CHEN Qin-fang, MA Zhen, WANG Hu etc. High-precision test station for stray light based on point source transmittance[J]. Editorial Office of Optics and Precision Engineering, 2017,25(12z): 39-44
CHEN Qin-fang, MA Zhen, WANG Hu etc. High-precision test station for stray light based on point source transmittance[J]. Editorial Office of Optics and Precision Engineering, 2017,25(12z): 39-44 DOI: 10.3788/OPE.20172514.0039.
High-precision test station for stray light based on point source transmittance
The increased demand for detection of dim targets in deep space and the rapid development of low threshold space-based sensors have required greater suppression performance of stay light and higher test accuracy. A stray light test station based on Point Source Transmittance (PST) is built. The station allows an measuring aperture up to 1 m and waveband from the visible to the infrared. In the station
the turntable instrument is allowed to scan ±110° in azimuth
and ±15° in picth. The test station is all black with dimensions of 28 m×8 m×9 m. In order to control light scattered from the collimator
the primary mirror with less than 2 nm RMS roughness is manufactured. A double cylindrical chamber is employed to direct and attenuate the scattered light from the system. In addition
a clean room in 1 000 class is utilized to filter air to reduce light scattered from particles in the air. Analysis and measurements show that the test station can measure point PST as low as 10
-7
at visible wavelengths
and 10
-6
at infrared wavelengths. Its test accuracy|lg(measurement value/true value)|is less than 0.5.
关键词
Keywords
references
王一凡, 李零印. 白天观测空间目标的恒星光电探测系统的杂散光抑制[J]. 光学精密工程, 2011, 19(12):2854-2861. WANG Y F, LI L Y. Stray light suppression of star photoelectric detection system for space target in daytime[J]. Opt. Precision Eng., 2011, 19(12):2854-2861. (in Chinese)
杨林, 李达, 崔天刚, 等. 空间太阳望远镜在紫外波段成像检测中的杂散光测量和消除[J]. 光学精密工程, 2011, 19(7):1456-1463. YANG L, LI D, CUI T G, et al.. Measurement and elimination of stray light from space solar telescopes for imaging test at UV band[J]. Opt. Precision Eng., 2011, 19(7):1456-1463. (in Chinese)
JOHN L S. Stray Light Comparison of Off-axis and On-axis Telescopes[D]. UT:Utah State University, 2000.
钟兴, 贾继强. 空间相机消杂光设计及仿真[J]. 光学精密工程, 2009, 17(3):621-625. ZHONG X, JIA J Q. Stray light removing design and simulation of spaceborne camera[J]. Opt. Precision Eng., 2009, 17(3):621-625. (in Chinese)
李晓平, 王钢, 胡亭亮. 高精度杂散光测量系统分析[J]. 红外技术, 2011, 33(9):521-524. LI X P, WANG G, HU T L. High-precision stray light measurement system analysis[J]. Infrared Technology, 2011, 33(9):521-524. (in Chinese)
PETERSON G L. Stray light test station for measuring point source transmission and thermal background of visible and infrared sensors[J]. SPIE, 2008, 7069:70690M.
MAZY E, STOCKMAN Y, HELLIN M L. Design and modelisation of a straylight facility for space optical instrument[J]. SPIE, 2012, 8550:855007.
KEMP J C, STAUDER J L, TURCOTTE S B, et al.. Terrestrial black hole for measuring high-rejection off-axis response[J]. SPIE, 1997, 3122:45-46.
GROCHOCKI F, FLEMING J. Stray light testing of the OLI telescope[J]. SPIE, 2010, 7794:77940W.
王治乐, 龚仲强, 张伟, 等. 基于点源透过率的空间光学系统杂光测量[J]. 光学技术, 2011, 37(4):401-405. WANG ZH L, GONG ZH Q, ZHANG W, et al.. Measurement of stray light based on point-source transmittance in space optical system[J]. Optical Technique, 2011, 37(4):401-405. (in Chinese)