SUN Xiao, WANG Qi-ming, ZHU Ming etc. Application of optical fiber Bragg grating strain gauge to cable force monitoring of FAST[J]. Editorial Office of Optics and Precision Engineering, 2015,23(4): 919-925
SUN Xiao, WANG Qi-ming, ZHU Ming etc. Application of optical fiber Bragg grating strain gauge to cable force monitoring of FAST[J]. Editorial Office of Optics and Precision Engineering, 2015,23(4): 919-925 DOI: 10.3788/OPE.20152304.0919.
Application of optical fiber Bragg grating strain gauge to cable force monitoring of FAST
To monitor the cable force of the cable-net supporting structure of the Five-hundred-meter Aperture Spherical radio Telescope( FAST) and to avoid the effect of traditional measuring methods on the cable-net supporting structure and the electromagnetic interference
this paper presents a method to obtain the cable force values indirectly. The method uses Fiber Bragg Grating(FBG) sensors to monitor the cable connector strain to measure the cable force indirectly. In the measurement
a FBG strain gauge was installed at the linear strain region of the cable connector axially by using a dedicated welded base
by which the adverse effect of welding directly on the performance of cable connector structure was avoided. A temperature compensation method was used to compensate the effect of temperature changes on the FBG stain gauge measurement. The correlation coefficients were acquired by the calibration of the cable prestressing process. The cable force monitored then was calculated from the calibrated relation in actual engineering applications. Test results indicate that the fitting linearity of the cable force and the cable connector strain is up to 0.98 and the Root Mean Square (RMS) error in practical measurement is 1.38 t. The relative error is better than 3% within the range of the cable force for the FAST. The method is characterized by no electromagnetic interference
simple wiring
good reliability and long duration. It has been successfully applied to the cable force monitoring of 316 typical cables of the supporting cable-net in the FAST project.
关键词
Keywords
references
唐炜, 史仪凯. Bragg光纤传感技术应用研究[J]. 光学精密工程, 2002.10(1):79-83. TANG W, SHI Y K. Optical fiber Bragg grating sensing technology [J]. Opt. Precision Eng., 2002, 10(1):79-83.(in Chinese)
MELTZ G. Formation of Bragg ratings in optical fibers by a transverse holographic method [J]. Opt. Lett., 1989, 14(15): 823-825.
YAO W Y, VENU G M A, CHAO W, et al.. Application of multiplexed FBG and PZT impedance sensors for health monitoring of rocks [J]. Sensors, 2008, 8:271-289.
王天昊, 兰春光. 基于光纤传感技术的预应力混凝土收缩徐变损失监测[J]. 仪表技术与传感器, 2014, 6:61-64. WANG T H, LAN CH G. Monitoring prestressing loss caused by shrinkage and creep of concrete based on optical fiber sensing technology [J]. Instrument Technique and Sensor, 2014, 6:61-64.(in Chinese)
LARISSA S, JOHN B, THOMAS G, et al.. Delamination detection and characterization of bridging tractions using long FBG optical sensors[J]. Science Direct, 2007, 38:2087-2096.
XU G Q, XIONG D Y. Applications of fiber Bragg grating sensing technology in engineering[J]. Chinese Optics, 2013, 6(3): 306-317. (in Chinese)
NAN R D. Five Hundred Meter Aperture Spherical Radio Telescope (FAST) [J]. Science in China: Series G:Physics Mechanics & Astronomy, 2006, 49(2):129-148
徐红清. 锚索测力计在唐河水电站改线公路滑坡治理工程中的应用[J]. 山西水利科技, 2013, 4(13):13-14. XU H Q. Application of anchor cable ergometer in landslide treatment engineering on rerouted highway of Tanghe hydroelectric power station [J]. Shanxi Hydrotechnics, 2013, 4(13):13-14.(in Chinese)
曹洪, 张奔牛, 黄月华. 基于振频法的索力监测系统的研究与应用[J]. 山西建筑, 2013, 39(9):142-145. CAO H, ZHANG B N, HUANG Y H. Research on cable force monitoring system based on vibration frequency method and its application [J]. Shanxi Architecture, 2013, 39(9):142-145.(in Chinese)
李居泽, 周痒天, 彭渝舒. 一种基于磁通量传感技术的预应力监测方法[J]. 城市建筑, 2013, 24:308-309. LI J Z, ZHOU Y T, PENG Y SH. A prestressed monitoring method on the basis of flux sensing technology [J]. Urbanism and Architecture, 2013, 24:308-309.(in Chinese)
王雯珍, 刘月明. FBG应变传感器温度交叉敏感补偿技术研究[J]. 光电技术应用, 2014, 29(2):51-56. WANG W ZH, LIU Y M. Research on temperature cross sensitivity compensation technology of FBG strain sensor[J]. Electro-Optic Technology Application, 2014, 29(2):51-56.(in Chinese)
MAASKANT R, ALAVIE T, MEASURES M R, et al.. Fiber optic Bragg grating sensors for bridge monitoring [J]. Cement and Concrete Composite, 1997, 19:21-33.
李玉龙, 胡勇涛. 光纤布拉格光栅在焊接监测中的应用[J]. 光学精密工程, 2013, 21(11):2803-2812. LI Y L, HU Y T. Application of optical fiber Bragg grating in welding monitoring [J]. Opt. Precision Eng., 2013, 21(11):2803-2812. (in Chinese)
陈丽娟, 贺明玲, 王坤. 光纤光栅传感器交叉敏感问题解决方案[J]. 数字通信, 2012, 6(4):15-17. CHEN L J, HE M L, WANG K. Solutions of optical fiber grating sensor cross sensitivity[J]. Digital Communication, 2012, 6(4):15-17. (in Chinese)
赵明富, 王念, 罗彬彬, 等. 可同时测量蔗糖浓度和温度的组合光纤光栅传感器[J]. 中国光学, 2014, 7(3):476-482. ZHAO M F, WANG N, LUO B B, et al.. Simultaneous measurement of temperature and concentration of sugar solution based on hybrid fiber grating sensor[J]. Chinese Optics, 2014, 7(3): 476-482.(in Chinese)
郭明金, 姜德生, 袁宏才. 两种封装的光纤光栅温度传感器的低温特性[J]. 光学精密工程, 2007, 15(3):324-330. GUO M J, JIANG D SH, YUAN H C. Low temperature properties of fiber Bragg grating temperature sensors with two package methods[J]. Opt. Precision Eng., 2007, 15(3):324-330. (in Chinese)
吴入军, 郑百林, 贺鹏飞, 等. 埋入式光纤布拉格光栅传感器封装结构对测量应变的影响[J]. 光学精密工程, 2014, 22(1):24-30. WU R J, ZHENG B L, HE P F, et al.. Influence of encapsulation structures for embedded fiber-optic Bragg grating sensors on strain measurement [J]. Opt. Precision Eng., 2014, 22(1):24-30. (in Chinese)