DONG Tao, NI Jin-ping, ZENG Xiang-wei etc. Signal processing for double objectives to impact simultaneously on single linear CCD vertical target[J]. Editorial Office of Optics and Precision Engineering, 2017,25(10s): 266-273
DONG Tao, NI Jin-ping, ZENG Xiang-wei etc. Signal processing for double objectives to impact simultaneously on single linear CCD vertical target[J]. Editorial Office of Optics and Precision Engineering, 2017,25(10s): 266-273 DOI: 10.3788/OPE.20172513.0266.
Signal processing for double objectives to impact simultaneously on single linear CCD vertical target
Currently several coordinate measurement methods for bullets to impact could not be used in the situation for two bullets to impact simultaneously
thus CCD vertical target measurement system of single linear array composed of components such as a CCD camera based on single black-and-white linear array
a double hyphen line laser and projection plank
etc was adopted to overcome the problem that measurement for double objectives to impact could not be achieved in traditional coordinate measurement method for bullets to impact. Theoretical analysis and actual handling were conducted on signal of double objectives captured by CCD vertical measurement system of single linear array and recognition was conducted on three different types of signals of double objectives according to two different signal feature including grey value of bullet signal and pixel width value of occupied CCD device. Feasibility and measurement precision of the system were verified through the method to simulate live ammunition verification and feasibility of signal handling method of double objectives was proved; standard deviations and of measurement error of coordinate
σ
x
and coordinate
σ
y
are respectively 2.0 mm and 6.8 mm when target surface is 0.5 m×1 m.
关键词
Keywords
references
MCCARTHY B D, REGAN B J. Position measuring apparatus and method:USA 4885725[P].1989-12-05.
KNIGHT L C, PHILIPS R B, BOWYER W H, et al.. Projectile position detection apparatus[P]. USA:4350881,1982-09-21.
SMITH C L, LI D G. A forensic ballistics projectile location system[J]. IEEE, 1998,98(5):184-189.
LU S T, CHOU C, LEE M C, et al.. Electro-optics target system for position and speed measurement[J]. IEE Proceedings-A, 1993, 140(4):252-256.
何凯平,徐达,李华.大面积三角组合光幕弹幕武器密集度的高精度测试[J]. 光学精密工程,2015,23(6):1523-1529. HE K P, XU D, LI H. High precision measurement for barrage weapon dispersion based on large area triangle composite light-screens[J]. Opt. Precision Eng.,2015,23(6):1523-1529. (in Chinese)
LLUNA E, SANTIAGO V, DEFEZ B, et al.. Velocity vector (3D) measurement for spherical objects using an electro-optical device[J]. Meas J Int Meas Confed, 2011,44(9):1723-1729.
SCHOFFLER M S, CHULUUNBAATAR O, HOUAMER S, et al.. Two-dimensional electron-momentum distributions for transfer ionization in fast proton-helium collisions[J]. Physical Review A-Atomic, Molecular, and Optical Physics, 2013,88(4):42-45.
CHANG C C, CHANG H C, TANG L C, et al.. Hybrid-integrated prism array optoelectronic targeting system[J]. Optical Laser Technology, 2005, 37(8):591-596.
于纪言,李永新,王晓鸣.单列光源反射式光幕靶检测弹着点[J]. 光学精密工程,2010,18(6):1354-1360. YU J Y, LI Y X,WANG X M. Measurement of impact points using reflective light screen target of single column light source[J]. Opt. Precision Eng.,2010,18(6):1354-1360. (in Chinese)
王苗,李华.CCD立靶测量系统目标捕获性能研究[J]. 光子学报, 2009,38(6):1539-1542. WANG M, LI H. Capturing of CCD vertical target measurement system[J]. Acta Photonica Sinica,2009,38(6):1539-1542.(in Chinese)
张林,李永新,陈运生. TDI-CCD光靶弹着点坐标测量误差分析[J]. 弹道学报, 2008,20(4):20-23. ZHANG L, LI Y X, CHEN Y SH. Analysis of coordinate measuring error based on TDI-CCD optical target[J]. Journal of Ballistics,2008,20(4):20-23.(in Chinese)
武江鹏,宋萍,郝创博,等. 带弹序的弹幕武器立靶密集度测试[J]. 光学精密工程,2016,24(3):600-608. WU J P, SONG P, HAO CH B, et al.. Measurement of vertical target dispersion with target-hitting sequence for barrage weapons[J]. Opt. Precision Eng.,2016,24(3):600-608. (in Chinese)
DONG T, HUA D X, LI Y, et al.. Measuring principle of vertical target density based on single linear array CCD camera[J]. Optik, 2014, 125:176-178.
董涛,华灯鑫,李言,等. 一种单线阵CCD立靶系统参数标定方法[J]. 西安理工大学学报, 2015,31(1):19-24. DONG T, HUA D X, LI Y, et al.. Calibration Method for Parameter of ingle-Linear Array CCD Vertical Target System[J]. Journal of Xi'an University of Technology,2015,31(1):19-24. (in Chinese)