Song CHEN, Shu-yun WANG, Xin-yi XIE, et al. Practical research on computer chip water cooling system with combined piezoelectric pump unit[J]. Optics and precision engineering, 2018, 26(5): 1140-1147.
DOI:
Song CHEN, Shu-yun WANG, Xin-yi XIE, et al. Practical research on computer chip water cooling system with combined piezoelectric pump unit[J]. Optics and precision engineering, 2018, 26(5): 1140-1147. DOI: 10.3788/OPE.20182605.1140.
Practical research on computer chip water cooling system with combined piezoelectric pump unit
maintainability and the cooling efficiency of piezoelectric computer chip water cooling system
a computer chip water cooling system driven by combined piezoelectric pump was proposed. Initially
the output performance of the combined pump units in piezoelectric water-cooling system with different combinations (series/parallel)
pump quantity and the relative position were tested and analyzed under 220 Vpp square wave. Subsequently
a research on water cooling efficiency of piezoelectric water-cooling system was conducted
based on the experimental results of combined pump units. The experimental results indicated that as the double pump units working in series combination
the performance of the working units located at the first and tail position (AD) was optimal with maximum output pressure (25 kPa) at a frequency of 30 Hz. When four pump units were working in series combination
the maximum pressure (23.5 kPa) and maximum flow (13.5 mL/min) were obtained at 35 Hz and 55 Hz
respectively. While double pump units were working in parallel combination
the performance of the double-working pumps which were located at the first (AC) position was relatively poor; When four pump units were working in parallel combination
the maximum output flow (22 mL/min) and maximum output pressure (12.6 kPa) were obtained at 50Hz and 60Hz
respectively
through switching of series/parallel and the pump quantity. It was found that different combinations and pump quantities could acquire different cooling efficiency. The driving parameters of the combined piezoelectric cooling system are obtained
which provide a novel approach for the effective cooling of computer chips.
关键词
Keywords
references
LIU D, ZHAO F Y, YANG H X, et al ..Thermoelectric mini cooler coupled with micro thermosiphon for CPU cooling system[J]. Energy , 2015, 83:29-36.
PUTRA N, SEPTIADI W N. Improvement of heat pipe performance through integration of a coral biomaterial wick structure into the heat pipe of a CPU cooling system[J]. Heat and Mass Transfer , 2017, 53(4):1163-1174.
AL-RASHED M H, DZIDO G, KORPYS' M, et al .. Investigation on the CPU nanofluid cooling[J]. Microelectronics Reliability , 2016, 63:159-165.
CHEN S, LIU Y, KAN J W, et al ..Influence of pump-chamber height on bubble retention in piezoelectric micro-pump[J]. Opt. Precision Eng ., 2017, 25(3):672-679. (in Chinese)
ZENG P, CHENG G M, LIU J L, et al .. Practical research on water cooling system with computer chip driven by PZT pump[J]. Piezoelectrics & Acoustooptics , 2006, 28(4):403-406. (in Chinese)
PENG T J, YANG ZH G, KAN J W. Investigation on piezo-pump used in water-cooling-system for computer CPU chip[J]. Journal of Refrigeration , 2009, 30(3):30-34. (in Chinese)
ZHANG ZH H, KAN J W, WANG S Y, et al .. Effects of driving mode on the performance of multiple-chamber piezoelectric pumps with multiple actuators[J]. Chinese Journal of Mechanical Engineering , 2015, 28(5):954-963.
ZHAO T, YANG ZH G, LIU J F, et al .. Controlled synthesis of gold nanoparticles based on PZT micropump and pulsating mixing[J]. Opt. Precision Eng ., 2014, 22(4):904-910. (in Chinese)
ZENG P, LI L A, XU F, et al .. Structural-fluid coupling simulation and experimental verification on valveless piezoelectric pump[J]. Opt. Precision Eng ., 2016, 24(1):112-118. (in Chinese)
MA Y T, WANG C, YAN X T, et al .. Note:A valve-type piezoelectric reciprocating pump with secondary resonant vibrator[J]. Review of Scientific Instruments , 2016, 87(1):016104.
章熙民, 朱彤, 安青松, 等.传热学[M]. 6版.北京:中国建筑工业出版社, 2014.
ZHANG X M, ZHU T, AN Q S, et al.. Heat Transfer [M]. 6th ed. Beijing:China Architecture & Building Press, 2014. (in Chinese)
WANG SH Y, KAN J W, SHENG H Q, et al .. Design, fabrication and test of serial-connection 5-chamber piezoelectric pump[J]. Nanotechnology and Precision Engineering , 2012, 10(5):406-411. (in Chinese)