SUN Zhi-yuan, CHANG Song-tao, ZHU Wei etc. Radiation calibration of infrared system by amendment of inner and outer calibrations[J]. Editorial Office of Optics and Precision Engineering, 2015,23(2): 356-362
SUN Zhi-yuan, CHANG Song-tao, ZHU Wei etc. Radiation calibration of infrared system by amendment of inner and outer calibrations[J]. Editorial Office of Optics and Precision Engineering, 2015,23(2): 356-362 DOI: 10.3788/OPE.20152302.0356.
Radiation calibration of infrared system by amendment of inner and outer calibrations
As the existing radiation calibration for a shortwave infrared system with large aperture needs a huge infrared collimator and has poor motility and cost much
this paper proposes a new calibration method based on the amendment of inner and outer calibrations. This method sets a middle-high temperature cavity blackbody in the infrared system. By switching a mirror
it introduces the blackbody radiation into the infrared system to implement the inner calibration on parts of system at the middle-high temperature range. Then it uses a huge area blackbody to implement the outer calibration on the whole system at middle temperature range. The inner and outer calibration data at the common temperature range are picked up to calculate the amendatory coefficient in whole system. Finally
the radiation calibration data for whole system at the middle-high temperature range are captured by amending the inner calibration data. With this method
an
Φ
400 mm infrared system is calibrated
and the luminance error and temperature error are inverted based on the calibration results. The results show that the maximal luminance error is 1.67% and the maximal temperature error is 1.02 ℃. The results indicate that the proposed method is precise and effective for the radiation calibration of shortwave infrared systems with large apertures.
关键词
Keywords
references
HUDSON R D. Infrared System Engineering[M].John Wiley & Sons.Inc.,1969.
RICE J P, BENDER S C, ATKINS W H, et al.. Deployment test of the NIST EOS thermal infrared transfer radiometer [J]. International Journal of Remote Sensing, 2003, 24(2):367-388.
THEOCHAROUS E, FOX N P, SAPRITSKY V I, et al.. Absolute measurements of black body emitted radiance [J]. Metrologia, 1998, 35(4):549-554.
THOMAS S, INGMAR R. A study of the radiometric calibration of spectral bands in the mid wave infrared (MWIR) spectral range, 1.5-5.5μm [J]. SPIE, 2009, 7300:73000Z.
WOLFE W L. Introduction to Radiometry [M]. SPIE Optical Engineering Press, 1998.
LI X SH, REN J W, ZHANG L G, et al.. Research on a radiometric calibration device for a large aperture infrared opto-electric on spot [J]. Journal of Optoelectronics·Laser, 2006, 17(2): 175-178. (in Chinese)
ZHAI W CH, LI J J, ZHENG X B, et al.. Research on method of calibration sun channels of sun radiometers [J]. Acta Optica Sinica, 2012, 32(4):0412004. (in Chinese)
TANG J, GAO X. Calibration method for radiation characteristics measuring system of test range [J]. Infrared and Laser Engineering, 2006, 35(10):266-270. (in Chinese)
LUO M J, ZHOU J M, FU J N, et al.. Integration time as variable for radiometric calibration of infrared system [J]. Infrared and Laser Engineering, 2013, 42(1):36-40. (in Chinese)
YANG C Y, ZHANG J P, CAO L H. Infrared radiation measurement based on proportional corrected atmospheric transmittance [J]. Opt. Precision Eng., 2012, 20(7):1626-1635. (in Chinese)
ZHANG X L, LIU Y, SUN Q, et al.. Radiometric calibration of uncooled long-wave infrared thermal imager with high-precision [J]. Chinese Optics, 2012, 5(3):235-241. (in Chinese)
ZHANG X L, LIU Y, WANG J, et al.. Infrared thermometry technology with different nonuniformity correction temperatures [J]. Chinese Optics, 2014, 7(1):150-155. (in Chinese)
LI N, YANG C Y, CAO L H, et al.. Radiance calibration for 3-5 μm infrared focal plane array[J]. Opt. Precision Eng., 2011, 19(10):2319-2325. (in Chinese)