Elliptically curved crystal spectrometers exhibit large width of spectral measurement
high resolution of energy spectrum and other features
thus can be fully used in the experimental research on "SG Ⅱ" Inertial Confinement Fusion (ICF). Taking advantage of X-ray tube of the copper (Cu) target for the X-ray diffractometer
and seleting appropriate thickness of filter disc to restrain Cu-Kβ ray and bremsstrahlung
parameters of integral diffraction efficiency and full width at half maximum of rocking curve for elliptically curved quartz crystal which was made from silicon dioxide at the Cu-Kα energy point were measured. In addition
a verification test aiming at the changes of curvature radius for curved crystal with the two above mentioned important parameters were performed
thus estimating the resolution of energy spectrum. The result shows that the integral diffraction efficiency of the elliptically curved crystal and full width at half maximum of rocking curve are sensitive to the change of the bending radius of the crystal. Therefore
the mosaic effect of crystal can be strengthened by improving the tortuosity of the crystal. The result can provide data support for further optimization of multi-purpose elliptical curved crystal spectrometer and quantitative measurement of X-ray spectrum.
关键词
Keywords
references
DE MICHELIS C, MATTIOLI M. Soft-X-ray spectroscopic diagnostics of laboratory plasmas[J]. Nuclear Fusion, 1981, 21(6): 677-754.
BASOV N G, GOETZ K, KALASHNIKOV M P, et al.. Investigation of laser plasma dynamics using the X-ray spectra of multicharged ions[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1985, 9(4): 773-780.
CHEN J ZH, MA R L, CHEN ZH Y, et al.. Enhancement effect of carbon chamber confinement on laser plasma radiation[J]. Opt. Precision Eng., 2013, 21(8): 1942-1948. (in Chinese)
GUO K M, GAO X, HAO Z Q, et al.. The fluorescence feature of plasma induced by femtosecond laser pulses in air[J]. Acta Physica Sinica, 2012, 61(7): 075212. (in Chinese)
EVANS K D, LEIGH B. The absolute calibration of the reflection integral of Bragg X-ray analyser crystals-single reflection methods[J]. Space Science Instrumentation, 1976, 2: 105-123.
GILFRICH J V, BROWN D B, BURKHALTER P G, et al.. Integral reflection coefficient of X-ray spectrometer crystal[J]. Applied Spectroscopy, 1975, 29(4): 322-326.
MARRS R E, BROWN G V, EMIG J A, et al.. System for calibrating the energy-dependent response of an elliptical Bragg-crystal spectrometer[J]. Review of Scientific Instruments, 2014, 85(11):11D626.
WEI M X, YANG J M, YANG G H. Calibration of integral diffraction coefficient of flat crystal[J]. High Power Laser and Particle Beams, 2006, 18(2): 219-222. (in Chinese)
GAN X SH, YANG J M, YI R Q, et al.. Experimental research on integral diffraction coefficient of RAP crystal[J]. Acta Photonica Sinica, 2009, 38(4): 947-950. (in Chinese)
WEI M X, YANG G H, YI T, et al.. Calibration research of integral diffraction efficiency of crystal in laboratory[J]. Acta Optica Sinica, 2012, 32(7): 0730002. (in Chinese)
WANG R R, CHEN W M, WANG W. Improvement of spectral resolution power for an elliptically curved crystal spectrometer[J]. Opt. Precision Eng, 2010, 18(6): 1303-1308. (in Chinese)