Direct determination of relative wavelength response of DFB lasers in sinusoidal scanning wavelength modulation spectra based on current scanning wavelength response function
Modern Applied Optics|更新时间:2020-08-13
|
Direct determination of relative wavelength response of DFB lasers in sinusoidal scanning wavelength modulation spectra based on current scanning wavelength response function
Optics and Precision EngineeringVol. 27, Issue 11, Pages: 2281-2288(2019)
Song-jie GUO, Jian-xin LIU, Yue-ting ZHOU, et al. Direct determination of relative wavelength response of DFB lasers in sinusoidal scanning wavelength modulation spectra based on current scanning wavelength response function[J]. Optics and precision engineering, 2019, 27(11): 2281-2288.
DOI:
Song-jie GUO, Jian-xin LIU, Yue-ting ZHOU, et al. Direct determination of relative wavelength response of DFB lasers in sinusoidal scanning wavelength modulation spectra based on current scanning wavelength response function[J]. Optics and precision engineering, 2019, 27(11): 2281-2288. DOI: 10.3788/OPE.20192711.2281.
Direct determination of relative wavelength response of DFB lasers in sinusoidal scanning wavelength modulation spectra based on current scanning wavelength response function
In order to identify a method suitable for describing the Relative Wavelength Response (RWR) in the sine wave scanning wavelength modulation spectrum
and to improve the accuracy of the sinusoidal scanning measurement of gas concentration
existing methods for describing the RWR of the laser are discussed. First
several existing methods for describing the wavelength response of a laser for sinusoidal scanning are analyzed. Then
the RWR simulated by the different methods and the residuals of the measured laser wavelength response are compared. The smaller the residual
the more accurate the wavelength response of the laser. Finally
the carbon dioxide gas concentration is measured in a precise and accurate manner. The experimental results show that the method of directly determining the RWR by the current scanning wavelength response describes the laser wavelength response more accurately. The RWR obtained is compared with the results measured by the etalon
and the standard deviation of the residuals is less than 5×10
-3
cm
-1
. By combining this method with multichannel cell technology and calibration-free wavelength modulation technology
the accuracy of the method was verified by measuring the concentration of carbon dioxide gas.
关键词
Keywords
references
LEWICKI R, DOTY J H, CURL R F, et al .. Ultrasensitive detection of nitric oxide at 5.33 m by using external cavity quantum cascade laser-based Faraday rotation spectroscopy[J]. Proceedings of the National Academy of Sciences , 2009, 106(31): 12587-12592.
RIEKER G B, JEFFRIES J B, HANSON R K, et al .. Diode laser-based detection of combustor instabilities with application to a scramjet engine[J]. Proceedings of the Combustion Institute , 2009, 32(1): 831-838.
ZHANG ZH R, XIA H, DONG F ZH, et al .. Simultaneous and on-line detection of multiple gas concentration with tunable diode laser absorption spectroscopy[J]. Opt. Precision Eng. , 2013, 21(11): 2771-2777. (in Chinese)
LI H J. Near-infrared Diode Laser Absorption Spectroscopy with Applications to Reactive Systems and Combustion Control [D]. Palo Alto: Stanford University, 2007.
ZHAO G, TAN W, JIA M Y, et al .. Intensity-stabilized fast-scanned direct absorption spectroscopy instrumentation based on a distributed feedback laser with detection sensitivity down to 4×10 -6 [J]. Sensors , 2016, 16(9): 1544-1554.
WERLE P, MVCKE R, SLEMR F. The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS)[J]. Applied Physics B Photophysics and Laser Chemistry , 1993, 57(2): 131-139.
RIEKER G B, JEFFRIES J B, HANSON R K. Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments[J]. Applied Optics , 2009, 48(29): 5546-5560.
ZHENG SH G, LI M, ZHANG J, et al .. Design and implementation of trace N 2 O detection system[J]. Opt. Precision Eng ., 2012, 20(10): 2154-2160. (in Chinese)
LI Y P, ZHANG G J, LI Q B, et al .. Infrared CO 2 gas sensor based on space double beams and its measurement module[J]. Opt. Precision Eng. , 2009, 17(1):14-19. (in Chinese)
FUKUDA M, MISHIMA T, NAKAYAMA N, et al .. Temperature and current coefficients of lasing wavelength in tunable diode laser spectroscopy[J]. Applied Physics B , 2010, 100(2): 377-382.
PETERMANN K. Laser Diode Modulation and Noise [M]. Netherlands: Kluwer Academic Publisher, 1988.
SUN K, CHAO X, SUR R, et al .. Analysis of calibration-free wavelength-scanned wavelength modulation spectroscopy for practical gas sensing using tunable diode lasers[J]. Measurement Science and Technology , 2013, 24(12): 125203-125215.
QU Z C, GHORBANI R, VALIEV D, et al .. Calibration-free scanned wavelength modulation spectroscopy-application to H 2 O and temperature sensing in flames[J]. Optics Express , 2015, 23(12): 16492-16499.
QU Z C, SCHMIDT F M. In situ H2O and temperature detection close to burning biomass pellets using calibration-free wavelength modulation spectroscopy[J]. Applied Physics B , 2015, 119(1): 45-53.
ZHAO G, TAN W, HOU J J, et al .. Calibration-free wavelength-modulation spectroscopy based on a swiftly determined wavelength-modulation frequency response function of a DFB laser[J]. Optics Express , 2016, 24(2): 1723-1733.
LIU J X, ZHOU Y T, MA W G, et al .. A novel methodology to directly pre-determine the relative wavelength response of DFB laser in wavelength modulation spectroscopy[J]. Opt. Expr. , 2019, 27 (2): 1249-1261.
BASS M. Handbook of Optics [M]. America: McGraw-Hill Education, 2009.
Online laser absorption spectroscopy detection of trace ethylene in coal pyrolysis
Related Author
DUAN Zheng
MENG Xingxing
LI Kailiang
SUN Xiaocong
TIAN Yali
GONG Ting
LI Chuanliang
QIU Xuanbing
Related Institution
School of Applied Science, Taiyuan University of Science and Technology, Shanxi Precision Measurement and Online Testing Equipment Engineering Research Center, Shanxi Province Light Field Regulation and Integration Application Technology Innovation Center, Taiyuan University of Science and Technology
College of Physics and Electronic Engineering, Jiangsu Normal University