection laser radar using a Geiger mode avalanche photodiode [J]. Optics Communications, 2010, 283: 304-308.[10]MCCARTHY A,COLLINS R J,KRICHEL N J, et al.. Long-range time-of-flight scanning sensor based on high-speed time-correlated single-photon counting [J]. Appl. Optics, 2009, 48 (32): 6241-6251. [11]OH M S,KONG H J,KIM T H, et al.. Development and analysis of a photon-counting three-dimensional imaging laser detection and ranging (LADAR) system [J]. Opt. Soc. Am, 2011, 28: 759-765.