LIU Yu-juan, CUI Ji-cheng, ZHANG Liu etc. Design and analysis of concave grating concentric spectrometer with shifting object and image plane[J]. Editorial Office of Optics and Precision Engineering, 2017,25(10s): 1-6
LIU Yu-juan, CUI Ji-cheng, ZHANG Liu etc. Design and analysis of concave grating concentric spectrometer with shifting object and image plane[J]. Editorial Office of Optics and Precision Engineering, 2017,25(10s): 1-6 DOI: 10.3788/OPE.20172513.0001.
Design and analysis of concave grating concentric spectrometer with shifting object and image plane
The object plane and image plane of concave grating concentric spectrometers are in the same plane
and the vertical axis distance between object and image is only a few millimeters
which limits the arrangement of focal plane detectors and front lens. In order to solve this problem
a plane mirror was introduced into the optical system to deflect the light
and the separation of the object surface and the image surface was realized. According to the deflection light
two improved concave grating concentric spectrometers with shift object plane or shift image plane were designed and then simulated by simulation software. The simulation results show that the two spectrometers can achieve the separation of object surface and image plane
the separation distance is greater than 16 mm
and the aberrations are also well controlled
within the 400-800 nm the aberration curve is almost zero. Those results meet the application requirements of low aberration
high image quality
image plane separation
which can effectively solve the problem of device arrangement.
关键词
Keywords
references
LOBB D R. Imaging spectrometers using concentric optics[J]. SPIE, 1997, 3118:339-347.
BAUDIN G, BESSUDO R, BEZY J L, et al.. Medium resolution imaging spectrometer (MERIS), in Future European and Japanese Remote-Sensing Sensors and Programs[J]. Proc. Soc. Photo-Opt. Instrum. Eng., 1991,1490:102-113.
MOUROULIS P, GREEN R O, WILSON D W.Optical design of a coastal ocean imaging spectrometer[J]. Opt. Express, 2008,16:9087-9095.
ROBERT O, GREEN, MICHAEL L, et al.. Imaging spectroscopy and the airborne visible/infrared imaging spectrometer(AVIRIS)[J]. Remote Sens. Environ., 1998,65:227-248.
FRANCESCO D, JENS N, BENJAMIN K, et al..Improving radiometry of imaging spectrometers by using programmable spectral regions of interest[J]. Photogrammetry and Remote Sensing, 2009,64:631-639.
PAINTER T H, ROBERTS D A, GREEN R O, et al..The effect of grain size on spectral mixture analysis of snow-covered area from AVIRIS data[J]. Remote Sensing of Environment, 1998,65:320-332.
MOUROULIS P.Optical design of a coastal ocean imaging spectrometer[J]. Opt. Express, 2008,16:9087-9095.
MOUROULIS P,THOMADS D A.Spectral response evaluation and computation for pushbroom imaging spectrometers[J]. SPIE,2007, 66670G:1-12.
MOUROULI P. Grating fabrication through X-ray lithography[J]. SPIE,2003, 5173:108-114.
ALEXANDER F GOETZ H.Three decades of hyperspectral remote sensing of the earth:A personal view, remote sensing of environment[J].2009,113:5-16.
DYSON J.Unit magnification optical system without Seidel aberrations[J]. J. Opt.Soc. Am., 1959, 49:713-716.
NAMIOKA T.Theory of the concave grating I[J]. J. Opt. Soc. Am., 1959, 49(5):446-460.
LOBB D R. Theory of concentric designs for grating spectrometers[J]. Appl. Opt., 1994, 33, 2648-2658.
LOBB D R.Imaging spectrometers using concentric optics[J]. SPIE, 1997, 3118, 339-347.
FISHER J, ANTONIADES J A, ROLLINS C, et al..Hyperspectral imaging sensor for the coastal environment[J]. SPIE, 1998, 3482:179-186.
MOUROULIS P, GREEN R O, CHRIEN T G.Design of pushbroom imaging spectrometer for optimum recovery of spectroscopic and spatial information[J]. Applied Optics, 2000,13:39-44.
FRANCESCO D, JENS N, BENJAMIN K, et al.. Improving radiometry of imaging spectrometers by using programmable spectral regions of interest[J]. Photogrammetry and Remote Sensing, 2009,64:631-639.
吴国安. 光谱仪器设计[M]. 北京:科学出版社,1978. WU G A. Design of Spectrometer[M].Beijing:Science Press,1978. (in Chinese)
LIU Y G,WANG C M,LIN J. Optimal designing of light folding imaging spectrometer based on dyson concentric system[J]. Spectroscopy and Spectral Analysis,2016, 32(7):2286-2290.