LENG Xue,ZHANG Xue-fei,LI Wen-ming etc. Image defect of full-frame CCD in TDI mode[J]. Editorial Office of Optics and Precision Engineering, 2014,22(2): 467-473
LENG Xue,ZHANG Xue-fei,LI Wen-ming etc. Image defect of full-frame CCD in TDI mode[J]. Editorial Office of Optics and Precision Engineering, 2014,22(2): 467-473 DOI: 10.3788/OPE.20142202.0467.
When a long focal area-array CCD camera takes photos in a TDI mode for dynamic lateral multi-frame imaging
it will output images with large size defect on the edge of image because of the high line transfer frequency or long exposure time and will influence image interpretation. To overcome the problems
the operating principle of area-array CCD in the TDI mode was analyzed
and the analysis indicates that the large size defect in the image comes from the invalid TDI transfer stages of the CCD during shutter exposure process. The obtained results were verified by a experiment and a method that the TDI transfer was finished simultaneously with shutter exposure was proposed to remove the invalid TDI transfer. On the basis of the analysis
a photo-electricity positioning synchronized was proposed and a photo-electricity synchronizer was developed to settle the headache. The results show that the image defect area is less than 15 column-pixels
which successfully solves the image defect from the area-array CCD camera in the TDI mode and improves its image interpretation accuracy.
QU H F,WANG X D,LV B L. Non-uniformity correction of mutiple output area CCD image [J]. Chinese Journal of Liquid Crystals and Displays, 2012,27(4): 569-572. (in Chinese)
LIU Y Y,LI G N,ZHANG Y,et al.. Detection and correction of response non-uniformity based on visible light area CCD[J]. Chinese Journal of Liquid Crystals and Displays, 2010,25(5): 759-763.(in Chinese)
ZHANG CH SH. Design of driving circuit for area array CCD based on FPGA [J]. Chinese Journal of Liquid Crystals and Displays, 2012,27(6):789-794.(in Chinese)
XUE X CH,HAN CH SH,XUE D L,et al.. Increasing dynamic range of space push-broom remote sensing camera by two-row TDI CCD[J]. Opt. Precision Eng., 2012,20(12):2791-2795. (in Chinese)
ZHANG X F,DING Y L,LI X Y,et al..Discrete-time sliding-mode control in panoramic aerial camera[J].Control Theory & Applications, 2012,29(9):1163-1168. (in Chinese)
LAREAU A G.Electro-optical imaging array with motion compensation[J]. SPIE, 1993, 2023:65-79.
LENG X,ZHANG H W,LIU M,et al.. Design of large format focal-plane shutter with high frame-frequency and orthogonality [J]. Opt. Precision Eng., 2011,19(11) :2630-2635. (in Chinese)
ZHANG L,DING Y L,ZHANG H W. New single curtain type shutter used on aerial camera [J]. Infrared and Laser Engineering, 2012,41(7):1815-1820. (in Chinese)