LIU Hai-long, HAN Cheng-shan, LI Xiang-zhi etc. Vibration parameter measurement of TDICCD space camera with mechanical assembly[J]. Editorial Office of Optics and Precision Engineering, 2015,23(3): 729-737
LIU Hai-long, HAN Cheng-shan, LI Xiang-zhi etc. Vibration parameter measurement of TDICCD space camera with mechanical assembly[J]. Editorial Office of Optics and Precision Engineering, 2015,23(3): 729-737 DOI: 10.3788/OPE.20152303.0729.
Vibration parameter measurement of TDICCD space camera with mechanical assembly
To obtain the vibration amplitude-frequency characteristics of a in-orbit space camera
a space camera vibration parameter detection method by using TDICCD mechanical assembly technique was presented. According to TDICCD mechanical assembly technology
the images of same scene were taken by a TDICCD overlapping area at different moments
then the images were compared by using gray projection algorithm to derive the relative offset. Finally
the offset data were fitted
and the vibration parameters of the space camera were obtained according to the fitting result. Experimental results show that frequency measurement relative error and the amplitude measurement absolute error are less than 0.5% and 1 pixel respectively for the one dimensional single frequency vibration; and those are less than 3% and 2 pixel respectively for one dimensional mixed frequency vibration. Moreover
for two dimensional vibration which are both single frequency vibration along and vertical to the scanning direction
the frequency measurement error and the amplitude measurement error are less than 1% and 2 pixel
Respectively. Experimental results demonstrate the correctness of detection methods
reach the purpose of detecting vibration parameters without additional facilities except the camera structure
and provide a data base for the subsequent image restoration.
关键词
Keywords
references
石俊霞, 郭永飞, 薛旭成, 等. 航天时间延迟积分CCD相机振动模糊图像的恢复 [J]. 光电子·激光, 2012, 23(3):572-578. SHI J X, GUO Y F, XUE X CH, et al.. Motion blurred image restoration of spaceborne TDICCD camera [J]. Journal of Optoelectronics Laser, 2012, 23(3):572-578. (in Chinese)
CHENG H Y. A high-resolution airborne four-camera imaging system for agricultural remote sensing [J]. Computers and Electronics in Agriculture, 2012, 88:13-24.
薛旭成, 韩诚山, 薛栋林, 等. 应用双排TDICCD提高空间推扫遥感相机动态范围 [J]. 光学 精密工程, 2012, 20(12):2791-2795. XUE X CH, HAN CH SH, XUE D L, et al.. Increasing dynamic range of space push-broom remote sensing camera by two-row TDICCD [J]. Opt. Precision Eng. , 2012, 20(12):2791-2795. (in Chinese)
HADER O, DROR I, KOPEIKA N S. Numerical calculation of MTF for image motion:experimental verification [J]. SPIE, 1992, 1697:183-197.
薛旭成, 傅瑶, 韩诚山. TDI CCD相机的卫星姿态稳定度确定 [J]. 中国光学, 2013, 6(5):767-772. XUE X CH, FU Y, HAN CH SH. Confirmation of satellite attitude stabilization for TDI CCD camera [J]. Chinese Optics, 2013, 6(5):767-772. (in Chinese)
MARIUS T, MEJDI T, MARKKU V. Motion Blur Identification Based On Differently Exposed Images . IEEE International Conference on Image Processing, Atlanta, IEEE, 2006:2021-2024.
TIMONER S J, FREEMAN D M. Multi-image gradient-based algorithms for motion estimation [J]. Optical Engineering, 2001, 40(9):2003-2016.
孙阳, 薛栋林, 郑立功, 等. 航天器平台在轨振动对遥感成像质量的影响 [J]. 光学技术, 2013, 6:553-558. SUN Y, XUE D L, ZHENG L G, et al.. Satellite platform on-orbit vibration's influence to image quality of remote sensing [J]. Optical Technique, 2013, 6:553-558. (in Chinese)
郭疆, 龚大鹏, 朱磊, 等. 测绘相机焦平面CCD交错拼接中重叠像元数计算 [J]. 光学 精密工程, 2013, 21(5):1251-1257. GUO J, GONG D P, ZHU L, et al.. Calculation of overlapping pixels in interleaving assembly of CCD focal plane of mapping camera [J]. Opt. Precision Eng. , 2013, 21(5):1251-1257. (in Chinese)
宁永慧, 郭永飞. TDICCD拼接相机的像元响应非均匀性校正方法 [J]. 中国光学, 2013, 6(3):386-394. NING Y H, GUO Y F. Correction of pixel response non-uniformityin TDICCD mosaic camera [J]. Chinese Optics, 2013, 6(3):386-394. (in Chinese)
顾学海, 王利平, 顾国华. 基于灰度投影改进的电子稳像 [J]. 应用光学, 2013, 6:957-963. GU X H, WANG L P, GU G H. Electronic image stabilization based on improved gray projection [J]. Journal of Applied Optics, 2013, 6:957-963. (in Chinese)
MAHENX J, CRUIKSHANK J, SEVIGNY L. Video-rate image stabilization system [J]. SPIE, 2000, 3414:232-238.
WU J G, ZHENG Z Z, FENG H J, et al.. Restoration of TDI camera images with motion distortion and blur [J]. Optics & Laser Technology, 2010, 42:1198-1203.
HADAR O, DROR I, KOPEIKA N S. Numerical calculation of image motion and vibration modulation transfer function—a new method [J]. SPIE, 1991, 1533:61-74.
HADAR O, DROR I, KOPEIKA N S. Image-resolution limits resulting from mechanical vibrations, Part IV:real-time numerical calculation of optical transfer-functions and experimental verification [J]. Optical Engineering, 1994, 33(2):566-78.