LIU En-chen, ZHANG Hong-peng, ZENG Lin etc. Detection system of small particles in hydraulic oil[J]. Editorial Office of Optics and Precision Engineering, 2015,23(10z): 396-402
LIU En-chen, ZHANG Hong-peng, ZENG Lin etc. Detection system of small particles in hydraulic oil[J]. Editorial Office of Optics and Precision Engineering, 2015,23(10z): 396-402 DOI: 10.3788/OPE.20152313.0396.
Detection system of small particles in hydraulic oil
To help the fault prediction and diagnosis of a hydracelic system
a simple and effective optical detection system was designed to detect rapidly small particles in hydraulic oil. The light blocking optical method was used in this paper
the microfluidic detection chip for hydraulic oil detection was designed and fabricated
and flow speed and the trajectory of oil in a focus area were simulated by ANSYS software. The experiments of particle detection
counting and particle concentration detection were performed in the optical detection system
the data and signal in the experiments were analyzed with optical detection principle. Experimental results indicate that the signal-to-noise ratio of 20
m particle is higher
and the counting of particles is realized by JAVA program. The amplitude of signal increases with increasing particle concentration
and the signal amplitude caused by 200010
-6
is 6 times as high as that caused by 10010
-6
. The miacrofluidic chip and the detection system designed in the paper realize the rapid detection of small particles with the diameter larger than 20
m in hydraulic oil
and the oil with different particle concentrations can be distinguished.
关键词
Keywords
references
ZHANG X M, ZHANG H P, SUN Y Q, et al.. Effects of eddy current within particles on the 3D solenoid microfluidic detection chip[J]. Applied Mechanics and Materials, 2013, 385:546-549.
张兴明,张洪朋,陈海泉,等. 微流体油液检测芯片分辨率-频率特性研究[J]. 仪器仪表学报, 2014(02):427-433. ZHANG X M, ZHANG H P, CHEN H Q, et al.. Study on the resolution-frequency characteristic of microfluidic oil detection chip[J]. Chinese Journal of Scientific Instrument, 2014(02):427-433.(in Chinese)
ZHANG H P, HUANG W, ZHANG Y D, et al.. Design of the microfluidic chip of oil detection[J]. Applied Mechanics and Materials, 2012, 117:517-520.
DU L, ZHU X, HAN Y, et al.. High throughput wear debris detection in lubricants using a resonance frequency division multiplexed sensor[J]. Tribology Letters, 2013, 51(3):453-460.
ZHANG H, CHON C H, PAN X, et al.. Methods for counting particles in microfluidic applications[J]. Microfluidics and nanofluidics, 2009, 7(6):739-749.
CUI L, ZHANG T, MORGAN H. Optical particle detection integrated in a dielectrophoretic lab-on-a-chip[J]. Journal of Micromechanics and Microengineering, 2002, 12(1):7.
曹放,张立平. 高性能光阻式颗粒计数仪的设计与实现[J]. 电子测量技术, 2014,04:130-133. CAO F, ZHANG L P. Design and implementation of high performance light-blockage particle counter[J]. Chinese Journal of Electronic Measurement Technology, 2014,04:130-133.(in Chinese)
DITTRICH P S, SCHWILLE P. An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles[J]. Analytical Chemistry, 2003, 75(21):5767-5774.
ROY P, BAL A, CHAKRABORTY T, et al.. Optical detection in Biochips:A fuzzy based detection analyzer for homogeneous samples in DMFBs[C]//Cyber Technology in Automation, Control, and Intelligent Systems(CYBER), 2014 IEEE 4th Annual International Conference on. IEEE, 2014:551-556.
苑伟政,焦文龙,常洪龙. 微流控的系统级设计[J]. 光学 精密工程,2013,12:3141-3151. FAN W ZH, JIAO W L, CHANG H L. System level design of microfluidics[J].Chinese Journal of Optical and Precision Engineering, 2013,12:3141-3151.(in Chinese)
林炳承,秦建华. 微流控芯片实验室[J]. 色谱.2005(9):456-463. LIN B CH,QIN J H. Laboratory on a Microfluidic Chip[J]. Chinese Journal of Chromatography, 2005(9):456-463.
徐征,王继章,杨铎,等. 辅助溶剂对PMMA微流控芯片模内键合的影响[J]. 光学 精密工程,2012(2):321-328. XU ZH, WANG J ZH, YANG D, et al.. Effect of assistant solvent on in-mold bonding of PMMA microfluidic chips[J]. Chinese Journal of Optical and Precision Engineering, 2012(2):321-328.(in Chinese)
徐涛,高玉成,武星. 对于光阻法在对小粒径微粒检测时的原理分析[J]. 仪器仪表学报,2005(1):13-16+22. XU T,GAO Y C,WU X. Analysis of Light-blockage Principle in Smal l Particle Size Measurement[J].Chinese Journal of Scientific Instrument,2005(1):13-16+22.